Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Analysis of Control Strategy Development: Backstepping and Classical Regulators for Power Regulation in a Wind Turbine System

Journal of Robotics and Control (JRC) · Vol. 7 No. 1 (2026) · hlm. 3333–3342

DOI
10.18196/jrc.v7i1.27077
ISSN
2715-5072, 2715-5056
Terbit
2026-03-13
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Optimising the control of wind power systems based on Doubly-Fed Induction Generators (DFIG) raises complex technical challenges, intrinsically linked to the non-linear natureof these machines. With this in mind, this study presents a comparison of two distinct control approaches: Proportional-Integral (PI) control, and Backstepping control, designed specifically to address the challenges posed by unstable and variable dynamics.The methodological approach is based on a DFIG model built on the foundations of vector control. This theoretical framework is implemented into a MATLAB/Simulink environment. Backstepping control, in particular, is stabilised by means of a rigorous construction of the Lyapunov function, guaranteeing error convergence and robustness in the face of disturbances. The simulation results highlight the differences in performance. Whilethe classic PI control approach is robust to parametric variations, it results in a slower response time (27.6 ms) and higher static error (0.2%). Its simple structure and efficient implementation make it a reliable choice in industrial environments with limitedresources. In contrast, the Backstepping method significantly reduces overshoot, improves system response time (0.18 ms), and achieves a notable reduction in static error (0.064%), demonstrating its superiority in dynamic and unstable environments. This approach excels in managing the non-linearities inherent in wind energy systems, giving it a clear advantage in unstable or fluctuating environments. In short, this study does not simply juxtapose two methods; it outlines the future of more adaptive, more responsive control. While PI remains a faithful ally in simplicity, Backstepping technology offers a promising approachto the development of smart energy systems.

Kata kunci

Jaringan kolaborasi para penulis

14 penulis · 50 tautan kepenulisan bersama · 23 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Sidi Mohamed Ben Abdellah University
  • Université Ibn Zohr
  • Université Hassan 1er
  • University of Hassan II Casablanca
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Mohammed Khalil LaghraibSidi Mohamed Ben Abdellah University11
Aymane AmalaouiSidi Mohamed Ben Abdellah University11
Souhail BarakatUniversity of Hassan II Casablanca5
Azeddine MouhsenUniversité Hassan 1er1
Mustapha AlaouiUniversité Hassan 1er1
Hattab MakerUniversité Hassan 1er1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of Control Strategy Development: Backstepping and Classical Regulators for Power Regulation in a Wind Turbine System</dc:title>
	<dc:creator>Mbarek Chahboun</dc:creator>
	<dc:creator>Ali Ait Ali</dc:creator>
	<dc:creator>Mohcine Abouyaakoub</dc:creator>
	<dc:creator>Aziz El Mrabet</dc:creator>
	<dc:creator>Hicham Hihi</dc:creator>
	<dc:creator>Youssef El Bid</dc:creator>
	<dc:creator>Kamal Boujaghama</dc:creator>
	<dc:creator>Youssef Ouhassan</dc:creator>
	<dc:subject xml:lang="en-US">Backstepping Control</dc:subject>
	<dc:subject xml:lang="en-US">Doubly Fed Induction Generator (DFIG)</dc:subject>
	<dc:subject xml:lang="en-US">Nonlinear Control</dc:subject>
	<dc:subject xml:lang="en-US">Proportional-Integral (PI)</dc:subject>
	<dc:subject xml:lang="en-US">Robust Control</dc:subject>
	<dc:description xml:lang="en-US">Optimising the control of wind power systems based on Doubly-Fed Induction Generators (DFIG) raises complex technical challenges, intrinsically linked to the non-linear natureof these machines. With this in mind, this study presents a comparison of two distinct control approaches: Proportional-Integral (PI) control, and Backstepping control, designed specifically to address the challenges posed by unstable and variable dynamics.The methodological approach is based on a DFIG model built on the foundations of vector control. This theoretical framework is implemented into a MATLAB/Simulink environment. Backstepping control, in particular, is stabilised by means of a rigorous construction of the Lyapunov function, guaranteeing error convergence and robustness in the face of disturbances. The simulation results highlight the differences in performance. Whilethe classic PI control approach is robust to parametric variations, it results in a slower response time (27.6 ms) and higher static error (0.2%). Its simple structure and efficient implementation make it a reliable choice in industrial environments with limitedresources. In contrast, the Backstepping method significantly reduces overshoot, improves system response time (0.18 ms), and achieves a notable reduction in static error (0.064%), demonstrating its superiority in dynamic and unstable environments. This approach excels in managing the non-linearities inherent in wind energy systems, giving it a clear advantage in unstable or fluctuating environments. In short, this study does not simply juxtapose two methods; it outlines the future of more adaptive, more responsive control. While PI remains a faithful ally in simplicity, Backstepping technology offers a promising approachto the development of smart energy systems.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2026-03-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/27077</dc:identifier>
	<dc:identifier>10.18196/jrc.v7i1.27077</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 7 No. 1 (2026); 3333-3342</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/27077/12273</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Mbarek Chahboun, Ali Ait Ali, Mohcine Abouyaakoub, Aziz El Mrabet, Hicham Hihi, Youssef El Bid, Kamal Boujaghama, Youssef Ouhassan</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>