Jurnal
SINTA 1
Study on the Influence of Toilet Siphon Pipe Shape on Flushing Performance
Journal of Engineering and Technological Sciences · Vol. 52 No. 6 (2020) · hlm. 779–797
ISSN 2338-5502, 2337-5779
Terbit 2020-11-30
Penerbit Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa eng
Abstrak
The goal of this work was to explore the influence of toilet siphon pipe shape on flushing performance. The flushing processes of a toilet under different shape parameters were simulated by using computational fluid dynamics (CFD) with a volume of fluid (VOF) multiphase model. The effects of siphon pipe shape on flushing performance were analyzed in detail. The interpretation of the simulation results was experimentally validated. The results reveal that a toilet may obtain good flushing performance under one single shape parameter when the climbing angle, the arc width, the arc height, the pipe diameter, the climbing width, and the climbing height are about 48°, 45 mm, 210 mm, 50 mm, 90 mm and 30 mm, respectively. With the increase of the siphon pipe diameter, the toilet flushing performance peaks in the range between 50 and 53 mm rather than continuing to improve. In order to reasonably evaluate the flushing effect of the toilet, all flow parameters on a characteristic cross section of the siphon pipe, including the average velocity, the average pressure and the average mass flow rate, should be comprehensively considered instead of one single parameter. The findings of this study provide a reference for the pipe shape design of toilets.
Jaringan kolaborasi para penulis
21 penulis ·
68 tautan kepenulisan bersama
· 30 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Huangshan University Fujian University of Technology Huaqiao University Nanjing University of Aeronautics and Astronautics National Technical University "Kharkiv Polytechnic Institute"
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Study on the Influence of Toilet Siphon Pipe Shape on Flushing Performance</dc:title>
<dc:creator>Ge, Xiaole</dc:creator>
<dc:creator>Wang, Hongfeng</dc:creator>
<dc:creator>Li, Zhanfu</dc:creator>
<dc:creator>Liu, Shengrong</dc:creator>
<dc:creator>Tong, Xin</dc:creator>
<dc:creator>Pu, Jiafei</dc:creator>
<dc:creator>Dong, Qi</dc:creator>
<dc:subject xml:lang="en-US">CFD</dc:subject>
<dc:subject xml:lang="en-US">flushing performance</dc:subject>
<dc:subject xml:lang="en-US">shape parameters</dc:subject>
<dc:subject xml:lang="en-US">siphon pipe</dc:subject>
<dc:subject xml:lang="en-US">toilet.</dc:subject>
<dc:description xml:lang="en-US">The goal of this work was to explore the influence of toilet siphon pipe shape on flushing performance. The flushing processes of a toilet under different shape parameters were simulated by using computational fluid dynamics (CFD) with a volume of fluid (VOF) multiphase model. The effects of siphon pipe shape on flushing performance were analyzed in detail. The interpretation of the simulation results was experimentally validated. The results reveal that a toilet may obtain good flushing performance under one single shape parameter when the climbing angle, the arc width, the arc height, the pipe diameter, the climbing width, and the climbing height are about 48°, 45 mm, 210 mm, 50 mm, 90 mm and 30 mm, respectively. With the increase of the siphon pipe diameter, the toilet flushing performance peaks in the range between 50 and 53 mm rather than continuing to improve. In order to reasonably evaluate the flushing effect of the toilet, all flow parameters on a characteristic cross section of the siphon pipe, including the average velocity, the average pressure and the average mass flow rate, should be comprehensively considered instead of one single parameter. The findings of this study provide a reference for the pipe shape design of toilets.</dc:description>
<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
<dc:date>2020-11-30</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/11676</dc:identifier>
<dc:identifier>10.5614/j.eng.technol.sci.2020.52.6.1</dc:identifier>
<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 52 No. 6 (2020); 779-797</dc:source>
<dc:source>2338-5502</dc:source>
<dc:source>2337-5779</dc:source>
<dc:source>10.5614/j.eng.technol.sci.2020.52.6</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/11676/5210</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2021 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ge, X., Wang, H., Li, Z., Liu, S., Tong, X., Pu, J., & Dong, Q. (2020). Study on the Influence of Toilet Siphon Pipe Shape on Flushing Performance. Journal of Engineering and Technological Sciences, 52(6), 779–797. https://doi.org/10.5614/j.eng.technol.sci.2020.52.6.1
Salin
IEEE
X. Ge, H. Wang, Z. Li, S. Liu, X. Tong, J. Pu, and Q. Dong, “Study on the Influence of Toilet Siphon Pipe Shape on Flushing Performance,” Journal of Engineering and Technological Sciences, vol. 52, no. 6, pp. 779–797, 2020, doi: 10.5614/j.eng.technol.sci.2020.52.6.1.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.