Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Comparison of Static Model, Adaptation Study, and CFD Simulation in Evaluating Thermal Comfort Based on Köppen Climate Classification System in Churches in Indonesia

Journal of Engineering and Technological Sciences · Vol. 53 No. 6 (2021)

DOI
10.5614/j.eng.technol.sci.2021.53.6.6
ISSN
2338-5502, 2337-5779
Terbit
2021-12-22
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

This research examined thermal comfort in church buildings in Indonesia by making a comparison between three different Indonesian climatic regions using three different research models. A static model, an adaptation study model and a CFD simulation were used to find the similarities and differences between the results generated from determining thermal comfort in church buildings in the three regions. The comparison revealed that church buildings had different PMV scores at each measuring point that were inversely proportional to the subjects’ response on thermal comfort inside the buildings, i.e. points adjoining with openings affect a low PMV score and a high perceived thermal sensation, and vice versa. The CFD simulation showed that changing the conditions of the openings affects air velocity and flow into the building, which influences the subjects’ thermal comfort response inside the churches.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Udayana University
  • Universitas Nusa Nipa Maumere
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ida Bagus Gde WirawibawaUdayana University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparison of Static Model, Adaptation Study, and CFD Simulation in Evaluating Thermal Comfort Based on Köppen Climate Classification System in Churches in Indonesia</dc:title>
	<dc:creator>Hildegardis, Cornelia</dc:creator>
	<dc:creator>Saraswati, Anak Agung Ayu Oka</dc:creator>
	<dc:creator>Putra, I Dewa Gede Agung Diasana</dc:creator>
	<dc:creator>Dewi, Ni Ketut Agusinta</dc:creator>
	<dc:subject xml:lang="en-US">computational fluid dynamics</dc:subject>
	<dc:subject xml:lang="en-US">church</dc:subject>
	<dc:subject xml:lang="en-US">thermal comfort</dc:subject>
	<dc:subject xml:lang="en-US">PMV</dc:subject>
	<dc:subject xml:lang="en-US">perception</dc:subject>
	<dc:subject xml:lang="en-US">Engineering</dc:subject>
	<dc:description xml:lang="en-US">This research examined thermal comfort in  church buildings in Indonesia by making a comparison between three different Indonesian climatic regions using three different research models. A static model, an adaptation study model and a CFD simulation were used to find the similarities and differences between the results generated from determining thermal comfort in church buildings in the three regions. The comparison revealed that church buildings had different PMV scores at each measuring point that were inversely proportional to the subjects’ response on thermal comfort inside the buildings, i.e. points adjoining with openings affect a low PMV score and a high perceived thermal sensation, and vice versa. The CFD simulation showed that changing the conditions of the openings affects air velocity and flow into the building, which influences the subjects’ thermal comfort response inside the churches.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2021-12-22</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/13825</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2021.53.6.6</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 53 No. 6 (2021); 210606</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2021.53.6</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/13825/5541</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>