Melola Discovery

← Melola Discovery

Jurnal SINTA 1

The Analysis of Beam-Column Joint Reinforced with Cross Bars according to SK SNI T-15-1991-03 on Cyclic Loads

Journal of the Civil Engineering Forum · Vol. 8 No. 1 (2021) · hlm. 1–10

DOI
10.22146/jcef.3601
ISSN
2549-5925, 2581-1037
Terbit
2021-12-16
Penerbit
Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada
Bahasa
eng

Abstrak

The primary structural component supporting the other structural loads in a building is the beam-column joint. It is considered a critical area of a building which needs to be accurately designed to ensure energy is dissipated properly during the occurrence of an earthquake. Beam-column joint has the ability to offer a proper structure required to transform cyclic loads in the inelastic region but also has a direct impact on the components connected to it during the occurrence of any failure. This is one of the reasons the beam-column connection needs to be designed carefully. Therefore, this study focused on designing a beam-column joint with reinforcement according to SK SNI T-15-1991 in order to withstand cyclic loads. The test specimen used was observed to have a concrete compressive strength of 19.17 MPa while the dimension of the beam was 120 x 30 x 40 cm and the column was 30 x 30 x 200 cm, having 8Ø13.4 mm bars with 310.03 MPa yield strength (fy) as well as Ø9.8-100 mm stirrup reinforcement with (fy) 374.59 MPa. The test was initiated through the provision of 0.75 mm, 1.5 mm, 3 mm, 6 mm, 12 mm, 24 mm monotonic cyclic loads at the end of the beam up to the moment the specimen cracked. A maximum load of 68.35 kN for the compression and 49.92 kN for the tension was required to attain the cyclic load capacity. The maximum load was attained at 50.98 mm displacement. Furthermore, beam-column with 23.93 mm displacement caused a reduction in capacity. Meanwhile, the load at 24 mm produced the cycle's highest dissipation energy of 13.25 but this can be increased through the addition of stirrups to provide stiffness in the joint. The stiffness value was also observed to have increased after the structural repairs.

Kata kunci

Jaringan kolaborasi para penulis

29 penulis · 60 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Syiah Kuala
  • Jiangsu University
  • Universitas Halu Oleo
  • Jordan University of Science and Technology
  • Universiti Teknologi MARA
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Bahtiar .Afiliasi tidak diketahui2
La Ode Abdul Rajab NadiaAfiliasi tidak diketahui2
Nurlaila AriantoAfiliasi tidak diketahui1
IskandarAfiliasi tidak diketahui1
Ahmad MustafaJordan University of Science and Technology1
Muslim TadjuddahAfiliasi tidak diketahui1
Naslina AliminaAfiliasi tidak diketahui1
Fajeria -Afiliasi tidak diketahui1
Ma’ruf KasimUniversitas Halu Oleo1
. MarliaAfiliasi tidak diketahui1
Jubair Al HadatzAfiliasi tidak diketahui1
Abdul Rahman RahimUniversiti Teknologi MARA1
Andi Irwan NurUniversitas Halu Oleo1
Hardianto SasmitoAfiliasi tidak diketahui1
La AnadiAfiliasi tidak diketahui1
. SamidaAfiliasi tidak diketahui1
Mustafa SabriUniversitas Syiah Kuala1
Irma HidayatiAfiliasi tidak diketahui1
YusrizalAfiliasi tidak diketahui1
, MarlizaAfiliasi tidak diketahui1
Yahya NjieJiangsu University1
Weidong WangJiangsu University1
Liu LinJiangsu University1
. IswandiAfiliasi tidak diketahui1
Gratischa VHL MaaniAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ugm.ac.id/v3/jcef/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Analysis of Beam-Column Joint Reinforced with Cross Bars according to SK SNI T-15-1991-03 on Cyclic Loads</dc:title>
	<dc:creator>Araby, Zardan </dc:creator>
	<dc:creator>Samsul Rizal</dc:creator>
	<dc:creator>Abdullah</dc:creator>
	<dc:creator>Mochammad Afifuddin</dc:creator>
	<dc:subject xml:lang="en-US">Beam-Column Joint</dc:subject>
	<dc:subject xml:lang="en-US">Cyclic Load</dc:subject>
	<dc:subject xml:lang="en-US">Ductility;</dc:subject>
	<dc:subject xml:lang="en-US">Monotonic Loading</dc:subject>
	<dc:subject xml:lang="en-US">Building Structure</dc:subject>
	<dc:description xml:lang="en-US">The primary structural component supporting the other structural loads in a building is the beam-column joint. It is considered a critical area of a building which needs to be accurately designed to ensure energy is dissipated properly during the occurrence of an earthquake. Beam-column joint has the ability to offer a proper structure required to transform cyclic loads in the inelastic region but also has a direct impact on the components connected to it during the occurrence of any failure. This is one of the reasons the beam-column connection needs to be designed carefully. Therefore, this study focused on designing a beam-column joint with reinforcement according to SK SNI T-15-1991 in order to withstand cyclic loads. The test specimen used was observed to have a concrete compressive strength of 19.17 MPa while the dimension of the beam was 120 x 30 x 40 cm and the column was 30 x 30 x 200 cm, having 8Ø13.4 mm bars with 310.03 MPa yield strength (fy) as well as Ø9.8-100 mm stirrup reinforcement with (fy) 374.59 MPa. The test was initiated through the provision of 0.75 mm, 1.5 mm, 3 mm, 6&amp;nbsp;mm, 12 mm, 24 mm monotonic cyclic loads at the end of the beam up to the moment the specimen cracked. A maximum load of 68.35 kN for the compression and 49.92 kN for the tension was required to attain the cyclic load capacity. The maximum load was attained at 50.98 mm displacement. Furthermore, beam-column with 23.93 mm displacement caused a reduction in capacity. Meanwhile, the load at 24 mm produced the cycle's highest dissipation energy of 13.25 but this can be increased through the addition of stirrups to provide stiffness in the joint. The stiffness value was also observed to have increased after the structural repairs.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada</dc:publisher>
	<dc:date>2021-12-16</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ugm.ac.id/v3/JCEF/article/view/3601</dc:identifier>
	<dc:identifier>10.22146/jcef.3601</dc:identifier>
	<dc:source xml:lang="en-US">Journal of the Civil Engineering Forum; Vol. 8 No. 1 (January 2022); 1-10</dc:source>
	<dc:source>2549-5925</dc:source>
	<dc:source>2581-1037</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ugm.ac.id/v3/JCEF/article/view/3601/1265</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 The Author(s)</dc:rights>
</oai_dc:dc>