Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

Analysis of Brain Activity in Response to Visual Stimuli Using Electroencephalography: Comparative Study of Neural Network and Machine Learning Classifiers

Journal of Robotics and Control (JRC) · Vol. 7 No. 1 (2026) · hlm. 3405–3421

DOI
10.18196/jrc.v7i1.27216
ISSN
2715-5072, 2715-5056
Terbit
2026-03-13
Penerbit
Universitas Muhammadiyah Yogyakarta
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Electroencephalography (EEG) presents a non-invasive and economical method for examining brain reactions to visual stimuli, demonstrating significant promise for applicable brain–computer interface (BCI) uses. This research examines neural responses triggered by both static and dynamic visual stimuli by utilizing EEG signals collected from 14 healthy subjects with a consumer-grade NeuroSky MindWave device. Fast Fourier Transform (FFT) and Discrete Wavelet Transform (DWT) used as extraction’s feature to capture both frequency and time–frequency-domain information. Four classifiers—Multilayer Perceptron with Backpropagation (MLP-BPNN), Kolmogorov–Arnold Network (KAN), Convolutional Neural Network (CNN), and Support Vector Machine (SVM)—were systematically compared. Performance of each classifier’s method was evaluated through accuracy, precision, recall, F1-score, confusion matrix, and ROC-AUC, with robustness ensured by 5-fold cross-validation. Statistical analysis employed one-way ANOVA to examine performance differences across classifiers. Results revealed that MLP-BPNN combined with DWT features achieved the best overall performance (accuracy = 92.14%, F1-score = 92.14%), while SVM obtained the highest recall (91.86%). KAN achieved competitive results but underperformed in minority class detection, whereas SVM exhibited high training accuracy but indications of overfitting. ANOVA confirmed significant differences among classifiers (p < 0.0001), with MLP-BPNN and SVM outperforming CNN, while no significant difference was observed between MLP-BPNN and KAN. These findings demonstrate the feasibility of reliable EEG-based visual stimulus classification using low-cost consumer devices. Additionally, they emphasize the essential function of statistical validation in evaluating classifiers. Future research should extend to larger, more diverse groups and investigate sophisticated deep learning models for improved generalization in BCI applications.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 40 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Institut Teknologi Sepuluh Nopember
  • Bandung Institute of Technology
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Katherin IndriawatiInstitut Teknologi Sepuluh Nopember6
Nilla Perdana AgustinaInstitut Teknologi Sepuluh Nopember3
Moh Kamalul WafiInstitut Teknologi Sepuluh Nopember2
Kadek Dwi WahyuadnyanaInstitut Teknologi Sepuluh Nopember2
Murry RadityaInstitut Teknologi Sepuluh Nopember2
Hudzaifa Dhiaul AhnafInstitut Teknologi Sepuluh Nopember1
Syahrizal Faried RoosydiInstitut Teknologi Sepuluh Nopember1
Detak Yan PratamaInstitut Teknologi Sepuluh Nopember1
Totok Ruki BiyantoInstitut Teknologi Sepuluh Nopember1
Hilton TnunayBandung Institute of Technology1
Ardyas Nur AufaAfiliasi tidak diketahui1
Atras Yonda FariziInstitut Teknologi Sepuluh Nopember1
Rida Ayu ArfiantiInstitut Teknologi Sepuluh Nopember1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.umy.ac.id/index.php/jrc/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Analysis of Brain Activity in Response to Visual Stimuli Using Electroencephalography: Comparative Study of Neural Network and Machine Learning Classifiers</dc:title>
	<dc:creator>Palwa Sari, Delima</dc:creator>
	<dc:creator>Agus Darwito, Purwadi</dc:creator>
	<dc:creator>Lelono Widjiantoro , Bambang</dc:creator>
	<dc:subject xml:lang="en-US">Electroencephalography</dc:subject>
	<dc:subject xml:lang="en-US">visual stimuli</dc:subject>
	<dc:subject xml:lang="en-US">feature extraction</dc:subject>
	<dc:subject xml:lang="en-US">brain signal classification</dc:subject>
	<dc:description xml:lang="en-US">Electroencephalography (EEG) presents a non-invasive and economical method for examining brain reactions to visual stimuli, demonstrating significant promise for applicable brain–computer interface (BCI) uses. This research examines neural responses triggered by both static and dynamic visual stimuli by utilizing EEG signals collected from 14 healthy subjects with a consumer-grade NeuroSky MindWave device. Fast Fourier Transform (FFT) and Discrete Wavelet Transform (DWT) used as extraction’s feature to capture both frequency and time–frequency-domain information. Four classifiers—Multilayer Perceptron with Backpropagation (MLP-BPNN), Kolmogorov–Arnold Network (KAN), Convolutional Neural Network (CNN), and Support Vector Machine (SVM)—were systematically compared.  Performance of each classifier’s method was evaluated through accuracy, precision, recall, F1-score, confusion matrix, and ROC-AUC, with robustness ensured by 5-fold cross-validation. Statistical analysis employed one-way ANOVA to examine performance differences across classifiers. Results revealed that MLP-BPNN combined with DWT features achieved the best overall performance (accuracy = 92.14%, F1-score = 92.14%), while SVM obtained the highest recall (91.86%). KAN achieved competitive results but underperformed in minority class detection, whereas SVM exhibited high training accuracy but indications of overfitting. ANOVA confirmed significant differences among classifiers (p &amp;lt; 0.0001), with MLP-BPNN and SVM outperforming CNN, while no significant difference was observed between MLP-BPNN and KAN. These findings demonstrate the feasibility of reliable EEG-based visual stimulus classification using low-cost consumer devices. Additionally, they emphasize the essential function of statistical validation in evaluating classifiers. Future research should extend to larger, more diverse groups and investigate sophisticated deep learning models for improved generalization in BCI applications.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Muhammadiyah Yogyakarta</dc:publisher>
	<dc:date>2026-03-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.umy.ac.id/index.php/jrc/article/view/27216</dc:identifier>
	<dc:identifier>10.18196/jrc.v7i1.27216</dc:identifier>
	<dc:source xml:lang="en-US">Journal of Robotics and Control (JRC); Vol. 7 No. 1 (2026); 3405-3421</dc:source>
	<dc:source>2715-5072</dc:source>
	<dc:source>2715-5056</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journal.umy.ac.id/index.php/jrc/article/view/27216/12293</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 Delima Palwa Sari, Purwadi Agus Darwito, Bambang Lelono Widjiantoro </dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>