Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Comparative Evaluation of Medical Thermal Image Enhancement Techniques for Breast Cancer Detection

Journal of Engineering and Technological Sciences · Vol. 50 No. 1 (2018) · hlm. 40–52

DOI
10.5614/j.eng.technol.sci.2018.50.1.3
ISSN
2338-5502, 2337-5779
Terbit
2018-03-31
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

Thermography is a potential medical imaging modality due to its capability in providing additional physiological information. Medical thermal images obtained from infrared thermography systems incorporate valuable temperature properties and profiles, which could indicate underlying abnormalities. The quality of thermal images is often degraded due to noise, which affects the measurement processes in medical imaging. Contrast stretching and image filtering techniques are normally adopted in medical image enhancement processes. In this study, a comparative evaluation of contrast stretching and image filtering on individual channels of true color thermal images was conducted. Their individual performances were quantitatively measured using mean square error (MSE) and peak signal to noise ratio (PSNR). The results obtained showed that contrast stretching altered the temperature profile of the original image while image filtering appeared to enhance the original image with no changes in its profile. Further measurement of both MSE and PSNR showed that the Wiener filtering method outperformed other filters with an average MSE value of 0.0045 and PSNR value of 78.739 dB. Various segmentation methods applied to both filtered and contrast stretched images proved that the filtering method is preferable for in-depth analysis.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Malaysia
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Muhammad Haikal SatriaUniversity of Technology Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative Evaluation of Medical Thermal Image Enhancement Techniques for Breast Cancer Detection</dc:title>
	<dc:creator>Abdul Wahab, Asnida</dc:creator>
	<dc:creator>Mohamad Salim, Maheza Irna</dc:creator>
	<dc:creator>Yunus, Jasmy</dc:creator>
	<dc:creator>Ramlee, Muhammad Hanif</dc:creator>
	<dc:subject xml:lang="en-US">contrast stretching</dc:subject>
	<dc:subject xml:lang="en-US">filtering</dc:subject>
	<dc:subject xml:lang="en-US">image enhancement</dc:subject>
	<dc:subject xml:lang="en-US">medical thermal image</dc:subject>
	<dc:subject xml:lang="en-US">thermography technique.</dc:subject>
	<dc:description xml:lang="en-US">Thermography is a potential medical imaging modality due to its capability in providing additional physiological information. Medical thermal images obtained from infrared thermography systems incorporate valuable temperature properties and profiles, which could indicate underlying abnormalities. The quality of thermal images is often degraded due to noise, which affects the measurement processes in medical imaging. Contrast stretching and image filtering techniques are normally adopted in medical image enhancement processes. In this study, a comparative evaluation of contrast stretching and image filtering on individual channels of true color thermal images was conducted. Their individual performances were quantitatively measured using mean square error (MSE) and peak signal to noise ratio (PSNR). The results obtained showed that contrast stretching altered the temperature profile of the original image while image filtering appeared to enhance the original image with no changes in its profile. Further measurement of both MSE and PSNR showed that the Wiener filtering method outperformed other filters with an average MSE value of 0.0045 and PSNR value of 78.739 dB. Various segmentation methods applied to both filtered and contrast stretched images proved that the filtering method is preferable for in-depth analysis.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2018-03-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/5485</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2018.50.1.3</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 50 No. 1 (2018); 40-52</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/5485/3157</dc:relation>
</oai_dc:dc>