Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Design and Characterization of Ultrasonic Langevin Transducer 20 kHz Using a Stepped Horn Front-Mass

Journal of Engineering and Technological Sciences · Vol. 55 No. 4 (2023) · hlm. 357–372

DOI
10.5614/j.eng.technol.sci.2023.55.4.1
ISSN
2338-5502, 2337-5779
Terbit
2023-10-26
Penerbit
Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa
eng

Abstrak

Ultrasonication is a method that is widely used in various fields. One of its applications is to accelerate the process of homogenization, emulsification, and extraction. In the ultrasonicator system, the transducer is an extremely important device. The resonant frequency, longitudinal vibration amplitude, and electromechanical coupling are the targets in designing an ultrasonic transducer. In this investigation, the main contribution was the development of a simple and effective method for mechanically tuning the resonant frequency of the transducer by adding mass to the front end of the mass or stepped horn. This study also aimed to obtain optimal results by examining the effects of geometric dimensions, bolt prestress, stress distribution, resonant frequency, amplitude, and electrical impedance. The ultrasonic transducer model was designed with a resonant frequency of 20 kHz and simulated using the finite element analysis. The steps involved included calculating the dimensions and geometric structure of the transducer, modeling using the finite-element method, and experimental validation. The simulation results and measurements showed that the series resonant frequency, electrical impedance, and effective electromechanical coupling of the Model-4 transducer 16∙13 mm radiator configuration were 20.15 kHz, 100 Ω, and 0.2229 from the simulation results, and 20.17 kHz, 24.91 Ω, and 0.2033 from the measurement results. A percentage difference, or relative error, of 0.1% was obtained between the simulation and the experimental results for this Model-4 with bolt prestressing at 15 kN.

Kata kunci

Jaringan kolaborasi para penulis

22 penulis · 80 tautan kepenulisan bersama · 44 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Indonesia University of Education
  • National University of Malaysia
  • National Research and Innovation Agency
  • Politeknik Negeri Bandung
  • State University of Jakarta
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Endang JuliastutiBandung Institute of Technology2
Irwan SetiawanPoliteknik Negeri Bandung2
Brian YuliartoBandung Institute of Technology1
Irsyad Nashirul HaqBandung Institute of Technology1
F.X. Nugroho SoelamiBandung Institute of Technology1
Edi LeksonoBandung Institute of Technology1
S. SuprijantoBandung Institute of Technology1
Hesty SusantiBandung Institute of Technology1
Vebi NadhiraBandung Institute of Technology1
Ida HamidahIndonesia University of Education1
Lilik HasanahIndonesia University of Education1
Roer Eka PawinantoIndonesia University of Education1
Ahmad AminudinIndonesia University of Education1
Widyaningrum IndrasariState University of Jakarta1
Chandra WulandariBandung Institute of Technology1
Budi MulyantiIndonesia University of Education1
Jumril YunasNational University of Malaysia1
Harbi Setyo NugrohoIndonesia University of Education1
Ahmad Rifqi Md ZainNational University of Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design and Characterization of Ultrasonic Langevin Transducer 20 kHz Using a Stepped Horn Front-Mass</dc:title>
	<dc:creator>Khairiyah, Aisyah Nurul</dc:creator>
	<dc:creator>Sugandi, Gandi</dc:creator>
	<dc:creator>Kurniadi, Deddy</dc:creator>
	<dc:subject xml:lang="en-US">bolt-clamped langevin transducer</dc:subject>
	<dc:subject xml:lang="en-US">effective electromechanical coupling coefficient</dc:subject>
	<dc:subject xml:lang="en-US">finite  element analysis</dc:subject>
	<dc:subject xml:lang="en-US">resonance characteristics</dc:subject>
	<dc:subject xml:lang="en-US">ultrasonication</dc:subject>
	<dc:description xml:lang="en-US">Ultrasonication is a method that is widely used in various fields. One of its applications is to accelerate the process of homogenization, emulsification, and extraction. In the ultrasonicator system, the transducer is an extremely important device. The resonant frequency, longitudinal vibration amplitude, and electromechanical coupling are the targets in designing an ultrasonic transducer. In this investigation, the main contribution was the development of a simple and effective method for mechanically tuning the resonant frequency of the transducer by adding mass to the front end of the mass or stepped horn. This study also aimed to obtain optimal results by examining the effects of geometric dimensions, bolt prestress, stress distribution, resonant frequency, amplitude, and electrical impedance. The ultrasonic transducer model was designed with a resonant frequency of 20 kHz and simulated using the finite element analysis. The steps involved included calculating the dimensions and geometric structure of the transducer, modeling using the finite-element method, and experimental validation. The simulation results and measurements showed that the series resonant frequency, electrical impedance, and effective electromechanical coupling of the Model-4 transducer 16∙13 mm radiator configuration were 20.15 kHz, 100 Ω, and 0.2229 from the simulation results, and 20.17 kHz, 24.91 Ω, and 0.2033 from the measurement results. A percentage difference, or relative error, of 0.1% was obtained between the simulation and the experimental results for this Model-4 with bolt prestressing at 15 kN.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
	<dc:date>2023-10-26</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/19680</dc:identifier>
	<dc:identifier>10.5614/j.eng.technol.sci.2023.55.4.1</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 55 No. 4 (2023); 357-372</dc:source>
	<dc:source>2338-5502</dc:source>
	<dc:source>2337-5779</dc:source>
	<dc:source>10.5614/j.eng.technol.sci.2023.55.4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/19680/6365</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>