Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Disinfection Performance against Salmonella Typhi in Water by Radio Frequency Inductive Couple Plasma System

Journal of Engineering and Technological Sciences · Vol. 49 No. 6 (2017) · hlm. 737–749

DOI
10.5614/j.eng.technol.sci.2017.49.6.3
ISSN
2338-5502, 2337-5779
Terbit
2017-12-29
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

The disinfection performance of the radio frequency inductively coupled plasma (RFICP) system against Salmonella Typhi in water was examined using continuous flow experiments. The evaluation was based on disinfection efficiency, death rate constant, disinfection yield, and energy consumption. For all experiments the electromagnetic flux generated in the plasma reactor varied from 4 to 6 W/cm2. The disinfection efficiency and death rate constant of Salmonella Typhi decreased with the increase of the initial number of Salmonella Typhi bacteria. The disinfection yield increased from 784 to 1889 CFU/KWh and the energy consumption decreased from 0.28 to 0.07 KWh/L with the flowrate increasing from 5 to 20 mL/minute. The flowrate is an important parameter in predicting disinfection performance against pathogenic bacteria in water to design drinking water treatment plants.

Kata kunci

Jaringan kolaborasi para penulis

23 penulis · 51 tautan kepenulisan bersama · 24 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Andalas University
  • Gifu University
  • Universitas Bung Hatta
  • Universitas Borobudur
  • Sumatera Institute of Technology
  • Universitas Jambi
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Primas EmeraldiAndalas University6
Eka Putra WaldiAndalas University4
Darwison DarwisonAndalas University2
Toshiro YamadaGifu University2
Hongjie GuiGifu University2
Yongfen WeiGifu University2
YulastriAfiliasi tidak diketahui2
Dean CorioSumatera Institute of Technology2
Fu-Sheng LiAfiliasi tidak diketahui1
Syukri AriefAndalas University1
Ellyta SariUniversitas Bung Hatta1
Zulhadjri ZulhadjriAndalas University1
Matlal Fajri AlifAndalas University1
Maulana Yusup RosadiUniversitas Borobudur1
Hanalde AndreAndalas University1
Agus Rahmad TimorAndalas University1
Zulka HendriAndalas University1
Andrew Kurniawan VadreasAndalas University1
Syaifa MulyadiAndalas University1
Dasrinal TessalUniversitas Jambi1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Disinfection Performance against Salmonella Typhi in Water by Radio Frequency Inductive Couple Plasma System</dc:title>
	<dc:creator>Desmiarti, Reni</dc:creator>
	<dc:creator>Hazmi, Ariadi</dc:creator>
	<dc:creator>Li, Fusheng</dc:creator>
	<dc:subject xml:lang="en-US">disinfection</dc:subject>
	<dc:subject xml:lang="en-US">pathogenic bacteria</dc:subject>
	<dc:subject xml:lang="en-US">radio frequency inductively coupled plasma system</dc:subject>
	<dc:subject xml:lang="en-US">Salmonella Typhi</dc:subject>
	<dc:subject xml:lang="en-US">water treatment.</dc:subject>
	<dc:description xml:lang="en-US">The disinfection performance of the radio frequency inductively coupled plasma (RFICP) system against Salmonella Typhi in water was examined using continuous flow experiments. The evaluation was based on disinfection efficiency, death rate constant, disinfection yield, and energy consumption. For all experiments the electromagnetic flux generated in the plasma reactor varied from 4 to 6 W/cm2. The disinfection efficiency and death rate constant of Salmonella Typhi decreased with the increase of the initial number of Salmonella Typhi bacteria. The disinfection yield increased from 784 to 1889 CFU/KWh and the energy consumption decreased from 0.28 to 0.07 KWh/L with the flowrate increasing from 5 to 20 mL/minute. The flowrate is an important parameter in predicting disinfection performance against pathogenic bacteria in water to design drinking water treatment plants.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2017-12-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/4575</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2017.49.6.3</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 49 No. 6 (2017); 737-749</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2017.49.6</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/4575/3096</dc:relation>
</oai_dc:dc>