Melola Discovery

← Melola Discovery

Jurnal SINTA 1

QuEChERS Method for the Determination of Pesticide Residues in Indonesian Green Coffee Beans using Liquid Chromatography Tandem Mass Spectrometry

Journal of Mathematical and Fundamental Sciences · Vol. 47 No. 3 (2015) · hlm. 296–308

DOI
10.5614/j.math.fund.sci.2015.47.3.7
ISSN
2338-5510, 2337-5760
Terbit
2015-12-01
Penerbit
Directorate for Research and Innovation (DRI) ITB
Bahasa
eng

Abstrak

A method using QuEChERS sample preparation followed by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESIMS/MS) was developed for quantitative determination of 14 pesticide residues in Indonesian green coffee beans. The European Standard Method EN 15662:2008 was modified to obtain an appropriate extraction and clean-up procedure for green coffee bean samples. Homogenous slurry samples were extracted with 1% acetic acid in acetonitrile and the extracts were cleaned up by a high pigment dispersive SPE. LC-ESI-MS/MS was operated in the MRM mode for two specific precursor-product ion transitions per target compound to obtain 4 identification points. Representative matrix-matched calibration curves were applied to compensate matrix effects. This method was validated according to the requirements of SANCO/12495/2011. Limits of detection (LODs) and limits of quantification (LOQs) were obtained in the ranges of 0.2-2.9 μg kg-1 and 0.8-9.7 μg kg-1 respectively, showing lower values than the maximum residu limits (MRLs) set by importing countries. The method was applied to determine 14 pesticide residues in 181 Indonesian green coffee bean samples that were taken from different regions. Some pesticide residues were found in these samples and detected to be higher than the MRLs.

Kata kunci

Jaringan kolaborasi para penulis

20 penulis · 44 tautan kepenulisan bersama · 26 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Bandung Institute of Technology
  • Universitas Setia Budi
  • University of Indonesia
  • National Nuclear Energy Agency of Indonesia
  • Universitas Halu Oleo
  • Universitas Bhakti Kencana
  • Padjadjaran University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tutus GusdinarBandung Institute of Technology2
Rina HerowatiUniversitas Setia Budi2
Daryono Hadi TjahjonoBandung Institute of Technology2
Aiyi AsnawiUniversitas Bhakti Kencana1
As’ari NawawiBandung Institute of Technology1
Slamet IbrahimBandung Institute of Technology1
I Ketut AdnyanaBandung Institute of Technology1
Chusnul ChotimahUniversity of Indonesia1
Muhayatun SantosoNational Nuclear Energy Agency of Indonesia1
Benny S. LatiefUniversity of Indonesia1
Marlia SinggihBandung Institute of Technology1
Ruslin RuslinUniversitas Halu Oleo1
Muhammad ArbaUniversitas Halu Oleo1
Slamet IbrahiimAfiliasi tidak diketahui1
Rizky Juwita SugihartiNational Nuclear Energy Agency of Indonesia1
Rani MaharaniPadjadjaran University1
Nuraini HarmastutiUniversitas Setia Budi1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jmfs/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">QuEChERS Method for the Determination of Pesticide Residues in Indonesian Green Coffee Beans using Liquid Chromatography Tandem Mass Spectrometry</dc:title>
	<dc:creator>Harmoko, Harmoko</dc:creator>
	<dc:creator>Kartasasmita, Rahmana Emran</dc:creator>
	<dc:creator>Tresnawati, Astika</dc:creator>
	<dc:subject xml:lang="en-US">green coffee beans</dc:subject>
	<dc:subject xml:lang="en-US">LC-ESI-MS/MS</dc:subject>
	<dc:subject xml:lang="en-US">MRM</dc:subject>
	<dc:subject xml:lang="en-US">pesticide residues</dc:subject>
	<dc:subject xml:lang="en-US">QuEChERS.</dc:subject>
	<dc:description xml:lang="en-US">A method using QuEChERS sample preparation followed by liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESIMS/MS) was developed for quantitative determination of 14 pesticide residues in Indonesian green coffee beans. The European Standard Method EN 15662:2008 was modified to obtain an appropriate extraction and clean-up procedure for green coffee bean samples. Homogenous slurry samples were extracted with 1% acetic acid in acetonitrile and the extracts were cleaned up by a high pigment dispersive SPE. LC-ESI-MS/MS was operated in the MRM mode for two specific precursor-product ion transitions per target compound to obtain 4 identification points. Representative matrix-matched calibration curves were applied to compensate matrix effects. This method was validated according to the requirements of SANCO/12495/2011. Limits of detection (LODs) and limits of quantification (LOQs) were obtained in the ranges of 0.2-2.9 μg kg-1 and 0.8-9.7 μg kg-1 respectively, showing lower values than the maximum residu limits (MRLs) set by importing countries. The method was applied to determine 14 pesticide residues in 181 Indonesian green coffee bean samples that were taken from different regions. Some pesticide residues were found in these samples and detected to be higher than the MRLs.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Innovation (DRI) ITB</dc:publisher>
	<dc:date>2015-12-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jmfs/article/view/444</dc:identifier>
	<dc:identifier>10.5614/j.math.fund.sci.2015.47.3.7</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Mathematical and Fundamental Sciences; Vol. 47 No. 3 (2015); 296-308</dc:source>
	<dc:source>2338-5510</dc:source>
	<dc:source>2337-5760</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jmfs/article/view/444/1071</dc:relation>
</oai_dc:dc>