Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Proportional-Integral-Derivative and Linear Quadratic Regulator Control of Direct Current Motor Position using Multi-Turn Based on LabView

Journal of Robotics and Control (JRC) · Vol. 2 No. 4 (2021) · hlm. 332–336

DOI
10.18196/jrc.24102
ISSN
2715-5072, 2715-5056
Terbit
2021-07-01
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

This study accommodates the industry needs in monitoring a control system on a DC motor using LabView. The servomotor, which is usually used for position control, was replaced in this study with a DC motor coupled with a multi-turn potentiometer sensor. The use of DC motors was carried out to reduce actuator prices while maintaining control objectives. The control method used is in the form of Proportional – Integral - Derivative (PID) and optimal control which are then compared with the output. PID tuning is done using the Root Locus method. Meanwhile, for optimal control using the Linear Quadratic Regulation (LQR) approach. Testing was done by looking at the results of direct implementation of the DC motor plant hardware through observations using LabView. By using the right zero variables in the PID control, the best performance is obtained until it can track references. Too large a zero value will result in even greater Steady State Error. The results of optimal control using different Q variables did not provide a significant change. The SSE value shows the same result. The results show that the optimal control can track the reference with lower settling time and overshoot than the PID control. However, the two control methods still produce relatively small Steady State Error.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Jakarta State Polytechnic
  • Bandung Institute of Technology
  • Istanbul University
  • University of Indonesia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Nevra BayhanIstanbul University1
Bernadeta Siti Rahayu PurwantiJakarta State Polytechnic1
Hasvienda Mohammad RidlwanUniversity of Indonesia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Proportional-Integral-Derivative and Linear Quadratic Regulator Control of Direct Current Motor Position using Multi-Turn Based on LabView</dc:title>
	<dc:creator>Handaya, Devi</dc:creator>
	<dc:creator>Fauziah, Resti</dc:creator>
	<dc:subject xml:lang="en-US">labview</dc:subject>
	<dc:subject xml:lang="en-US">monitoring system</dc:subject>
	<dc:subject xml:lang="en-US">position control</dc:subject>
	<dc:subject xml:lang="en-US">PID</dc:subject>
	<dc:subject xml:lang="en-US">optimal</dc:subject>
	<dc:subject xml:lang="en-US">LQR</dc:subject>
	<dc:description xml:lang="en-US">This study accommodates the industry needs in monitoring a control system on a DC motor using LabView. The servomotor, which is usually used for position control, was replaced in this study with a DC motor coupled with a multi-turn potentiometer sensor. The use of DC motors was carried out to reduce actuator prices while maintaining control objectives. The control method used is in the form of Proportional – Integral - Derivative (PID) and optimal control which are then compared with the output. PID tuning is done using the Root Locus method. Meanwhile, for optimal control using the Linear Quadratic Regulation (LQR) approach. Testing was done by looking at the results of direct implementation of the DC motor plant hardware through observations using LabView. By using the right zero variables in the PID control, the best performance is obtained until it can track references. Too large a zero value will result in even greater Steady State Error. The results of optimal control using different Q variables did not provide a significant change. The SSE value shows the same result. The results show that the optimal control can track the reference with lower settling time and overshoot than the PID control. However, the two control methods still produce relatively small Steady State Error.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2021-07-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/10033</dc:identifier>
	<dc:identifier>10.18196/jrc.24102</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 4 (2021): July; 332-336</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v2i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/10033/5834</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>