Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Single Lead EMG signal to Control an Upper Limb Exoskeleton Using Embedded Machine Learning on Raspberry Pi

Journal of Robotics and Control (JRC) · Vol. 4 No. 1 (2023) · hlm. 35–45

DOI
10.18196/jrc.v4i1.17364
ISSN
2715-5072, 2715-5056
Terbit
2023-02-09
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

Post-stroke can cause partial or complete paralysis of the human limb. Delayed rehabilitation steps in post-stroke patients can cause muscle atrophy and limb stiffness. Post-stroke patients require an upper limb exoskeleton device for the rehabilitation process. Several previous studies used more than one electrode lead to control the exoskeleton. The use of many electrode leads can lead to an increase in complexity in terms of hardware and software. Therefore, this research aims to develop single lead EMG pattern recognition to control an upper limb exoskeleton. The main contribution of this research is that the robotic upper limb exoskeleton device can be controlled using a single lead EMG. EMG signals were tapped at the biceps point with a sampling frequency of 2000 Hz. A Raspberry Pi 3B+ was used to embed the data acquisition, feature extraction, classification and motor control by using multithread algorithm. The exoskeleton arm frame is made using 3D printing technology using a high torque servo motor drive. The control process is carried out by extracting EMG signals using EMG features (mean absolute value, root mean square, variance) further extraction results will be trained on machine learning (decision tree (DT), linear regression (LR), polynomial regression (PR), and random forest (RF)). The results show that machine learning decision tree and random forest produce the highest accuracy compared to other classifiers. The accuracy of DT and RF are of 96.36±0.54% and 95.67±0.76%, respectively. Combining the EMG features, shows that there is no significant difference in accuracy (p-value >0.05). A single lead EMG electrode can control the upper limb exoskeleton robot device well.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 101 tautan kepenulisan bersama · 45 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Poltekkes Kemenkes Surabaya
  • University of Pembangunan Nasional Veteran Jawa Timur
  • Padjadjaran University
  • IPB University
  • Universitas Trunodjoyo Madura
  • Universiti Brunei Darussalam
  • Azerbaijan State Oil and Industry University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Sari LuthfiyahPoltekkes Kemenkes Surabaya4
Wahyu LestariUniversity of Pembangunan Nasional Veteran Jawa Timur2
Grzegorz KrólczykOpole University of Technology2
Endro YuliantoPoltekkes Kemenkes Surabaya1
Umaimah Mitsalia Ummi SalwaUniversitas Airlangga1
Tri Bowo IndartoPoltekkes Kemenkes Surabaya1
Hanny HafiarPadjadjaran University1
Syauqy LukmanAustralian National University1
Putri LimiliaPadjadjaran University1
Kholidil AminPadjadjaran University1
Karlisa PriandanaIPB University1
Agus BuonoIPB University1
Cholid MawardiIPB University1
Triana RahmawatiAfiliasi tidak diketahui1
I Putu Alit PawanaRumah Sakit Dokter Soetomo1
Bedjo UtomoPoltekkes Kemenkes Surabaya1
Sugeng Iwan SetyobudiPoltekkes Kemenkes Malang1
Sumber SumberPoltekkes Kemenkes Surabaya1
Endang Dian SetioningsihPoltekkes Kemenkes Surabaya1
Roichatun NashichahPoltekkes Kemenkes Surabaya1
Vijay Anant AthavaleAfiliasi tidak diketahui1
Alfian Ma’arifUniversitas Ahmad Dahlan1
Iswanto SuwarnoMuhammadiyah University of Yogyakarta1
Faikul UmamUniversitas Trunodjoyo Madura1
Muhammad FuadUniversitas Trunodjoyo Madura1
Vugar AbdullayevAfiliasi tidak diketahui1
Abd KholiqAfiliasi tidak diketahui1
Lamidi LamidiAfiliasi tidak diketahui1
Farid AmrinsaniAfiliasi tidak diketahui1
Hafizh Aushaf MahdyAfiliasi tidak diketahui1
Ragimova NazilaAfiliasi tidak diketahui1
Eva Yulia PuspaningrumUniversity of Pembangunan Nasional Veteran Jawa Timur1
I Gede Susrama Mas DiyasaUniversity of Pembangunan Nasional Veteran Jawa Timur1
Sayyidah HumairahUniversity of Pembangunan Nasional Veteran Jawa Timur1
Fara Disa DurryUniversity of Pembangunan Nasional Veteran Jawa Timur1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Single Lead EMG signal to Control an Upper Limb Exoskeleton Using Embedded Machine Learning on Raspberry Pi</dc:title>
	<dc:creator>Triwiyanto, Triwiyanto</dc:creator>
	<dc:creator>Caesarendra, Wahyu</dc:creator>
	<dc:creator>Abdullayev, Vugar</dc:creator>
	<dc:creator>Ahmed, Abdussalam Ali</dc:creator>
	<dc:creator>Herianto, Herianto</dc:creator>
	<dc:subject xml:lang="en-US">Upper limb exoskeleton</dc:subject>
	<dc:subject xml:lang="en-US">EMG signal</dc:subject>
	<dc:subject xml:lang="en-US">Raspberry Pi</dc:subject>
	<dc:subject xml:lang="en-US">machine learning</dc:subject>
	<dc:subject xml:lang="en-US">multi-thread</dc:subject>
	<dc:description xml:lang="en-US">Post-stroke can cause partial or complete paralysis of the human limb. Delayed rehabilitation steps in post-stroke patients can cause muscle atrophy and limb stiffness. Post-stroke patients require an upper limb exoskeleton device for the rehabilitation process. Several previous studies used more than one electrode lead to control the exoskeleton. The use of many electrode leads can lead to an increase in complexity in terms of hardware and software. Therefore, this research aims to develop single lead EMG pattern recognition to control an upper limb exoskeleton. The main contribution of this research is that the robotic upper limb exoskeleton device can be controlled using a single lead EMG. EMG signals were tapped at the biceps point with a sampling frequency of 2000 Hz. A Raspberry Pi 3B+ was used to embed the data acquisition, feature extraction, classification and motor control by using multithread algorithm. The exoskeleton arm frame is made using 3D printing technology using a high torque servo motor drive. The control process is carried out by extracting EMG signals using EMG features (mean absolute value, root mean square, variance) further extraction results will be trained on machine learning (decision tree (DT), linear regression (LR), polynomial regression (PR), and random forest (RF)). The results show that machine learning decision tree and random forest produce the highest accuracy compared to other classifiers. The accuracy of DT and RF are of 96.36±0.54% and 95.67±0.76%, respectively. Combining the EMG features, shows that there is no significant difference in accuracy (p-value &amp;gt;0.05). A single lead EMG electrode can control the upper limb exoskeleton robot device well.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2023-02-09</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/17364</dc:identifier>
	<dc:identifier>10.18196/jrc.v4i1.17364</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 4 No. 1 (2023); 35-45</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v4i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/17364/8107</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Triwiyanto Triwiyanto, Wahyu Caesarendra, Vugar Abdullayev, Abdussalam Ali Ahmed, Herianto Herianto</dc:rights>
</oai_dc:dc>