Melola Discovery

← Melola Discovery

Jurnal SINTA 1

The Design and Analysis of DC Electrical Voltage-Current Datalogger Device Implemented on Wind Turbine Control System

Journal of Robotics and Control (JRC) · Vol. 1 No. 3 (2020) · hlm. 75–80

DOI
10.18196/jrc.1317
ISSN
2715-5072, 2715-5056
Terbit
2020-02-26
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

DC electrical voltage - current measuring instrument and data logger is an instrument used to measure the current and voltage generated wind turbine and recording the measurement results. The fuction of this instrument is to activate the dummy load on the wind turbine control system to reduce the voltage that exceeds the safe limit when saving electrical energy. The purpose of this research is to manufacture and analyze DC electrical voltage - current measuring instrument with arduino uno based data logger which is capable to measure DC current and voltage generated by Hybrid Power Plants (PLTH) in Pantai Baru Pandansimo Bantul Yogyakarta, and using metrology method to analyze the degree of uncertainty of the measuring instrument. In this research, heuristic method is used to determine the characteristics of the sensor. Sensor characterization has been done, followed by calibration of measurement instrument to determine the magnitude of the uncertainty of the measurement instrument. The results of this research indicated that the characteristics of voltage sensor (CR5310-300) obtained equation of linear regression y=0.29253x + 0.662, while the current sensor characteristics (WCS1800) obtained equation of linear regression y=0.072978x - 37.2408. After the characterization procedure is done, the measuring instrument callibrated using a traced clampmeter. The calibration results indicated that the voltage sensor has accuracy of 99.99%. Whereas for the current measuring instrument has an uncertainty that is extended at standard current 0 - 9 amperes of 0.316 amperes and at the standard current of 9.7 amperes of 0.317 amperes with an accuracy of 99.98%. Based on the results of this research, can be obtained that current and voltage measuring instrument has good accuracy level.

Jaringan kolaborasi para penulis

40 penulis · 137 tautan kepenulisan bersama · 77 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Airlangga
  • Universitas Gadjah Mada
  • Telkom University
  • Institut Teknologi Sepuluh Nopember
  • Universitas Ma'arif Lampung
  • Nile University
  • Universiti Tenaga Nasional
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
P. VigneshwaranSRM Institute of Science and Technology9
Omar TananeUniversity of Hassan II Casablanca6
Brahmantya Aji PramuditaTelkom University5
Lilik Jamilatul AwalinUniversitas Airlangga5
Sigit Dani PerkasaUniversitas Airlangga5
Mian Usman SattarUniversity of Management and Technology4
Yusrizal AfifUniversitas Airlangga3
Muhammad Akbar SyahbaniUniversitas Airlangga3
Herlambang SetiadiUniversitas Airlangga2
Hafidz Faqih Aldi KusumaUniversitas Airlangga2
Agus MukhlisinUniversitas Airlangga2
Kunal KunalGuru Gobind Singh Indraprastha University2
Ipin PrasojoMuhammadiyah University of Surakarta2
Nishith ShahuGujarat Technological University2
Hendra Ari WinarnoUniversitas Gadjah Mada2
Abdul AbrorUniversitas Airlangga2
Antik Widi AnugrahUniversitas Airlangga2
Eka Fitria NingsihYogyakarta State University2
Muhammad Saidun AnwarUniversitas Ma'arif Lampung2
Choirudin ChoirudinUniversitas Ma'arif Lampung2
Dimas Febriyan PriambodoPoliteknik Siber dan Sandi Negara1
Safaa Najah Saud Al-HumairiAfiliasi tidak diketahui1
Arya Dwi KustiawanUniversitas Airlangga1
Muhammad Rafi Nabil ArsalanUniversitas Airlangga1
Rizki Putra PrastioUniversitas Airlangga1
Mohammad Aldrin ArifinTelkom University1
Porman PangaribuanTelkom University1
Nayu Nurrohma HidayahUniversitas Airlangga1
I Nyoman SutantraInstitut Teknologi Sepuluh Nopember1
Yoga Uta NugrahaInstitut Teknologi Sepuluh Nopember1
Indra SidhartaInstitut Teknologi Sepuluh Nopember1
Estiko RijantoNational Research and Innovation Agency1
Afif Zuhri ArfiantoPoliteknik Perkapalan Negeri Surabaya1
Andrei WidjanarkoUniversitas Gadjah Mada1
Robbi RahimUniversiti Malaysia Perlis1
Geston Bakti MuntohaUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Design and Analysis of DC Electrical Voltage-Current Datalogger Device Implemented on Wind Turbine Control System</dc:title>
	<dc:creator>Murti, Sri</dc:creator>
	<dc:creator>Megantoro, Prisma</dc:creator>
	<dc:creator>Silva, Gabriel De Brito</dc:creator>
	<dc:creator>Maseleno, Andino</dc:creator>
	<dc:description xml:lang="en-US">DC electrical voltage - current measuring instrument and data logger is an instrument used to measure the current and voltage generated wind turbine and recording the measurement results. The fuction of this instrument is to activate the dummy load on the wind turbine control system to reduce the voltage that exceeds the safe limit when saving electrical energy. The purpose of this research is to manufacture and analyze DC electrical voltage - current measuring instrument with arduino uno based data logger which is capable to measure DC current and voltage generated by Hybrid Power Plants (PLTH) in Pantai Baru Pandansimo Bantul Yogyakarta, and using metrology method to analyze the degree of uncertainty of the measuring instrument. In this research, heuristic method is used to determine the characteristics of the sensor. Sensor characterization has been done, followed by calibration of measurement instrument to determine the magnitude of the uncertainty of the measurement instrument. The results of this research indicated that the characteristics of voltage sensor (CR5310-300) obtained equation of linear regression y=0.29253x + 0.662, while the current sensor characteristics (WCS1800) obtained equation of linear regression y=0.072978x - 37.2408. After the characterization procedure is done, the measuring instrument callibrated using a traced clampmeter. The calibration results indicated that the voltage sensor has accuracy of 99.99%. Whereas for the current measuring instrument has an uncertainty that is extended at standard current 0 -  9 amperes of 0.316 amperes and at the standard current of 9.7 amperes of 0.317 amperes with an accuracy of 99.98%. Based on the results of this research, can be obtained that current and voltage measuring instrument has good accuracy level.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2020-02-26</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/7703</dc:identifier>
	<dc:identifier>10.18196/jrc.1317</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 1 No. 3 (2020): May; 75-80</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v1i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/7703/4978</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control</dc:rights>
</oai_dc:dc>