Direct Comparison using Coulomb Counting and Open Circuit Voltage Method for the State of Health Li-Po Battery

Journal of Robotics and Control (JRC) · Vol. 3 No. 4 (2022) · hlm. 455–463

DOI
10.18196/jrc.v3i4.15515
ISSN
2715-5072, 2715-5056
Terbit
2022-07-01
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

Electric cars have undergone many developments in the current digital era. This is to avoid the use of increasingly scarce fuel. Recent studies on electric cars show that battery estimation is an interesting topic to be implemented directly. The battery estimation strategy is carried out by the Battery Management System (BMS). BMS is an indispensable part of electric vehicles or hybrid vehicles to ensure optimal and reliable operation of regulating, monitoring, and protecting batteries. A reliable BMS can extend battery life by setting voltage, temperature, and charging and discharging current limits. The main estimation strategy used by BMS is battery fault, SOH, and battery life. Battery State of Health (SOH) is part of the information provided by the BMS to avoid battery damage and failure. SOC is the proportion of battery capacity SOH is a measure of battery health. This study aims to develop a method for estimating SOH simultaneously using Coulomb Counting and Open Circuit Voltage (OCV) algorithms. The battery is modeled to obtain battery parameters and components of internal resistance, capacitance polarization and OCV voltage source. Several tests were implemented in this research by applying the constant current (CC)-charge CC-discharge test. The state-space system is then formed to apply the Coulomb Counting and OCV algorithms so that SOH can be estimated simultaneously. The OCV-SOC function is obtained in the form of a tenth order polynomial and the battery model parameters say that these parameters change with the health of the battery. The results of the model validation are able to accurately model the battery with an average relative error of 0.027%. Coulomb Counting resulted in an accurate SOH estimation with an error of 3.4%.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 59 tautan kepenulisan bersama · 20 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Telkom Surabaya
  • Telkom University
  • Islamic University of Riau
  • Muhammadiyah University of Yogyakarta
  • Universitas Ahmad Dahlan
  • Universitas Sebelas Maret
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Dimas AdiputraInstitut Teknologi Telkom Surabaya1
Ardiansyah Al FarouqInstitut Teknologi Telkom Surabaya1
Khodijah AmirohAfiliasi tidak diketahui1
Ardiansyah Al FarouqAfiliasi tidak diketahui1
Isa HafidzInstitut Teknologi Telkom Surabaya1
Robin Addwiyansyah Alfaro SamratAfiliasi tidak diketahui1
Aditya YudhistiraAfiliasi tidak diketahui1
Ahmad HabibiAfiliasi tidak diketahui1
Muhammad Adib KamaliInstitut Teknologi Telkom Surabaya1
Hari MaghfirohUniversitas Sebelas Maret1
Alfian Ma’arifUniversitas Ahmad Dahlan1
Iswanto SuwarnoMuhammadiyah University of Yogyakarta1
Furizal FurizalIslamic University of Riau1
Aqsha Al Madani KurniawanTelkom University1
Moch. Iskandar RiansyahInstitut Teknologi Telkom Surabaya1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Direct Comparison using Coulomb Counting and Open Circuit Voltage Method for the State of Health Li-Po Battery</dc:title>
	<dc:creator>Amifia, Lora Khaula</dc:creator>
	<dc:subject xml:lang="en-US">State of Health (SOH)</dc:subject>
	<dc:subject xml:lang="en-US">Coulomb Counting</dc:subject>
	<dc:subject xml:lang="en-US">Open Circuit Voltage (OCV)</dc:subject>
	<dc:description xml:lang="en-US">Electric cars have undergone many developments in the current digital era. This is to avoid the use of increasingly scarce fuel. Recent studies on electric cars show that battery estimation is an interesting topic to be implemented directly. The battery estimation strategy is carried out by the Battery Management System (BMS). BMS is an indispensable part of electric vehicles or hybrid vehicles to ensure optimal and reliable operation of regulating, monitoring, and protecting batteries. A reliable BMS can extend battery life by setting voltage, temperature, and charging and discharging current limits. The main estimation strategy used by BMS is battery fault, SOH, and battery life. Battery State of Health (SOH) is part of the information provided by the BMS to avoid battery damage and failure. SOC is the proportion of battery capacity SOH is a measure of battery health. This study aims to develop a method for estimating SOH simultaneously using Coulomb Counting and Open Circuit Voltage (OCV) algorithms. The battery is modeled to obtain battery parameters and components of internal resistance, capacitance polarization and OCV voltage source. Several tests were implemented in this research by applying the constant current (CC)-charge CC-discharge test. The state-space system is then formed to apply the Coulomb Counting and OCV algorithms so that SOH can be estimated simultaneously. The OCV-SOC function is obtained in the form of a tenth order polynomial and the battery model parameters say that these parameters change with the health of the battery. The results of the model validation are able to accurately model the battery with an average relative error of 0.027%. Coulomb Counting resulted in an accurate SOH estimation with an error of 3.4%.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2022-07-01</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/15515</dc:identifier>
	<dc:identifier>10.18196/jrc.v3i4.15515</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 3 No. 4 (2022): July; 455-463</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v3i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/15515/7628</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 lora Khaula amifia</dc:rights>
</oai_dc:dc>