Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Generator Pulsa Arus

Journal of Mathematical and Fundamental Sciences · Vol. 3 No. 4 (2019) · hlm. 181–186

ISSN
2338-5510, 2337-5760
Terbit
2019-02-06
Penerbit
Directorate for Research and Innovation (DRI) ITB
Bahasa
eng

Abstrak

Ichtisar. Dalam penjelidikan mengenai karakteristik suatu arrester, selain mengetahui karakteristik tembus terhadap tegangan pulsa djuga perlu diselidiki sifat2 tahanan non linearnja (lazim dipergunakan Si C) terhadap pulsa arus menentukan tegangan tinggalnja (Rest spanning). Untuk kepentingan ini dipergunakan pulsa arus 5 x 10 μ sec ataupun 10 x 20 μ sec. Disini akan dibahas mengenai parameter2 rangkaian dan faktor2 jang penting diperhatikan dalam perentjanaan suatu generator pulsa arus. Abstract. In order to obtain the performance characteristic of an arrester, besides knowing the breakdown voltage of its gaps it is also necessary to know the behaviour of the non linear value element (usually Si C) with respect to current surges to get a picture of its rest voltage. For this purpose 5 x 10 μ sec or 10 x 20 μ sec current surges are used. The circuit parameters, and some important factors concerning the design of a current surges generator are discussed here.

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jmfs/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Generator Pulsa Arus</dc:title>
	<dc:creator>Tho, Mak Sioe</dc:creator>
	<dc:description xml:lang="en-US">Ichtisar. Dalam penjelidikan mengenai karakteristik suatu arrester, selain mengetahui karakteristik tembus terhadap tegangan pulsa djuga perlu diselidiki sifat2 tahanan non linearnja (lazim dipergunakan Si C) terhadap pulsa arus menentukan tegangan tinggalnja (Rest spanning). Untuk kepentingan ini dipergunakan pulsa arus 5 x 10 μ sec ataupun 10 x 20 μ sec. Disini akan dibahas mengenai parameter2 rangkaian dan faktor2 jang penting diperhatikan dalam perentjanaan suatu generator pulsa arus. Abstract. In order to obtain the performance characteristic of an arrester, besides knowing the breakdown voltage of its gaps it is also necessary to know the behaviour of the non linear value element (usually Si C) with respect to current surges to get a picture of its rest voltage. For this purpose  5 x 10 μ sec or 10 x 20 μ sec current surges are used. The circuit parameters, and some important factors concerning the design of a current surges generator are discussed here.</dc:description>
	<dc:publisher xml:lang="en-US">Directorate for Research and Innovation (DRI) ITB</dc:publisher>
	<dc:date>2019-02-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jmfs/article/view/9773</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Mathematical and Fundamental Sciences; Vol. 3 No. 4 (1965); 181-186</dc:source>
	<dc:source>2338-5510</dc:source>
	<dc:source>2337-5760</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jmfs/article/view/9773/3743</dc:relation>
</oai_dc:dc>