Every building has certain electricity consumption patterns that depend on its usage. Building electricity budget planning requires a consumption forecast to determine the baseline electricity load and to support energy management decisions. In this study, an algorithm to model building electricity consumption was developed. The algorithm is based on the support vector regression (SVR) method. Data of electricity consumption from the past five years from a selected building object in ITB campus were used. The dataset unexpectedly exhibited a large number of anomalous points. Therefore, a tolerance limit of hourly average energy consumption was defined to obtain good quality training data. Various tolerance limits were investigated, that is 15% (Type 1), 30% (Type 2), and 0% (Type 0). The optimal model was selected based on the criteria of mean absolute percentage error (MAPE) < 20% and root mean square error (RMSE) < 10 kWh. Type 1 data was selected based on its performance compared to the other two. In a real implementation, the model yielded a MAPE value of 14.79% and an RMSE value of 7.48 kWh when predicting weekly electricity consumption. Therefore, the Type 1 data-based model could satisfactorily forecast building electricity consumption.

Kata kunci

Jaringan kolaborasi para penulis

30 penulis · 94 tautan kepenulisan bersama · 18 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Sumatera Institute of Technology
  • Indonesian Institute of Sciences
  • Telkom University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
F.X. Nugroho SoelamiBandung Institute of Technology5
Koko FriansaSumatera Institute of Technology4
M Daya ImannataBandung Institute of Technology4
Timothius Pratama TjahjaBandung Institute of Technology4
Reza Fauzi IskandarTelkom University4
Auditio MandhanyBandung Institute of Technology4
Rezky Mahesa NandaBandung Institute of Technology4
Yohannes S. M. SimamoraBandung Institute of Technology3
Harijono A. TjokronegoroBandung Institute of Technology3
Muhamad Riezar Satria ShebaBandung Institute of Technology3
Alief Widjoseno Damar PersadaBandung Institute of Technology3
Hanafi KusumayudhaBandung Institute of Technology3
Salsabila RegitaBandung Institute of Technology3
Mediya WasesaBandung Institute of Technology3
Irsan Soemantri BrodjonegoroBandung Institute of Technology2
Brian YuliartoBandung Institute of Technology2
Deddy KurniadiBandung Institute of Technology2
Fakhri Ihsan RamadhanBandung Institute of Technology1
Mochammad Agus AfriantoBandung Institute of Technology1
Radit RahmadhanBandung Institute of Technology1
Siti AnisahBandung Institute of Technology1
Rishal AsriSumatera Institute of Technology1
Monna RozanaIndonesian Institute of Sciences1
Upekkha LauBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Data Driven Building Electricity Consumption Model Using Support Vector Regression</dc:title>
	<dc:creator>Soelami, FX Nugroho</dc:creator>
	<dc:creator>Kertha Utama, Putu Handre</dc:creator>
	<dc:creator>Haq, Irsyad Nashirul</dc:creator>
	<dc:creator>Pradipta, Justin</dc:creator>
	<dc:creator>Leksono, Edi</dc:creator>
	<dc:creator>Wasesa, Meditya</dc:creator>
	<dc:subject xml:lang="en-US">building  electricity  consumption  prediction</dc:subject>
	<dc:subject xml:lang="en-US">consumption  patterns</dc:subject>
	<dc:subject xml:lang="en-US">data driven modeling</dc:subject>
	<dc:subject xml:lang="en-US">historical database</dc:subject>
	<dc:subject xml:lang="en-US">support vector regression</dc:subject>
	<dc:description xml:lang="en-US">Every building has certain electricity consumption patterns that depend on its usage. Building electricity budget planning requires a consumption forecast to determine the baseline electricity load and to support energy management decisions. In this study, an algorithm to model building electricity consumption was developed. The algorithm is based on the support vector regression (SVR) method. Data of electricity consumption from the past five years from a selected building object in ITB campus were used. The dataset unexpectedly exhibited a large number of anomalous points. Therefore, a tolerance limit of hourly average energy consumption was defined to obtain good quality training data. Various tolerance limits were investigated, that is 15% (Type 1), 30% (Type 2), and 0% (Type 0). The optimal model was selected based on the criteria of mean absolute percentage error (MAPE) &amp;lt; 20% and root mean square error (RMSE) &amp;lt; 10 kWh. Type 1 data was selected based on its performance compared to the other two. In a real implementation, the model yielded a MAPE value of 14.79% and an RMSE value of 7.48 kWh when predicting weekly electricity consumption. Therefore, the Type 1 data-based model could satisfactorily forecast building electricity consumption.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2021-07-12</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/14141</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2021.53.3.13</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 53 No. 3 (2021); 210313</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/10.5614/j.eng.technol.sci.2021.53.3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/14141/5303</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>