Melola Discovery

← Melola Discovery

Jurnal SINTA 1

A Novel Variable Stiffness Compound Extensor-Pneumatic Artificial Muscle (CE-PAM): Design and Mathematical Model

Journal of Robotics and Control (JRC) · Vol. 4 No. 3 (2023) · hlm. 342–355

DOI
10.18196/jrc.v4i3.18225
ISSN
2715-5072, 2715-5056
Terbit
2023-06-02
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

Pneumatic artificial muscles (PAMs) have been exploited in robots utilized in various fields, including industry and medicine, due to their numerous advantages, such as their light weight; smooth, fast responses; and ability to generate significant force when fully extended. The actuator’s stiffness is important in these applications, and extensor PAMs (EPAMs) have a lower stiffness when compared to contractor PAMs (CPAMs). Because of this, this research presents the compound extensor PAM (CE-PAM), which is a novel actuator that has higher stiffness and can alter its stiffness at a fixed length or maintain a fixed stiffness at a variable length. This makes it useful in applications such as surgery robots and wearable robots. The CE-PAM is created by inserting the CPAM into the EPAM. Then, a mathematical model is developed to calculate the output force using several mathematical equations that relate the force, actuator size, and applied pressure to each other. The force is also calculated experimentally, and when comparing the mathematical with the experimental results, the error percentage appears greater than 20%. So the mathematical model is enhanced by calculating the wasted energy consumed by the actuator before the start of the bladder’s expansion, at which the force is zero because the pressure is consumed only for bladder expansion to touch the sleeve. The effect of the bladder’s thickness is calculated to further enhance the model by calculating the volume of air entering the muscle rather than the total muscle volume. To illustrate the effect of thickness on the actuator, experiments are conducted on CPAMs made of the same bladder material but with different thicknesses. A balloon is used in the manufacture of the bladder. Because it is a lightweight, thin material with a low thickness, it requires very low pressure to expand.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Basrah
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">A Novel Variable Stiffness Compound Extensor-Pneumatic Artificial Muscle (CE-PAM): Design and Mathematical Model</dc:title>
	<dc:creator>Al-Mayahi, Wafaa</dc:creator>
	<dc:creator>Al-Fahaam, Hassanin</dc:creator>
	<dc:subject xml:lang="en-US">Soft Robot</dc:subject>
	<dc:subject xml:lang="en-US">Soft Actuator</dc:subject>
	<dc:subject xml:lang="en-US">Pneumatic Artificial Muscle (PAM)</dc:subject>
	<dc:subject xml:lang="en-US">Modeling</dc:subject>
	<dc:subject xml:lang="en-US">Variable Stiffness.</dc:subject>
	<dc:description xml:lang="en-US">Pneumatic artificial muscles (PAMs) have been exploited in robots utilized in various fields, including industry and medicine, due to their numerous advantages, such as their light weight; smooth, fast responses; and ability to generate significant force when fully extended. The actuator’s stiffness is important in these applications, and extensor PAMs (EPAMs) have a lower stiffness when compared to contractor PAMs (CPAMs). Because of this, this research presents the compound extensor PAM (CE-PAM), which is a novel actuator that has higher stiffness and can alter its stiffness at a fixed length or maintain a fixed stiffness at a variable length. This makes it useful in applications such as surgery robots and wearable robots. The CE-PAM is created by inserting the CPAM into the EPAM. Then, a mathematical model is developed to calculate the output force using several mathematical equations that relate the force, actuator size, and applied pressure to each other. The force is also calculated experimentally, and when comparing the mathematical with the experimental results, the error percentage appears greater than 20%. So the mathematical model is enhanced by calculating the wasted energy consumed by the actuator before the start of the bladder’s expansion, at which the force is zero because the pressure is consumed only for bladder expansion to touch the sleeve. The effect of the bladder’s thickness is calculated to further enhance the model by calculating the volume of air entering the muscle rather than the total muscle volume. To illustrate the effect of thickness on the actuator, experiments are conducted on CPAMs made of the same bladder material but with different thicknesses. A balloon is used in the manufacture of the bladder. Because it is a lightweight, thin material with a low thickness, it requires very low pressure to expand.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2023-06-02</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/18225</dc:identifier>
	<dc:identifier>10.18196/jrc.v4i3.18225</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 4 No. 3 (2023); 342-355</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v4i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/18225/8398</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Wafaa Al-Mayahi, Hassanin Al-Fahaam</dc:rights>
</oai_dc:dc>