Due to their efficiency and adaptability, automated applications are consistently gaining popularity around the world. Robotics and their applications as used in a variety of commonplace industries, such as medical applications, require a high level of precision and accuracy. This can be achieved by utilizing automated applications. In this work, the development and design of a regulated injection pump is detailed. The developed prototype is a type of robot that can be utilized in hospitals and other medical facilities. The proposed design is used to pump specific liquid volumes as specified by the user. During liquid pumping, both the fluid’s volume and velocity can be manipulated. Implementation of the proposed system required the development of a complete mechanical system and a controller. The proposed system was implemented successfully, and its operation was deemed satisfactory. According to the results, the accuracy of the system was also satisfactory. Using a flow sensor, the reference value and the measured value acquired from the designed device were compared. Compared to similar devices, the proposed system demonstrated exceptional precision, with an average error rate of less than 1.5%. The proposed model has the advantages of using a commercially available injection syringe and being significantly less expensive than similar devices on the market.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 60 tautan kepenulisan bersama · 31 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Palestine Technical University - Kadoorie
  • Al-Balqa Applied University
  • University of Business and Technology
  • A'Sharqiyah University
  • Ajloun National University
  • Al-Hussein Bin Talal University
  • University of Missouri
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Anees Abu SneinehPalestine Technical University - Kadoorie6
Basim A. AlsayidPalestine Technical University - Kadoorie3
Mahmoud A. M. AlbreemA'Sharqiyah University2
Mutasem Sh. AlkhasawnehAjloun National University2
Anwar Al–MoflehAl-Balqa Applied University2
Amir Abu Al-AishAl-Hussein Bin Talal University2
Mohamed ElnaggarAfiliasi tidak diketahui2
Mai AbuhelwaUniversity of Missouri2
Ghazi QaryoutiAfiliasi tidak diketahui1
Anwar AlmoflehAfiliasi tidak diketahui1
Abdel Rahman SalbadAl-Balqa Applied University1
Sohaib A. TamimiAl-Balqa Applied University1
Qazem M. JaberAl-Balqa Applied University1
Yazeed AlawnehPalestine Technical University - Kadoorie1
Anees Abu SneinehAfiliasi tidak diketahui1
Arafat A. A. ShabanehAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Development of Smart and Portable Controllable Syringe Pump System for Medical Applications</dc:title>
	<dc:creator>Salah, Wael A.</dc:creator>
	<dc:creator>Zneid, Basem Abu</dc:creator>
	<dc:creator>Abu_Al_Aish, Amir</dc:creator>
	<dc:creator>Nofal, Mays</dc:creator>
	<dc:subject xml:lang="en-US">controllable</dc:subject>
	<dc:subject xml:lang="en-US">high precision</dc:subject>
	<dc:subject xml:lang="en-US">medical</dc:subject>
	<dc:subject xml:lang="en-US">microcontroller</dc:subject>
	<dc:subject xml:lang="en-US">portable</dc:subject>
	<dc:subject xml:lang="en-US">sensor</dc:subject>
	<dc:subject xml:lang="en-US">smart</dc:subject>
	<dc:subject xml:lang="en-US">syringe pump</dc:subject>
	<dc:subject xml:lang="en-US">Electronics</dc:subject>
	<dc:subject xml:lang="en-US">Electrical</dc:subject>
	<dc:subject xml:lang="en-US">Medical Applications</dc:subject>
	<dc:description xml:lang="en-US">Due to their efficiency and adaptability, automated applications are consistently gaining popularity around the world. Robotics and their applications as used in a variety of commonplace industries, such as medical applications, require a high level of precision and accuracy. This can be achieved by utilizing automated applications. In this work, the development and design of a regulated injection pump is detailed. The developed prototype is a type of robot that can be utilized in hospitals and other medical facilities. The proposed design is used to pump specific liquid volumes as specified by the user. During liquid pumping, both the fluid’s volume and velocity can be manipulated. Implementation of the proposed system required the development of a complete mechanical system and a controller. The proposed system was implemented successfully, and its operation was deemed satisfactory. According to the results, the accuracy of the system was also satisfactory. Using a flow sensor, the reference value and the measured value acquired from the designed device were compared. Compared to similar devices, the proposed system demonstrated exceptional precision, with an average error rate of less than 1.5%. The proposed model has the advantages of using a commercially available injection syringe and being significantly less expensive than similar devices on the market.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2023-08-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/19349</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2023.55.3.7</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 55 No. 3 (2023); 300-312</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2023.55.3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/19349/6306</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>