Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Early Detection of Short Circuit Faults Between Windings in Distribution Transformers Using Finite Element Method

Journal of Robotics and Control (JRC) · Vol. 6 No. 4 (2025) · hlm. 2095–2108

DOI
10.18196/jrc.v6i4.26004
ISSN
2715-5072, 2715-5056
Terbit
2025-08-10
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The primary aim and contribution of this study is the presentation of a non-intrusive early diagnosis method based on finite element simulation (FEM). The focus was on a 1000 kVA distribution transformer based on manufacturing data and field tests conducted in Mosul, Iraq. An accurate two-dimensional model of the transformer was developed using ANSYS Maxwell software, simulating normal operation and various internal fault scenarios (such as single-phase or double-phase short-circuits and ground faults) at varying rates. The resulting changes in magnetic flux distribution, core losses, currents, and voltages were analyzed as indicators to determine the presence, type, and severity of faults. A representation of internal faults in the three-phase transformer windings was performed to detect and diagnose faults early. The results clearly show that small short-circuit faults (up to 1.2% of the windings) are distinguishable by specific changes in transformer parameters. These faults lead to a localized temperature increase and the onset of insulation deterioration. It was also observed that an increase in the fault percentage (5% to 25%) causes a significant increase in magnetic flux and total losses. These effects are significantly exacerbated by ground faults or faults involving two phases. These results confirm that computational analysis provides a powerful tool for proactive monitoring, enabling preventive maintenance scheduling based on initial fault indications. This contributes to extending transformer life, enhancing network reliability, and avoiding costly catastrophic failures. Continuous monitoring and effective ground protection remain critical elements for maintaining transformer safety and efficiency.

Kata kunci

Jaringan kolaborasi para penulis

12 penulis · 18 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Mosul
  • Universiti Sains Malaysia
  • University of Technology Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Wisam NajemUniversity of Mosul1
Shaker Mahmood KhudherUniversity of Mosul1
Anas MustafaUniversity of Mosul1
Karam Khairullah MohammedUniversity of Technology Malaysia1
Ali AbbawiUniversity of Mosul1
Ibrahim Ismael AlnaibUniversity of Mosul1
Hiba Nadhim A. Al-KaoazUniversity of Mosul1
Mohd Fadzil AinUniversiti Sains Malaysia1
Mohamad Kamarol Mohd JamilUniversiti Sains Malaysia1
Mazyed A. Al-TakUniversiti Sains Malaysia1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Early Detection of Short Circuit Faults Between Windings in Distribution Transformers Using Finite Element Method</dc:title>
	<dc:creator>Aljammal, Mustafa Thaer</dc:creator>
	<dc:creator>Alyozbaky, Omar Sh.</dc:creator>
	<dc:subject xml:lang="en-US">Distribution Transformers</dc:subject>
	<dc:subject xml:lang="en-US">Internal Short Circuit Fault Simulation</dc:subject>
	<dc:subject xml:lang="en-US">Finite Element Method (FEM)</dc:subject>
	<dc:subject xml:lang="en-US">ANSYS Maxwell Software</dc:subject>
	<dc:subject xml:lang="en-US">Magnetic Flux Distribution Analysis</dc:subject>
	<dc:subject xml:lang="en-US">Predictive Fault Diagnosis</dc:subject>
	<dc:description xml:lang="en-US">The primary aim and contribution of this study is the presentation of a non-intrusive early diagnosis method based on finite element simulation (FEM). The focus was on a 1000 kVA distribution transformer based on manufacturing data and field tests conducted in Mosul, Iraq. An accurate two-dimensional model of the transformer was developed using ANSYS Maxwell software, simulating normal operation and various internal fault scenarios (such as single-phase or double-phase short-circuits and ground faults) at varying rates. The resulting changes in magnetic flux distribution, core losses, currents, and voltages were analyzed as indicators to determine the presence, type, and severity of faults. A representation of internal faults in the three-phase transformer windings was performed to detect and diagnose faults early. The results clearly show that small short-circuit faults (up to 1.2% of the windings) are distinguishable by specific changes in transformer parameters. These faults lead to a localized temperature increase and the onset of insulation deterioration. It was also observed that an increase in the fault percentage (5% to 25%) causes a significant increase in magnetic flux and total losses. These effects are significantly exacerbated by ground faults or faults involving two phases. These results confirm that computational analysis provides a powerful tool for proactive monitoring, enabling preventive maintenance scheduling based on initial fault indications. This contributes to extending transformer life, enhancing network reliability, and avoiding costly catastrophic failures. Continuous monitoring and effective ground protection remain critical elements for maintaining transformer safety and efficiency.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2025-08-10</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/26004</dc:identifier>
	<dc:identifier>10.18196/jrc.v6i4.26004</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 6 No. 4 (2025); 2095-2108</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/26004/11810</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 Aljammal , Omar Sh. Alyozbaky</dc:rights>