Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Beam Positions Optimization to Achieve Improved CT Images with Limited Data

Journal of Mathematical and Fundamental Sciences · Vol. 38 No. 2 (2013) · hlm. 133–147

DOI
10.5614/itbj.sci.2006.38.2.4
ISSN
2338-5510, 2337-5760
Terbit
2013-12-31
Penerbit
Directorate for Research and Innovation (DRI) ITB
Bahasa
eng

Abstrak

In radiotherapy planning, margins are used to account for the uncertainties due to internal organ and patient motion as well as set-up error. Improvement in radiotherapy treatments may be achieved by reducing the set-up uncertainty and thus treatment margins allowing a higher dose to be delivered to the target volume. It is important to be able to verify the success of the treatment by determining the position of patient and the dose deposited in the patient at each fraction. One possibility for achieving this would be to collect limited information while the patient is on the treatment couch. The aim of this study is to develop a method for determining intelligent angles to use to reconstruct an image for dose verification.A method optimizing the angles based on an objective function is required. The methods developed here are based on image correlation and projection correlation that have been investigated previously. Two optimization methods, deterministic and stochastic (simulated annealing), were also assessed. The effectiveness and practicality of each of these combinations were compared.

Jaringan kolaborasi para penulis

5 penulis · 10 tautan kepenulisan bersama · 7 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Diponegoro University
  • California State University, Channel Islands
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Choirul AnamDiponegoro University1
Freddy HaryantoBandung Institute of Technology1
Idam ArifBandung Institute of Technology1
Geoff DoughertyCalifornia State University, Channel Islands1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jmfs/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Beam Positions Optimization to Achieve Improved CT Images with Limited Data</dc:title>
	<dc:creator>Widita, Rena</dc:creator>
	<dc:description xml:lang="en-US"> In radiotherapy planning, margins are used to account for the uncertainties due to internal organ and patient motion as well as set-up error. Improvement in radiotherapy treatments may be achieved by reducing the set-up uncertainty and thus treatment margins allowing a higher dose to be delivered to the target volume. It is important to be able to verify the success of the treatment by determining the position of patient and the dose deposited in the patient at each fraction. One possibility for achieving this would be to collect limited information while the patient is on the treatment couch. The aim of this study is to develop a method for determining intelligent angles to use to reconstruct an image for dose verification.A method optimizing the angles based on an objective function is required. The methods developed here are based on image correlation and projection correlation that have been investigated previously. Two optimization methods, deterministic and stochastic (simulated annealing), were also assessed. The effectiveness and practicality of each of these combinations were compared.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Innovation (DRI) ITB</dc:publisher>
	<dc:date>2013-12-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jmfs/article/view/300</dc:identifier>
	<dc:identifier>10.5614/itbj.sci.2006.38.2.4</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Mathematical and Fundamental Sciences; Vol. 38 No. 2 (2006); 133-147</dc:source>
	<dc:source>2338-5510</dc:source>
	<dc:source>2337-5760</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jmfs/article/view/300/283</dc:relation>
</oai_dc:dc>