Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Adaptive threshold PCA for fault detection and isolation

Journal of Robotics and Control (JRC) · Vol. 2 No. 3 (2021) · hlm. 119–125

DOI
10.18196/jrc.2364
ISSN
2715-5072, 2715-5056
Terbit
2021-05-05
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

Fault diagnosis is an important issue in industrial processes to avoid economic losses, process damage, and to guarantee safe working conditions for the operators. For high scale industrial processes the data-driven based methods are the best solution for process monitoring and fault diagnosis. Thus, in this paper, the principal component analysis is shown to detect and isolate faults. Also, a dynamic threshold is implemented to avoid false alarms because incipient faults are difficult to be detected. As a case of study, the Tennessee Eastman (TE) process is used to apply this strategy because the interaction among five units with internal control loops makes difficult to have an approached model. As results are shown the detection times, for cases where were analyzed incipient faults, the time required for fault detection must be improved, in this work, an adaptive threshold was used to reduce the false alarms but it also increases the detection times. It was concluded that the Q chart gave a better result for fault detection; the isolation times were similar to the detection ones. Two incipient faults could not be detected, the fault detection rate was similar to the shown in literature, but the detection times were better in 35% of the cases, unfortunately for four faults the detection times were bigger than the reported in other papers. It is proposed to help this method with independent component analysis due it is not guaranteed to have a Gaussian distribution in the samples.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 42 tautan kepenulisan bersama · 33 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universidad Politécnica de Pachuca
  • Universitas Ahmad Dahlan
  • Universidad Autónoma del Estado de Hidalgo
  • Universidad Politécnica Metropolitana de Hidalgo
  • Tecnológico Nacional de México
  • King Fahd University of Petroleum and Minerals
  • University of Tripoli
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Alfian Ma’arifUniversitas Ahmad Dahlan2
Magdi S. MahmoudKing Fahd University of Petroleum and Minerals2
Ahmed Jaber AbougarairUniversity of Tripoli1
Edwin Albert UmohAfiliasi tidak diketahui1
Safinta Nurindra RahmadhiaUniversitas Ahmad Dahlan1
Samir LadaciEcole Nationale Polytechnique de Constantine1
Abdullah ÇakanKonya Technical University1
Jonattan Niño ParadaUniversidad de los Llanos1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Adaptive threshold PCA for fault detection and isolation</dc:title>
	<dc:creator>Márquez-Vera, Marco Antonio</dc:creator>
	<dc:creator>López-Ortega, Omar</dc:creator>
	<dc:creator>Ramos-Velasco, Luis Enrique</dc:creator>
	<dc:creator>Rodríguez-Romero, Andrea</dc:creator>
	<dc:creator>Ramos-Fernández, Julio César</dc:creator>
	<dc:creator>Hernández-Salazar, Jorge Adalberto</dc:creator>
	<dc:subject xml:lang="en-US">Fault detection</dc:subject>
	<dc:subject xml:lang="en-US">PCA</dc:subject>
	<dc:subject xml:lang="en-US">incipient faults</dc:subject>
	<dc:description xml:lang="en-US">Fault diagnosis is an important issue in industrial processes to avoid economic losses, process damage, and to guarantee safe working conditions for the operators. For high scale industrial processes the data-driven based methods are the best solution for process monitoring and fault diagnosis. Thus, in this paper, the principal component analysis is shown to detect and isolate faults. Also, a dynamic threshold is implemented to avoid false alarms because incipient faults are difficult to be detected. As a case of study, the Tennessee Eastman (TE) process is used to apply this strategy because the interaction among five units with internal control loops makes difficult to have an approached model. As results are shown the detection times, for cases where were analyzed incipient faults, the time required for fault detection must be improved, in this work, an adaptive threshold was used to reduce the false alarms but it also increases the detection times. It was concluded that the Q chart gave a better result for fault detection; the isolation times were similar to the detection ones. Two incipient faults could not be detected, the fault detection rate was similar to the shown in literature, but the detection times were better in 35% of the cases, unfortunately for four faults the detection times were bigger than the reported in other papers. It is proposed to help this method with independent component analysis due it is not guaranteed to have a Gaussian distribution in the samples.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2021-05-05</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/8826</dc:identifier>
	<dc:identifier>10.18196/jrc.2364</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 3 (2021): May; 119-125</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v2i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/8826/5756</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>