Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Switching Control Strategy for Greenhouse Temperature-Humidity System Based on Prediction Modeling: A Simulation Study

Journal of Engineering and Technological Sciences · Vol. 49 No. 5 (2017) · hlm. 689–703

DOI
10.5614/j.eng.technol.sci.2017.49.5.9
ISSN
2338-5502, 2337-5779
Terbit
2017-11-30
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

It is difficult to achieve coordination control of multiple facilities that are driven by on-off actuators in a greenhouse, especially when there is more than one indoor environmental factor to consider at the same time. With the consideration of indoor air temperature and relative humidity, we propose a switching control strategy based on prediction modeling. The operation of the greenhouse system was divided into several modes according to the on-off control characteristics of the available facilities. Then, a switching diagram was designed according to the relationship between the indoor air temperature and humidity and their setting ranges. When the two indoor environmental factors reach their upper or lower limits, IARX models are used to predict them over a specified horizon for each optional mode respectively. Mode switching is carried out based on prediction results. The switching control strategy was simulated based on a mechanistic model of the greenhouse microclimate. The results show that the facilities can be coordinated very well by the proposed control strategy and it is easy to implement. The control strategy is still applicative when more facilities or more indoor environmental factors need to be taken into account.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Southeast University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Switching Control Strategy for Greenhouse Temperature-Humidity System Based on Prediction Modeling:  A Simulation Study</dc:title>
	<dc:creator>Xu, Zhenfeng</dc:creator>
	<dc:creator>Chen, Junjie</dc:creator>
	<dc:subject xml:lang="en-US">agricultural greenhouse</dc:subject>
	<dc:subject xml:lang="en-US">hybrid system</dc:subject>
	<dc:subject xml:lang="en-US">prediction model</dc:subject>
	<dc:subject xml:lang="en-US">relative humidity</dc:subject>
	<dc:subject xml:lang="en-US">switching control</dc:subject>
	<dc:subject xml:lang="en-US">temperature.</dc:subject>
	<dc:description xml:lang="en-US">It is difficult to achieve coordination control of multiple facilities that are driven by on-off actuators in a greenhouse, especially when there is more than one indoor environmental factor to consider at the same time. With the consideration of indoor air temperature and relative humidity, we propose a switching control strategy based on prediction modeling. The operation of the greenhouse system was divided into several modes according to the on-off control characteristics of the available facilities. Then, a switching diagram was designed according to the relationship between the indoor air temperature and humidity and their setting ranges. When the two indoor environmental factors reach their upper or lower limits, IARX models are used to predict them over a specified horizon for each optional mode respectively. Mode switching is carried out based on prediction results. The switching control strategy was simulated based on a mechanistic model of the greenhouse microclimate. The results show that the facilities can be coordinated very well by the proposed control strategy and it is easy to implement. The control strategy is still applicative when more facilities or more indoor environmental factors need to be taken into account.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2017-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/3680</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2017.49.5.9</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 49 No. 5 (2017); 689-703</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2017.49.5</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/3680/3085</dc:relation>
</oai_dc:dc>