Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Comparative Analysis of Mosque Acoustics Quality in Tropical and Non-Tropical Climates: A Literature Review

Journal of Islamic Architecture · Vol. 9 No. 1 (2026) · hlm. 392–411

DOI
10.18860/jia.v9i1.29920
ISSN
2356-4644, 2086-2636
Terbit
2026-06-29
Penerbit
Department of Architecture, Faculty of Science and Technology, UIN Maliki Malang
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

This study investigates the comparative acoustic performance of tropical and non-tropical mosques, focusing on key parameters including Reverberation Time (RT), Clarity (C₈₀), Definition (D₅₀), and Speech Transmission Index (STI). Data were collected from multiple case studies, including tropical and non-tropical mosques, to evaluate their suitability for speech-related religious activities. A meta-analysis was conducted using acoustic datasets compiled from 20 mosques in the existing literature. Ordinary Least Squares (OLS) multiple linear regression models were constructed for each acoustic parameter to isolate the independent and combined predictive power of the structural variables. The results reveal that tropical mosques generally exhibit lower reverberation times and smaller deviations from recommended values, indicating more controlled acoustic environments. In contrast, non-tropical mosques tend to have higher RT values, often exceeding optimal limits due to large enclosed volumes and reflective materials. In terms of clarity (C₈₀) and definition (D₅₀), tropical mosques more frequently achieve values within or near recommended ranges, suggesting a better balance between early and late sound energy and improved speech intelligibility. Non-tropical mosques, however, exhibit greater variability, with several cases showing either excessive reverberation. The STI analysis further demonstrates that tropical mosques have the potential to achieve superior speech intelligibility. Non-tropical mosques generally fall within moderate levels of intelligibility. These differences are primarily influenced by architectural typology, spatial configuration, building volume, material characteristics, and the presence of electroacoustic systems. Tropical mosques, characterized by semi-open layouts and climate-responsive design strategies, inherently facilitate better sound dissipation and acoustic balance. This study concludes that while tropical mosque architecture tends to provide more favorable acoustic conditions, achieving optimal performance requires a holistic integration of architectural design, material selection, and acoustic treatment, regardless of climatic context.

Kata kunci

Jaringan kolaborasi para penulis

26 penulis · 53 tautan kepenulisan bersama · 27 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Universitas Islam Negeri Maulana Malik Ibrahim
  • University of Pembangunan Nasional Veteran Jawa Timur
  • Universiti Putra Malaysia
  • Tun Hussein Onn University of Malaysia
  • Diponegoro University
  • International Islamic University Malaysia
  • Organisasi lain
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Adinda AmaraInstitut Teknologi Sepuluh Nopember2
Audrey Tara DianagriInstitut Teknologi Sepuluh Nopember2
Sukjin JungPusan National University2
Jalaluddin MubarokDiponegoro University1
Elok MutiaraUniversitas Islam Negeri Maulana Malik Ibrahim1
Hanita YusofTun Hussein Onn University of Malaysia1
Azmal SabilTun Hussein Onn University of Malaysia1
Sumarni Binti IsmailUniversiti Putra Malaysia1
Nayeem AsifInternational Islamic University Malaysia1
Mohammad Ikram Mat SobriUniversiti Putra Malaysia1
Ansfiksia Eka Poetra YudhaUniversitas Islam Negeri Maulana Malik Ibrahim1
Pudji Pratitis WismantaraUniversitas Islam Negeri Maulana Malik Ibrahim1
Nur RozanUniversitas Islam Negeri Maulana Malik Ibrahim1
Dhany ArifiantoInstitut Teknologi Sepuluh Nopember1
Thomas Ari KristiantoInstitut Teknologi Sepuluh Nopember1
I Gusti Ngurah AntaryamaInstitut Teknologi Sepuluh Nopember1
Collinthia ErwindiInstitut Teknologi Sepuluh Nopember1
Wendy SunaryaUniversity of Pembangunan Nasional Veteran Jawa Timur1
Rizka Tiara MaharaniUniversity of Pembangunan Nasional Veteran Jawa Timur1
Sri Nastiti N. EkasiwiInstitut Teknologi Sepuluh Nopember1
Yusvika Ratri HarmunisaUniversity of Pembangunan Nasional Veteran Jawa Timur1
Dewi SeptantiInstitut Teknologi Sepuluh Nopember1
Nurma Fathia AlisyahInstitut Teknologi Sepuluh Nopember1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://ejournal.uin-malang.ac.id/index.php/JIA/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparative Analysis of Mosque Acoustics Quality in Tropical and Non-Tropical Climates: A Literature Review</dc:title>
	<dc:creator>Setiyowati, Ernaning</dc:creator>
	<dc:creator>Ekasiwi, Sri Nastiti Nugrahani</dc:creator>
	<dc:creator>Samodra, FX Teddy Badai</dc:creator>
	<dc:subject xml:lang="en-US">Architectural acoustic; Tropical mosque; Comparative study; Acoustics; Mosque design; Climatic architecture; Islamic architecture</dc:subject>
	<dc:description xml:lang="en-US">This study investigates the comparative acoustic performance of tropical and non-tropical mosques, focusing on key parameters including Reverberation Time (RT), Clarity (C₈₀), Definition (D₅₀), and Speech Transmission Index (STI). Data were collected from multiple case studies, including tropical and non-tropical mosques, to evaluate their suitability for speech-related religious activities. A meta-analysis was conducted using acoustic datasets compiled from 20 mosques in the existing literature. Ordinary Least Squares (OLS) multiple linear regression models were constructed for each acoustic parameter to isolate the independent and combined predictive power of the structural variables. The results reveal that tropical mosques generally exhibit lower reverberation times and smaller deviations from recommended values, indicating more controlled acoustic environments. In contrast, non-tropical mosques tend to have higher RT values, often exceeding optimal limits due to large enclosed volumes and reflective materials. In terms of clarity (C₈₀) and definition (D₅₀), tropical mosques more frequently achieve values within or near recommended ranges, suggesting a better balance between early and late sound energy and improved speech intelligibility. Non-tropical mosques, however, exhibit greater variability, with several cases showing either excessive reverberation. The STI analysis further demonstrates that tropical mosques have the potential to achieve superior speech intelligibility. Non-tropical mosques generally fall within moderate levels of intelligibility. These differences are primarily influenced by architectural typology, spatial configuration, building volume, material characteristics, and the presence of electroacoustic systems. Tropical mosques, characterized by semi-open layouts and climate-responsive design strategies, inherently facilitate better sound dissipation and acoustic balance. This study concludes that while tropical mosque architecture tends to provide more favorable acoustic conditions, achieving optimal performance requires a holistic integration of architectural design, material selection, and acoustic treatment, regardless of climatic context.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Architecture, Faculty of Science and Technology, UIN Maliki Malang</dc:publisher>
	<dc:contributor xml:lang="en-US"></dc:contributor>
	<dc:date>2026-06-29</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>http://ejournal.uin-malang.ac.id/index.php/JIA/article/view/29920</dc:identifier>
	<dc:identifier>10.18860/jia.v9i1.29920</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Islamic Architecture; Vol 9, No 1 (2026): Journal of Islamic Architecture; 392-411</dc:source>
	<dc:source>2356-4644</dc:source>
	<dc:source>2086-2636</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>http://ejournal.uin-malang.ac.id/index.php/JIA/article/view/29920/pdf</dc:relation>
	<dc:relation>http://ejournal.uin-malang.ac.id/index.php/JIA/article/downloadSuppFile/29920/11791</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Ernaning Setiyowati, Sri Nastiti N. Ekasiwi, FX Teddy Badai Samodra</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>