Jurnal
SINTA 1
Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load
Journal of Robotics and Control (JRC) · Vol. 2 No. 2 (2021) · hlm. 98–102
ISSN 2715-5072, 2715-5056
Terbit 2021-03-19
Penerbit Universitas Muhammadiyah Yogyakarta
Bahasa eng
Abstrak
With the potential of low water head energy and relatively small water discharge then it takes a low round generator to be applied to the potential of existing energy. The development of Permanent Magnet Generator (PMG), being an alternative considering the pole construction of the rotor is relatively simple compared to conventional generators, so it is technically required a more number of rotor poles in the effort to lower the speed The nominal dial generator. The purpose of this research is to analyze the 1-phase axial generator performance with varied resistive loads and inductive loads. This research has 4 stages of research: 1). Study literature. 2). Carried out testing tools. 3). Measurement of data retrieval. 4). Data analysis. From this research obtained results from the tools and measurements of the data retrieval of the performance of axial generator 1 phase with inductive and resistive load Vaiasi. Load mounted 15 watts, voltage 35.10, current 0.80, RPM 2550 when load 75 Waat, Voltage 11.50, current 1.54, RPM 2220. From these results can be concluded axial generator 1 phase currents also get bigger but voltage and rpm decreases.
Jaringan kolaborasi para penulis
13 penulis ·
30 tautan kepenulisan bersama
· 8 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Universitas Muhammadiyah Palembang Muhammadiyah University of Yogyakarta KIIT University Afiliasi tidak diketahui
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en-US">Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load</dc:title>
<dc:creator>Saleh, Zulkiffli</dc:creator>
<dc:creator>Apriani, Yosi</dc:creator>
<dc:creator>Karim, Khoirul</dc:creator>
<dc:creator>Aldiansyah, Aldiansyah</dc:creator>
<dc:subject xml:lang="en-US">PLTMH</dc:subject>
<dc:subject xml:lang="en-US">PMG</dc:subject>
<dc:subject xml:lang="en-US">Axial Generator</dc:subject>
<dc:subject xml:lang="en-US">resistive load</dc:subject>
<dc:subject xml:lang="en-US">inductive load.</dc:subject>
<dc:description xml:lang="en-US">With the potential of low water head energy and relatively small water discharge then it takes a low round generator to be applied to the potential of existing energy. The development of Permanent Magnet Generator (PMG), being an alternative considering the pole construction of the rotor is relatively simple compared to conventional generators, so it is technically required a more number of rotor poles in the effort to lower the speed The nominal dial generator. The purpose of this research is to analyze the 1-phase axial generator performance with varied resistive loads and inductive loads. This research has 4 stages of research: 1). Study literature. 2). Carried out testing tools. 3). Measurement of data retrieval. 4). Data analysis. From this research obtained results from the tools and measurements of the data retrieval of the performance of axial generator 1 phase with inductive and resistive load Vaiasi. Load mounted 15 watts, voltage 35.10, current 0.80, RPM 2550 when load 75 Waat, Voltage 11.50, current 1.54, RPM 2220. From these results can be concluded axial generator 1 phase currents also get bigger but voltage and rpm decreases.</dc:description>
<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
<dc:date>2021-03-19</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:format>application/pdf</dc:format>
<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/8268</dc:identifier>
<dc:identifier>10.18196/jrc.2260</dc:identifier>
<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 2 (2021): March; 98-102</dc:source>
<dc:source>2715-5072</dc:source>
<dc:source>2715-5056</dc:source>
<dc:source>10.18196/jrc.v2i2</dc:source>
<dc:language>eng</dc:language>
<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/8268/5619</dc:relation>
<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat DOI
3 sitasi
Crossref
Belum diperiksa
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Saleh, Z., Apriani, Y., Karim, K., & Aldiansyah, A. (2021). Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load. Journal of Robotics and Control (JRC), 2(2), 98–102. https://doi.org/10.18196/jrc.2260
Salin
IEEE
Z. Saleh, Y. Apriani, K. Karim, and A. Aldiansyah, “Analysis of Performance of Permanent Magnet Generator Fluks Axial 1 Phasa with Variation Load,” Journal of Robotics and Control (JRC), vol. 2, no. 2, pp. 98–102, 2021, doi: 10.18196/jrc.2260.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.