Jurnal
SINTA 1
Thermodynamic Study on Decarbonization of Combined Cycle Power Plant
Journal of Engineering and Technological Sciences · Vol. 55 No. 5 (2023) · hlm. 613–626
ISSN 2338-5502, 2337-5779
Terbit 2023-12-29
Penerbit Directorate for Research and Community Services, Institut Teknologi Bandung
Bahasa eng
Abstrak
Integrating hydrogen firing and a carbon capture plant (CCP) into a natural gas combined cycle (NGCC) power plant is a promising strategy for reducing CO2. In this study, process simulation in Aspen PLUS of hydrogen co-firing in a 40 MW turbine gas combined cycle power plant was done at an identical gas turbine inlet temperature from 0%.cal to 30%.cal. The evaluated cases were hydrogen co-firing with CCP (H2 Co-firing + CCP) and hydrogen co-firing without CCP (H2 Co-firing). The results showed a 6% CO2 emission reduction per 5% increase in hydrogen, albeit with increased NOx emissions. H2 Co-firing experienced a decrease in net power with rising hydrogen co-firing, while H2 Co-firing + CCP saw an increase but remained below Case 2 due to the energy penalty from the carbon capture plant. The capital cost of H2 Co-firing + CCP exceeds that of H2 Co-firing due to CCP usage, impacting gross revenue. The sensitivity analysis indicated that the cost of hydrogen has higher sensitivity compared to the cost of CCP. Lowering hydrogen prices is recommended to effectively reduce CO2 emissions in NGCC.
Jaringan kolaborasi para penulis
7 penulis ·
17 tautan kepenulisan bersama
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Bandung Institute of Technology Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jets/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Thermodynamic Study on Decarbonization of Combined Cycle Power Plant</dc:title>
<dc:creator>Ahmad, Azaria Haykal</dc:creator>
<dc:creator>Darmanto, Prihadi Setyo</dc:creator>
<dc:creator>Juangsa, Firman Bagja</dc:creator>
<dc:subject xml:lang="en-US">carbon capture</dc:subject>
<dc:subject xml:lang="en-US">co-firing</dc:subject>
<dc:subject xml:lang="en-US">combined cycle</dc:subject>
<dc:subject xml:lang="en-US">hydrogen</dc:subject>
<dc:subject xml:lang="en-US">natural gas</dc:subject>
<dc:subject xml:lang="en-US">Non Carbon Power Generation</dc:subject>
<dc:description xml:lang="en-US">Integrating hydrogen firing and a carbon capture plant (CCP) into a natural gas combined cycle (NGCC) power plant is a promising strategy for reducing CO2. In this study, process simulation in Aspen PLUS of hydrogen co-firing in a 40 MW turbine gas combined cycle power plant was done at an identical gas turbine inlet temperature from 0%.cal to 30%.cal. The evaluated cases were hydrogen co-firing with CCP (H2 Co-firing + CCP) and hydrogen co-firing without CCP (H2 Co-firing). The results showed a 6% CO2 emission reduction per 5% increase in hydrogen, albeit with increased NOx emissions. H2 Co-firing experienced a decrease in net power with rising hydrogen co-firing, while H2 Co-firing + CCP saw an increase but remained below Case 2 due to the energy penalty from the carbon capture plant. The capital cost of H2 Co-firing + CCP exceeds that of H2 Co-firing due to CCP usage, impacting gross revenue. The sensitivity analysis indicated that the cost of hydrogen has higher sensitivity compared to the cost of CCP. Lowering hydrogen prices is recommended to effectively reduce CO2 emissions in NGCC.</dc:description>
<dc:publisher xml:lang="en-US">Directorate for Research and Community Services, Institut Teknologi Bandung</dc:publisher>
<dc:date>2023-12-29</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journals.itb.ac.id/index.php/jets/article/view/21148</dc:identifier>
<dc:identifier>10.5614/j.eng.technol.sci.2023.55.5.10</dc:identifier>
<dc:source xml:lang="en-US">Journal of Engineering and Technological Sciences; Vol. 55 No. 5 (2023); 613-626</dc:source>
<dc:source>2338-5502</dc:source>
<dc:source>2337-5779</dc:source>
<dc:source>10.5614/j.eng.technol.sci.2023.55.5</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journals.itb.ac.id/index.php/jets/article/view/21148/6457</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2023 Journal of Engineering and Technological Sciences</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Ahmad, A. H., Darmanto, P. S., & Juangsa, F. B. (2023). Thermodynamic Study on Decarbonization of Combined Cycle Power Plant. Journal of Engineering and Technological Sciences, 55(5), 613–626. https://doi.org/10.5614/j.eng.technol.sci.2023.55.5.10
Salin
IEEE
A. H. Ahmad, P. S. Darmanto, and F. B. Juangsa, “Thermodynamic Study on Decarbonization of Combined Cycle Power Plant,” Journal of Engineering and Technological Sciences, vol. 55, no. 5, pp. 613–626, 2023, doi: 10.5614/j.eng.technol.sci.2023.55.5.10.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.