Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Removal of Microorganisms in Drinking Water using Pulsed High Voltage

Journal of Engineering and Technological Sciences · Vol. 45 No. 1 (2014) · hlm. 1–8

DOI
10.5614/j.eng.technol.sci.2013.45.1.1
ISSN
2338-5502, 2337-5779
Terbit
2014-04-01
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

A pulsed high voltage was used to remove microorganisms in drinking water. The effects of the pulsed high voltage on pH, conductivity, temperature and oxidation reduction potential (ORP) of the drinking water were investigated. The observed results show that the removal efficiency with respect to fecal coliforms and total coliforms increased with the increase of the pulsed high voltage. The removal efficiency for microorganisms such as fecal coliforms and total coliforms was in the range 25-100% and 44-100%, respectively, after the water was exposed to a pulsed high voltage of 5-10 kV for 60 minutes. An increase of the pulsed high voltage caused a decrease in the conductivity and ORP with operational time.

Jaringan kolaborasi para penulis

38 penulis · 99 tautan kepenulisan bersama · 36 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Gifu University
  • Universitas Bung Hatta
  • Universitas Borobudur
  • Sumatera Institute of Technology
  • University of Technology Malaysia
  • National Nuclear Energy Agency of Indonesia
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Aulia AuliaAndalas University8
Primas EmeraldiAndalas University7
Fusheng LiGifu University4
Novizon NovizonAndalas University4
YulastriAfiliasi tidak diketahui2
Dean CorioSumatera Institute of Technology2
Zulkurnain Abdul‐MalekUniversity of Technology Malaysia2
Abdul RajabAndalas University2
Faisyal RazakAndalas University2
Fu-Sheng LiAfiliasi tidak diketahui1
Toshiro YamadaGifu University1
Hongjie GuiGifu University1
Yongfen WeiGifu University1
Syukri AriefAndalas University1
Ellyta SariUniversitas Bung Hatta1
Zulhadjri ZulhadjriAndalas University1
Matlal Fajri AlifAndalas University1
Maulana Yusup RosadiUniversitas Borobudur1
Hanalde AndreAndalas University1
Agus Rahmad TimorAndalas University1
Zulka HendriAndalas University1
Andrew Kurniawan VadreasAndalas University1
Syaifa MulyadiAndalas University1
Roan AlfajriAndalas University1
Baharudin BaharudinAndalas University1
Darmawan DarmawanNational Nuclear Energy Agency of Indonesia1
Amirul LuthfiAndalas University1
Budi SunaryoUniversitas Bung Hatta1
Dasrinal TessalUniversitas Jambi1
Abdul ManabAndalas University1
Muhammad KodratAndalas University1
Gusvita WidiaAndalas University1
Mondrizal MondrizalAndalas University1
Tesya Uldira SeptiyeniAndalas University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Removal of Microorganisms in Drinking Water using Pulsed High Voltage</dc:title>
	<dc:creator>Hazmi, Ariadi</dc:creator>
	<dc:creator>Desmiarti, Reni</dc:creator>
	<dc:creator>Waldi, Eka Putra</dc:creator>
	<dc:creator>Darwison, D.</dc:creator>
	<dc:description xml:lang="en-US">A pulsed high voltage was used to remove microorganisms in drinking water. The effects of the pulsed high voltage on pH, conductivity, temperature and oxidation reduction potential (ORP) of the drinking water were investigated. The observed results show that the removal efficiency with respect to fecal coliforms and total coliforms increased with the increase of the pulsed high voltage. The removal efficiency for microorganisms such as fecal coliforms and total coliforms was in the range 25-100% and 44-100%, respectively, after the water was exposed to a pulsed high voltage of 5-10 kV for 60 minutes. An increase of the pulsed high voltage caused a decrease in the conductivity and ORP with operational time.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2014-04-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/612</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2013.45.1.1</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 45 No. 1 (2013); 1-8</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/612/333</dc:relation>
</oai_dc:dc>