Analysis of Wastewater Management Systems at Bhayangkara Hospital, Palu

Journal of Public Health and Pharmacy · Vol. 1 No. 1 (2021) · hlm. 1–5

DOI
10.56338/jphp.v1i1.3649
ISSN
2775-4952
Terbit
2021-02-25
Penerbit
Pusat Pengembangan Teknologi Informasi dan Jurnal Universitas Muhammadiyah Palu
Bahasa
eng

Abstrak

This study aims to determine the wastewater management system at Bhayangkara Hospital, Palu. In carrying out their activities, hospitals produce liquid waste that can interfere with health. If not handled properly, it will cause harm to society and the environment. The research results at Bhanyangkara Hospital in Palu show that the wastewater management system already has many filters and other control tanks. A cover has accompanied each tub, channeled through an open channel, closed channel, the building is watertight, and the water flows smoothly., already has a Flow Meter device but does not have a fat catcher, especially in the nutrition room, liquid waste in the Laboratory room at the third party to PT. Tenang Jaya Sejahtera until its destruction, the Radiology room has used the CR System, so there is no wastewater because it has used the tool, carries out primary and secondary treatment and supplies tools for treating liquid waste are still not available such as daily pH tools, pH tools handy for measuring the level of acidity/base of a liquid and besides that for the Flow Meter tool is readily available. Suggestions are expected that this study's results are used as input and become useful information, especially for Bhayangkara Hospital in Palu and the people living around Bhayangkara Hospital in Palu to know the impact of wastewater management.

Kata kunci

Jaringan kolaborasi para penulis

4 penulis · 4 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Muhammadiyah Palu
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ni Luh Ayu MeryantiUniversitas Muhammadiyah Palu1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.unismuhpalu.ac.id/index.php/jphp/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of Wastewater Management Systems at Bhayangkara Hospital, Palu  </dc:title>
	<dc:creator>Siti Fatimahi</dc:creator>
	<dc:creator>Miswan</dc:creator>
	<dc:creator>Nur Rismawati </dc:creator>
	<dc:subject xml:lang="en-US">Management</dc:subject>
	<dc:subject xml:lang="en-US">Wastewater</dc:subject>
	<dc:subject xml:lang="en-US">Hospital</dc:subject>
	<dc:description xml:lang="en-US">This study aims to determine the wastewater management system at Bhayangkara Hospital, Palu. In carrying out their activities, hospitals produce liquid waste that can interfere with health. If not handled properly, it will cause harm to society and the environment. The research results at Bhanyangkara Hospital in Palu show that the wastewater management system already has many filters and other control tanks. A cover has accompanied each tub, channeled through an open channel, closed channel, the building is watertight, and the water flows smoothly. , already has a Flow Meter device but does not have a fat catcher, especially in the nutrition room, liquid waste in the Laboratory room at the third party to PT. Tenang Jaya Sejahtera until its destruction, the Radiology room has used the CR System, so there is no wastewater because it has used the tool, carries out primary and secondary treatment and supplies tools for treating liquid waste are still not available such as daily pH tools, pH tools handy for measuring the level of acidity/base of a liquid and besides that for the Flow Meter tool is readily available. Suggestions are expected that this study's results are used as input and become useful information, especially for Bhayangkara Hospital in Palu and the people living around Bhayangkara Hospital in Palu to know the impact of wastewater management.</dc:description>
	<dc:publisher xml:lang="en-US">Pusat Pengembangan Teknologi Informasi dan Jurnal Universitas Muhammadiyah Palu</dc:publisher>
	<dc:date>2021-02-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.unismuhpalu.ac.id/index.php/jphp/article/view/3649</dc:identifier>
	<dc:identifier>10.56338/jphp.v1i1.3649</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Public Health and Pharmacy; Vol. 1 No. 1 (2021); 1-5</dc:source>
	<dc:source>2775-4952</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.unismuhpalu.ac.id/index.php/jphp/article/view/3649/2824</dc:relation>
</oai_dc:dc>