Design of Ventilator with Gas Mixing, Tidal Volume, and Humidifier Parameters

Journal of Robotics and Control (JRC) · Vol. 3 No. 3 (2022) · hlm. 348–353

DOI
10.18196/jrc.v3i3.14510
ISSN
2715-5072, 2715-5056
Terbit
2022-05-01
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

On the ventilator, there are several important parameters, including gas mixing, which functions to mix oxygen with free air, the tidal volume serves to supply mixed air to the patient, respiratory rate is the frequency of breath given to the patient, and the humidifier functions to regulate the temperature of the air given to the patient. In this research, the author intends to design a ventilator device which uses a working system to open and close the valve to distribute air to the patient. This tool uses several sensors: oxygen sensor KE-25F3, flow sensor yf-s201, pressure sensor MPX 5700, and temperature sensor DS 12B20. The tidal volume (VT) has 3 setting values: 700 ml, 500 ml, and 300 ml. The test is carried out by opening and closing the valve. The respiratory rate has 2 settings of 15 and 20 breaths/minute. In addition, the humidifier has 3 setting modes 32, 35, and 40o C. From the test results, the highest error was obtained in the 300 ml tidal volume test, which was 7.20% and in the respiratory rate test, the highest error value was 0%. The test results with the oxygen concentration parameter obtained the largest error value of 0.1% at 100% oxygen concentration. In testing the temperature and humidity parameters, the largest average error was 2.40% at 40o C setting. So, it can be concluded that the tool is feasible to use because of the level of small error and still within the standard calibration tolerance of 15%.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 33 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Muhammadiyah University of Yogyakarta
  • Universitas Negeri Surabaya
  • Rumah Sakit Umum Pusat Dr. Sardjito
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Zaipul RahmatMuhammadiyah University of Yogyakarta1
Djoko SukwonoMuhammadiyah University of Yogyakarta1
Sasmeri SasmeriMuhammadiyah University of Yogyakarta1
Levina Riski PriliaMuhammadiyah University of Yogyakarta1
Bambang UntaraRumah Sakit Umum Pusat Dr. Sardjito1
Muhammad Ahdan Fawwaz NurkholidMuhammadiyah University of Yogyakarta1
Mufti Amir SultanAfiliasi tidak diketahui1
Sudarman SamadAfiliasi tidak diketahui1
Abdul GausAfiliasi tidak diketahui1
Winarno Dwi RahardjoAfiliasi tidak diketahui1
Anisja Noni KartikasariUniversitas Negeri Surabaya1
Hesti Khuzaimah Nurul YusufiyahUniversitas Negeri Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Design of Ventilator with Gas Mixing, Tidal Volume, and Humidifier Parameters</dc:title>
	<dc:creator>Fajrin, Hanifah</dc:creator>
	<dc:creator>Susanto, Edi</dc:creator>
	<dc:creator>Kristianto, Pamela Sandi Agus</dc:creator>
	<dc:creator>Herdiyana, Fery Ferizal</dc:creator>
	<dc:creator>Wibowo, Susilo Ari</dc:creator>
	<dc:subject xml:lang="en-US">gas mixing</dc:subject>
	<dc:subject xml:lang="en-US">tidal volume</dc:subject>
	<dc:subject xml:lang="en-US">humidity</dc:subject>
	<dc:subject xml:lang="en-US">ventilator</dc:subject>
	<dc:description xml:lang="en-US">On the ventilator, there are several important parameters, including gas mixing, which functions to mix oxygen with free air, the tidal volume serves to supply mixed air to the patient, respiratory rate is the frequency of breath given to the patient, and the humidifier functions to regulate the temperature of the air given to the patient. In this research, the author intends to design a ventilator device which uses a working system to open and close the valve to distribute air to the patient. This tool uses several sensors: oxygen sensor KE-25F3, flow sensor yf-s201, pressure sensor MPX 5700, and temperature sensor DS 12B20. The tidal volume (VT) has 3 setting values: 700 ml, 500 ml, and 300 ml. The test is carried out by opening and closing the valve. The respiratory rate has 2 settings of 15 and 20 breaths/minute. In addition, the humidifier has 3 setting modes 32, 35, and 40o C. From the test results, the highest error was obtained in the 300 ml tidal volume test, which was 7.20% and in the respiratory rate test, the highest error value was 0%. The test results with the oxygen concentration parameter obtained the largest error value of 0.1% at 100% oxygen concentration. In testing the temperature and humidity parameters, the largest average error was 2.40% at 40o C setting. So, it can be concluded that the tool is feasible to use because of the level of small error and still within the standard calibration tolerance of 15%.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2022-05-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/14510</dc:identifier>
	<dc:identifier>10.18196/jrc.v3i3.14510</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 3 No. 3 (2022): May; 348-353</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v3i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/14510/7397</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 Hanifah Fajrin</dc:rights>
</oai_dc:dc>