Jurnal
SINTA 1
Assessing Log Reduction Values of Conventional Water Treatment Plants with Microbially Highly Polluted Raw Water Sources
Journal of Engineering and Technological Sciences · Vol. 54 No. 1 (2022)
ISSN 2338-5502, 2337-5779
Terbit 2022-01-28
Penerbit Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa eng
Abstrak
Because of the global outlook of microbial pathogens contributed by river basins that are characterized by highly populated urbanized areas and other activities with poor wastewater management, it is imperative to assess the sufficiency of conventional water treatment plants with microbially highly polluted raw surface water sources in supplying pathogen-free drinking water. By using the log reduction value (LRV), the microbial safety of the drinking water supply from WTP Badaksinga, Bandung City, Indonesia, was assessed, from the raw water sources to the conventional water treatment units. E. coli, total coliform, and Clostridium perfringens (as a surrogate of the Cryptosporidium parvum protozoan) were selected as pathogens. It was found that with E. coli concentrations of > 20,000 MPN/100 ml, all the raw water sources should be categorized as not suitable for drinking water sources. The LRVs of conventional treatment units ranged from 0.67 to 1.4 for all pathogens. For the disinfection unit, the LRVs ranged from 3.0 to 3.71 for E. coli and total coliform, and 0 for Clostridium perfringens. Based on the results, the drinking water from WTP Badaksinga is safe from bacteria contamination but theoretically requires an additional barrier for protozoa safety. The assessment found that the LRVs of pre-sedimentation and combined flocculation-sedimentation units in conventional treatment systems need to be (re)assessed.
Jaringan kolaborasi para penulis
11 penulis ·
26 tautan kepenulisan bersama
· 15 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Bandung Institute of Technology Udayana University National Nuclear Energy Agency of Indonesia Radboud University Nijmegen Van Hall Larenstein University of Applied Sciences
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Assessing Log Reduction Values of Conventional Water Treatment Plants with Microbially Highly Polluted Raw Water Sources</dc:title>
<dc:creator>Sudradjat, Arief</dc:creator>
<dc:creator>Angga, Made Sandhyana </dc:creator>
<dc:creator>Barlian, Kevin</dc:creator>
<dc:creator>Nastiti, Anindrya</dc:creator>
<dc:subject xml:lang="en-US">conventional treatment</dc:subject>
<dc:subject xml:lang="en-US">drinking water</dc:subject>
<dc:subject xml:lang="en-US">LRV</dc:subject>
<dc:subject xml:lang="en-US">microbial safety</dc:subject>
<dc:subject xml:lang="en-US">raw water source</dc:subject>
<dc:subject xml:lang="en-US">Environmental Engineering</dc:subject>
<dc:description xml:lang="en-US">Because of the global outlook of microbial pathogens contributed by river basins that are characterized by highly populated urbanized areas and other activities with poor wastewater management, it is imperative to assess the sufficiency of conventional water treatment plants with microbially highly polluted raw surface water sources in supplying pathogen-free drinking water. By using the log reduction value (LRV), the microbial safety of the drinking water supply from WTP Badaksinga, Bandung City, Indonesia, was assessed, from the raw water sources to the conventional water treatment units. E. coli, total coliform, and Clostridium perfringens (as a surrogate of the Cryptosporidium parvum protozoan) were selected as pathogens. It was found that with E. coli concentrations of &gt; 20,000 MPN/100 ml, all the raw water sources should be categorized as not suitable for drinking water sources. The LRVs of conventional treatment units ranged from 0.67 to 1.4 for all pathogens. For the disinfection unit, the LRVs ranged from 3.0 to 3.71 for E. coli and total coliform, and 0 for Clostridium perfringens. Based on the results, the drinking water from WTP Badaksinga is safe from bacteria contamination but theoretically requires an additional barrier for protozoa safety. The assessment found that the LRVs of pre-sedimentation and combined flocculation-sedimentation units in conventional treatment systems need to be (re)assessed.</dc:description>
<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
<dc:date>2022-01-28</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/15939</dc:identifier>
<dc:identifier>10.5614/j.eng.technol.sci.2022.54.1.1</dc:identifier>
<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 54 No. 1 (2022); 220101</dc:source>
<dc:source>2338-5502</dc:source>
<dc:source>2337-5779</dc:source>
<dc:source>10.5614/j.eng.technol.sci.2022.54.1</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/15939/5626</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Sudradjat, A., Angga, M. S., Barlian, K., & Nastiti, A. (2022). Assessing Log Reduction Values of Conventional Water Treatment Plants with Microbially Highly Polluted Raw Water Sources. Journal of Engineering and Technological Sciences, 54(1). https://doi.org/10.5614/j.eng.technol.sci.2022.54.1.1
Salin
IEEE
A. Sudradjat, M. S. Angga, K. Barlian, and A. Nastiti, “Assessing Log Reduction Values of Conventional Water Treatment Plants with Microbially Highly Polluted Raw Water Sources,” Journal of Engineering and Technological Sciences, vol. 54, no. 1, 2022, doi: 10.5614/j.eng.technol.sci.2022.54.1.1.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.