Melola Discovery

← Melola Discovery

Jurnal SINTA 1

An Accurate Efficiency Calculation for PMSG Utilized in Renewable Energy Systems

Journal of Robotics and Control (JRC) · Vol. 4 No. 4 (2023) · hlm. 458–465

DOI
10.18196/jrc.v4i4.18441
ISSN
2715-5072, 2715-5056
Terbit
2023-07-06
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng

Abstrak

Considering the importance of optimizing renewable energy systems, this paper aims at calculating the exact efficiency of a stand-alone wind turbine connected to a synchronous generator with permanent magnet excitation (PMSG). By accounting for mechanical and electrical losses (copper losses, stray load losses, iron core losses, friction losses, windings losses, and magnetizing saturation effect), the study investigates the impact of wind speed on the generator's performance and efficiency in addition to the impact of losses on the overall efficiency of (PMSG). The simulation of the PMSG dynamic model 8.5×(10)^3 V․A is executed using MATLAB/Simulink, employing a simplified equivalent circuit that accurately represents the PMSG's behavior under steady-state conditions with resistive loads. Wind speeds of 12 and 14 meters/second are chosen as fixed values to demonstrate the effect of varying wind speed on efficiency. The obtained results reveal the influence of wind speed on the PMSG efficiency. The presented findings contribute to the understanding of PMSG performance and can aid in optimizing the stand-alone wind turbine systems, they also show that the wind had an effect on the efficiency values that were obtained (97.86% at 12m/s and 97.91% at 14 m/s), while the effect of losses was very few around 3%. However, the obtained results are very good compared to previous studies to show the accuracy and validity of the suggested dynamic model.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 6 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Northern Technical University
  • Altınbaş University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed Ahmed KhalafNorthern Technical University1
Kutaiba Khalaf KhaleelNorthern Technical University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">An Accurate Efficiency Calculation for PMSG Utilized in Renewable Energy Systems</dc:title>
	<dc:creator>Hamodat, Zaid</dc:creator>
	<dc:creator>Hussein, Ismail Khudhur</dc:creator>
	<dc:creator>Nasir, Bilal Abdullah</dc:creator>
	<dc:subject xml:lang="en-US">PMSG</dc:subject>
	<dc:subject xml:lang="en-US">Synchronous Generator</dc:subject>
	<dc:subject xml:lang="en-US">Wind Speed Effect</dc:subject>
	<dc:subject xml:lang="en-US">Stand-Alone Wind Turbine</dc:subject>
	<dc:subject xml:lang="en-US">Efficiency Calculations.</dc:subject>
	<dc:description xml:lang="en-US">Considering the importance of optimizing renewable energy systems, this paper aims at calculating the exact efficiency of a stand-alone wind turbine connected to a synchronous generator with permanent magnet excitation (PMSG). By accounting for mechanical and electrical losses (copper losses, stray load losses, iron core losses, friction losses, windings losses, and magnetizing saturation effect), the study investigates the impact of wind speed on the generator's performance and efficiency in addition to the impact of losses on the overall efficiency of (PMSG). The simulation of the PMSG dynamic model 8.5×(10)^3 V․A is executed using MATLAB/Simulink, employing a simplified equivalent circuit that accurately represents the PMSG's behavior under steady-state conditions with resistive loads. Wind speeds of 12 and 14 meters/second are chosen as fixed values to demonstrate the effect of varying wind speed on efficiency. The obtained results reveal the influence of wind speed on the PMSG efficiency. The presented findings contribute to the understanding of PMSG performance and can aid in optimizing the stand-alone wind turbine systems, they also show that the wind had an effect on the efficiency values that were obtained (97.86% at 12m/s and 97.91% at 14 m/s), while the effect of losses was very few around 3%. However, the obtained results are very good compared to previous studies to show the accuracy and validity of the suggested dynamic model.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2023-07-06</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/18441</dc:identifier>
	<dc:identifier>10.18196/jrc.v4i4.18441</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 4 No. 4 (2023); 458-465</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:source>10.18196/jrc.v4i4</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/18441/8473</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 Zaid Hamodat, Ismail Khudhur Hussein, Bilal Abdullah Nasir</dc:rights>
</oai_dc:dc>