Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Design of Split-Hopkinson Pressure Bar Specimen Fixture to Accommodate Punch and Double-Notch Shear Testing

Journal of Engineering and Technological Sciences · Vol. 54 No. 4 (2022)

DOI
10.5614/j.eng.technol.sci.2022.54.4.8
ISSN
2338-5502, 2337-5779
Terbit
2022-07-18
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

This study focused on the design of a specimen fixture which can be installed on the end of a conventional transmission bar so that shear testing (punch and double-notch) can be conducted with any conventional split-Hopkinson apparatus. The research was conducted by using the finite element method in Abaqus/CAE with 6061-T651 Aluminum as the specimen material. The research successfully determined the effect of the fixture’s geometry and dimensions on the split-Hopkinson shear bar testing results. The optimum double-notch fixture provides great accuracy, having only a shear stress value difference of 1.49% with the original setup, while attaining force equilibrium after only 70 μs. The punch fixture, however, could only reach force equilibrium after 100 μs, thus providing too few observable data. Future work on the punch fixture is needed.

Kata kunci

Jaringan kolaborasi para penulis

7 penulis · 13 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bagus BudiwantoroBandung Institute of Technology1
Iffah FaizahBandung Institute of Technology1
Dini A. PrabowoBandung Institute of Technology1
Burhan FebrinawartaBandung Institute of Technology1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of Split-Hopkinson Pressure Bar Specimen Fixture to Accommodate Punch and Double-Notch Shear Testing </dc:title>
	<dc:creator>Dipajaya, Arya</dc:creator>
	<dc:creator>Ahmad, Kemal I.</dc:creator>
	<dc:creator>Kariem, Muhammad A.</dc:creator>
	<dc:subject xml:lang="en-US">double-notch</dc:subject>
	<dc:subject xml:lang="en-US">fixture</dc:subject>
	<dc:subject xml:lang="en-US">impact</dc:subject>
	<dc:subject xml:lang="en-US">property</dc:subject>
	<dc:subject xml:lang="en-US">punch</dc:subject>
	<dc:subject xml:lang="en-US">shear</dc:subject>
	<dc:subject xml:lang="en-US">Split-Hopkinson bar</dc:subject>
	<dc:subject xml:lang="en-US">Mechanical Engineering</dc:subject>
	<dc:subject xml:lang="en-US">Material Engineering</dc:subject>
	<dc:description xml:lang="en-US">This study focused on the design of a specimen fixture which can be installed on the end of a conventional transmission bar so that shear testing (punch and double-notch) can be conducted with any conventional split-Hopkinson apparatus. The research was conducted by using the finite element method in Abaqus/CAE with 6061-T651 Aluminum as the specimen material. The research successfully determined the effect of the fixture’s geometry and dimensions on the split-Hopkinson shear bar testing results. The optimum double-notch fixture provides great accuracy, having only a shear stress value difference of 1.49% with the original setup, while attaining force equilibrium after only 70 μs. The punch fixture, however, could only reach force equilibrium after 100 μs, thus providing too few observable data. Future work on the punch fixture is needed.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2022-07-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/16405</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2022.54.4.8</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 54 No. 4 (2022); 220408</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2022.54.4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/16405/5860</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>