Design of Split-Hopkinson Pressure Bar Specimen Fixture to Accommodate Punch and Double-Notch Shear Testing
Journal of Engineering and Technological Sciences · Vol. 54 No. 4 (2022)
ISSN 2338-5502, 2337-5779
Terbit 2022-07-18
Penerbit Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa eng
Abstrak
This study focused on the design of a specimen fixture which can be installed on the end of a conventional transmission bar so that shear testing (punch and double-notch) can be conducted with any conventional split-Hopkinson apparatus. The research was conducted by using the finite element method in Abaqus/CAE with 6061-T651 Aluminum as the specimen material. The research successfully determined the effect of the fixture’s geometry and dimensions on the split-Hopkinson shear bar testing results. The optimum double-notch fixture provides great accuracy, having only a shear stress value difference of 1.49% with the original setup, while attaining force equilibrium after only 70 μs. The punch fixture, however, could only reach force equilibrium after 100 μs, thus providing too few observable data. Future work on the punch fixture is needed.
Jaringan kolaborasi para penulis
7 penulis ·
13 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Bandung Institute of Technology
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Design of Split-Hopkinson Pressure Bar Specimen Fixture to Accommodate Punch and Double-Notch Shear Testing </dc:title>
<dc:creator>Dipajaya, Arya</dc:creator>
<dc:creator>Ahmad, Kemal I.</dc:creator>
<dc:creator>Kariem, Muhammad A.</dc:creator>
<dc:subject xml:lang="en-US">double-notch</dc:subject>
<dc:subject xml:lang="en-US">fixture</dc:subject>
<dc:subject xml:lang="en-US">impact</dc:subject>
<dc:subject xml:lang="en-US">property</dc:subject>
<dc:subject xml:lang="en-US">punch</dc:subject>
<dc:subject xml:lang="en-US">shear</dc:subject>
<dc:subject xml:lang="en-US">Split-Hopkinson bar</dc:subject>
<dc:subject xml:lang="en-US">Mechanical Engineering</dc:subject>
<dc:subject xml:lang="en-US">Material Engineering</dc:subject>
<dc:description xml:lang="en-US">This study focused on the design of a specimen fixture which can be installed on the end of a conventional transmission bar so that shear testing (punch and double-notch) can be conducted with any conventional split-Hopkinson apparatus. The research was conducted by using the finite element method in Abaqus/CAE with 6061-T651 Aluminum as the specimen material. The research successfully determined the effect of the fixture’s geometry and dimensions on the split-Hopkinson shear bar testing results. The optimum double-notch fixture provides great accuracy, having only a shear stress value difference of 1.49% with the original setup, while attaining force equilibrium after only 70 μs. The punch fixture, however, could only reach force equilibrium after 100 μs, thus providing too few observable data. Future work on the punch fixture is needed.</dc:description>
<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
<dc:date>2022-07-18</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/16405</dc:identifier>
<dc:identifier>10.5614/j.eng.technol.sci.2022.54.4.8</dc:identifier>
<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 54 No. 4 (2022); 220408</dc:source>
<dc:source>2338-5502</dc:source>
<dc:source>2337-5779</dc:source>
<dc:source>10.5614/j.eng.technol.sci.2022.54.4</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/16405/5860</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2022 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Dipajaya, A., Ahmad, K. I., & Kariem, M. A. (2022). Design of Split-Hopkinson Pressure Bar Specimen Fixture to Accommodate Punch and Double-Notch Shear Testing. Journal of Engineering and Technological Sciences, 54(4). https://doi.org/10.5614/j.eng.technol.sci.2022.54.4.8
Salin
IEEE
A. Dipajaya, K. I. Ahmad, and M. A. Kariem, “Design of Split-Hopkinson Pressure Bar Specimen Fixture to Accommodate Punch and Double-Notch Shear Testing,” Journal of Engineering and Technological Sciences, vol. 54, no. 4, 2022, doi: 10.5614/j.eng.technol.sci.2022.54.4.8.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.