Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A Sensor Based Assessment Monitoring System for Patients with Neurological Disabilities

Journal of Robotics and Control (JRC) · Vol. 2 No. 6 (2021) · hlm. 489–495

DOI
10.18196/jrc.26127
ISSN
2715-5072, 2715-5056
Terbit
2021-11-08
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

The neurological conditions can cause the disability of upper limb and the rehabilitation therapy can help the patients to restore their upper limb motion. However, the current method for upper limb rehabilitation assessment is very basic. The aim of this work is to develop a system and visualize the information to support the doctors and clinicians in the assessment of upper limb motion of patients who are undertaken neurological rehabilitation. Movement tracking including position and orientation have been tracked and data analysis have been done in both time domain and frequency domain. Furthermore, movement smoothness analysis has been done to obtain more information from patients’ movement recovery. The created information visualization can provide objective measurements of patients’ motion recovery and insightful information and for doctors and clinicians including the frequency analysis and movement smoothness analysis. The findings showed the system is able to provide accurate position within 0.1 cm and orientation tracking within 1 degree and meaningful insights for the assessment of upper limb motion functions in daily rehabilitation assessment by providing doctors and clinicians with visualizations of the objective measurements.

Kata kunci

Jaringan kolaborasi para penulis

Belum ada rekan penulis di Melola.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A Sensor Based Assessment Monitoring System for Patients with Neurological Disabilities</dc:title>
	<dc:creator>Bai, Lu</dc:creator>
	<dc:subject xml:lang="en-US">upper limb rehabilitation</dc:subject>
	<dc:subject xml:lang="en-US">inertial sensing</dc:subject>
	<dc:subject xml:lang="en-US">information visualization</dc:subject>
	<dc:subject xml:lang="en-US">wearable sensors</dc:subject>
	<dc:description xml:lang="en-US">The neurological conditions can cause the disability of upper limb and the rehabilitation therapy can help the patients to restore their upper limb motion. However, the current method for upper limb rehabilitation assessment is very basic. The aim of this work is to develop a system and visualize the information to support the doctors and clinicians in the assessment of upper limb motion of patients who are undertaken neurological rehabilitation. Movement tracking including position and orientation have been tracked and data analysis have been done in both time domain and frequency domain. Furthermore, movement smoothness analysis has been done to obtain more information from patients’ movement recovery. The created information visualization can provide objective measurements of patients’ motion recovery and insightful information and for doctors and clinicians including the frequency analysis and movement smoothness analysis. The findings showed the system is able to provide accurate position within 0.1 cm and orientation tracking within 1 degree and meaningful insights for the assessment of upper limb motion functions in daily rehabilitation assessment by providing doctors and clinicians with visualizations of the objective measurements.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2021-11-08</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/10584</dc:identifier>
	<dc:identifier>10.18196/jrc.26127</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 2 No. 6 (2021): November; 489-495</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v2i6</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/10584/5999</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Journal of Robotics and Control (JRC)</dc:rights>
</oai_dc:dc>