Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Theoretical Beam Hardening Correction for Industrial X-ray Computed Tomography

Journal of Engineering and Technological Sciences · Vol. 51 No. 6 (2019) · hlm. 869–880

DOI
10.5614/j.eng.technol.sci.2019.51.6.9
ISSN
2338-5502, 2337-5779
Terbit
2019-12-31
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

Beam hardening is a significant artifact that comes from the polychromatic nature of the X-ray source in computed tomography. It appears because the object tends to absorb more low-energy photons within the beam, which leads to a nonlinear relationship between attenuation and material thickness. As a result, the reconstructed image is spoiled. This work articulates an approach to promoting the correction of MeV X-ray beam hardening. In order to calculate the attenuation of the polychromatic beam, the following terms were evaluated: the energy spectra S(E) for sets of X-ray spectra with a maximum energy of 2, 4, 6 and 9 MeV were simulated using the Geant4 toolkit; the counting efficiency λ(E) was estimated based on the Lifton method; and the attenuation coefficient µ(E) was taken from the NIST database. The non-linear relationship between the attenuation and the thickness of iron was investigated. The beam hardening for each energy set was successfully corrected by polynomial fitting, transforming the polychromatic attenuation data into equivalent monochromatic data. The corrected attenuation was used to estimate the penetration capability of the X-ray source and produced a result that was consistent with what has been reported in the literature.

Kata kunci

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Harbin Engineering University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Theoretical Beam Hardening Correction for Industrial X-ray Computed Tomography</dc:title>
	<dc:creator>Ahmed, Osama Mhmood Hamed</dc:creator>
	<dc:creator>Song, YuShou</dc:creator>
	<dc:creator>Zhaoyang, Xie</dc:creator>
	<dc:subject xml:lang="en-US">beam hardening</dc:subject>
	<dc:subject xml:lang="en-US">computed tomography</dc:subject>
	<dc:subject xml:lang="en-US">X-ray attenuation</dc:subject>
	<dc:subject xml:lang="en-US">counting efficiency</dc:subject>
	<dc:subject xml:lang="en-US">polychromatic X-ray</dc:subject>
	<dc:subject xml:lang="en-US">monochromatic X-ray</dc:subject>
	<dc:subject xml:lang="en-US">polynomial fitting</dc:subject>
	<dc:description xml:lang="en-US">Beam hardening is a significant artifact that comes from the polychromatic nature of the X-ray source in computed tomography. It appears because the object tends to absorb more low-energy photons within the beam, which leads to a nonlinear relationship between attenuation and material thickness. As a result, the reconstructed image is spoiled. This work articulates an approach to promoting the correction of MeV X-ray beam hardening. In order to calculate the attenuation of the polychromatic beam, the following terms were evaluated: the energy spectra S(E) for sets of X-ray spectra with a maximum energy of 2, 4, 6 and 9 MeV were simulated using the Geant4 toolkit; the counting efficiency λ(E) was estimated based on the Lifton method; and the attenuation coefficient µ(E) was taken from the NIST database. The non-linear relationship between the attenuation and the thickness of iron was investigated. The beam hardening for each energy set was successfully corrected by polynomial fitting, transforming the polychromatic attenuation data into equivalent monochromatic data. The corrected attenuation was used to estimate the penetration capability of the X-ray source and produced a result that was consistent with what has been reported in the literature.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2019-12-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/11361</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2019.51.6.9</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 51 No. 6 (2019); 869-880</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2019.51.6</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/11361/pdf_45</dc:relation>
</oai_dc:dc>