Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Implementation of Adaptive Hysteresis-Band Current Control for Bidirectional H-Bridge DC-DC Converter

Journal of Robotics and Control (JRC) · Vol. 6 No. 6 (2026) · hlm. 3099–3113

DOI
10.18196/jrc.v6i6.27096
ISSN
2715-5072, 2715-5056
Terbit
2026-01-26
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

The substantial adoption of electric vehicles (EVs) has the potential to disrupt the power grid due to uncontrolled charging. A promising solution is Vehicle-to-Grid (V2G) technology, which allows EVs to return surplus energy to the grid to maintain reliability. However, a key challenge is developing a bidirectional converter with a rapid response that can also maintain a constant switching frequency to avoid harmonic disturbances. This study introduces an innovative adaptive hysteresis bandwidth current control method for H-bridge converters. This method provides a rapid and precise response to dynamic current and voltage fluctuations while maintaining a constant switching frequency for the MOSFET. The adaptive bandwidth values are mathematically derived from converter principles and implemented via a lookup table in a microcontroller. The simulation results showed a response time of less than 1 millisecond without overshoot. Experimental validation demonstrated the system’s efficacy in maintaining a constant switching frequency under dynamic changes. In charging mode, the average frequency was 14.88 kHz (with a range of 0.79 kHz), and the efficiency was 85.74%, while the fixed hysteresis band has a frequency variation of 14.26 kHz to 20.66 kHz (with a range of 6.37 kHz). In discharge mode, the average frequency was 16.62 kHz (with a range of 0.33 kHz), the efficiency was 77.40%, and the fixed bandwidth is approximately 2.3 kHz on frequency from 15.82 kHz to 18.12 kHz. With adaptive control, the frequency change range is successfully constant with a small range.

Kata kunci

Jaringan kolaborasi para penulis

24 penulis · 48 tautan kepenulisan bersama · 34 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • National Research and Innovation Agency
  • Telkom University
  • Minia University
  • Egyptian Russian University
  • Benha University
  • Universitas Sumatera Utara
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ahmed H. AliEgyptian Russian University2
Raafat A. El-KammarBenha University2
Hesham F. A. HamedEgyptian Russian University2
Aya HossamBenha University2
Widi AribowoUniversitas Negeri Surabaya2
Feby Agung PamujiInstitut Teknologi Sepuluh Nopember2
Ahmed Mahmoud SolimanMinia University1
Ashraf Nasr EldeenAfiliasi tidak diketahui1
Muhammad Zakiyullah RomdlonyTelkom University1
Herlambang SetiadiUniversitas Airlangga1
Moh. JauhariPoliteknik Negeri Madura1
Mochamad AshariInstitut Teknologi Sepuluh Nopember1
Taurista Perdana SyawitriNational Research and Innovation Agency1
Ganesha Tri ChandrasaInstitut Teknologi Sepuluh Nopember1
Barman TambunanNational Research and Innovation Agency1
Tata SutardiNational Research and Innovation Agency1
Yulianta SiregarUniversitas Sumatera Utara1
Nur Nabila MohamedUniversiti Teknologi MARA1
Muldi YuhendriUniversitas Negeri Padang1
Daniel Julian SinagaUniversitas Sumatera Utara1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Implementation of Adaptive Hysteresis-Band Current Control for Bidirectional H-Bridge DC-DC Converter</dc:title>
	<dc:creator>Riawan, Dedet Candra</dc:creator>
	<dc:creator>Suryoatmojo, Heri</dc:creator>
	<dc:creator>Ravi, Alwy Muhammad</dc:creator>
	<dc:creator>Elbaset, Adel A.</dc:creator>
	<dc:subject xml:lang="en-US">Adaptive Hysteresis-Band</dc:subject>
	<dc:subject xml:lang="en-US">Battery Charging</dc:subject>
	<dc:subject xml:lang="en-US">BiDirectional DC-DC Converter</dc:subject>
	<dc:subject xml:lang="en-US">Electric Vehicle</dc:subject>
	<dc:description xml:lang="en-US">The substantial adoption of electric vehicles (EVs) has the potential to disrupt the power grid due to uncontrolled charging. A promising solution is Vehicle-to-Grid (V2G) technology, which allows EVs to return surplus energy to the grid to maintain reliability. However, a key challenge is developing a bidirectional converter with a rapid response that can also maintain a constant switching frequency to avoid harmonic disturbances. This study introduces an innovative adaptive hysteresis bandwidth current control method for H-bridge converters. This method provides a rapid and precise response to dynamic current and voltage fluctuations while maintaining a constant switching frequency for the MOSFET. The adaptive bandwidth values are mathematically derived from converter principles and implemented via a lookup table in a microcontroller. The simulation results showed a response time of less than 1 millisecond without overshoot. Experimental validation demonstrated the system’s efficacy in maintaining a constant switching frequency under dynamic changes. In charging mode, the average frequency was 14.88 kHz (with a range of 0.79 kHz), and the efficiency was 85.74%, while the fixed hysteresis band has a frequency variation of 14.26 kHz to 20.66 kHz (with a range of 6.37 kHz). In discharge mode, the average frequency was 16.62 kHz (with a range of 0.33 kHz), the efficiency was 77.40%, and the fixed bandwidth is approximately 2.3 kHz on frequency from 15.82 kHz to 18.12 kHz. With adaptive control, the frequency change range is successfully constant with a small range.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2026-01-26</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/27096</dc:identifier>
	<dc:identifier>10.18196/jrc.v6i6.27096</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 6 No. 6 (2025); 3099-3113</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/27096/12183</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Dedet Candra Riawan, Heri Suryoatmojo, Alwy Muhammad Ravi, Adel A. Elbaset</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>