Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Modeling Effects on Forces in Shear Wall-Frame Structures*

Journal of Engineering and Technological Sciences · Vol. 47 No. 2 (2015) · hlm. 117–125

DOI
10.5614/j.eng.technol.sci.2015.47.2.1
ISSN
2338-5502, 2337-5779
Terbit
2015-05-31
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

Shear walls are added to a structural system to reduce lateral deformations in moment resisting frames and are designed to carry a major portion of lateral load induced by an earthquake. A small percentage error in the shear wall calculation will have a significant effect on the frame forces. The results show that even a slight difference in structural assumption, or modeling, results in significant differences. Some of these differences are beyond the values that are covered by safety factors for errors in modeling. The differences are more obvious in the upper stories. It is not recommended to overestimate shear wall stiffness, nor underestimate frame stiffness.

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Modeling Effects on Forces in Shear Wall-Frame Structures*</dc:title>
	<dc:creator>Surahman, Adang</dc:creator>
	<dc:description xml:lang="en-US">Shear walls are added to a structural system to reduce lateral deformations in moment resisting frames and are designed to carry a major portion of lateral load induced by an earthquake. A small percentage error in the shear wall calculation will have a significant effect on the frame forces. The results show that even a slight difference in structural assumption, or modeling, results in significant differences. Some of these differences are beyond the values that are covered by safety factors for errors in modeling. The differences are more obvious in the upper stories. It is not recommended to overestimate shear wall stiffness, nor underestimate frame stiffness.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2015-05-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/1436</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2015.47.2.1</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 47 No. 2 (2015); 117-125</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/1436/903</dc:relation>
</oai_dc:dc>