Melola Discovery

← Melola Discovery

Jurnal SINTA 1

The Mandatory 4 Years Desludging Frequency of Underground Septic Tanks in Residential Areas: A Case Study in Sibu Sarawak, East Malaysia

Journal of the Civil Engineering Forum · Vol. 8 No. 2 (2022) · hlm. 147–156

DOI
10.22146/jcef.3812
ISSN
2549-5925, 2581-1037
Terbit
2022-05-25
Penerbit
Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada
Bahasa
eng

Abstrak

Underground septic tanks are the most common and conventional primary black water treatment adopted by local households in Sarawak. To ensure its usefulness, periodic mandatory desludging or emptying of the various types of rateable holdings was enforced from 1998. The current mandatory desludging frequency is 4 years for residential households, although its effectiveness is still not clear, substantial annual finance and subsidies are being allocated by the Sarawak State Government. In this study, the underground septic tanks in Sibu located in residential areas in Sarawak, East Malaysia, were evaluated quantitatively based on the measured faecal sludge with a known retention time in respect to the regulated desludging frequency. Furthermore, various problems were encountered during the initial measurement carried out by sludge judge which typically used by the wastewater treatment and chemical plants. A modified PVC pipe was proposed to overcome these observed problems. This has greatly improved the measurement time and substantially reduced unwanted impediments for the contractor during desludging. The back analysis results showed that the recommended desludging frequency based on the ratio of total sludge and scum to the effective working volume in 30% and 50% thresholds for residential areas were 3.82 and 6.36 years, respectively. Furthermore, it was discovered that there was a potential to adjust the existing mandatory 4 years desludging frequency to a longer period for cost-effective consideration. This study is strictly on the physical quantity measurement of sludge and scum volumes for the known retention times. The complex influences of microbiological activities, micro-environmental factors and sizes or geometries of septic tanks for faecal sludge production were not considered.

Kata kunci

Jaringan kolaborasi para penulis

10 penulis · 27 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • University of Technology Sarawak
  • INTI International University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Yong Tat LimUniversity of Technology Sarawak6
Ling Jen HuaUniversity of Technology Sarawak2
Chong Chun HouUniversity of Technology Sarawak2
Mazizah Ezdiani MohamadUniversity of Technology Sarawak2
Euniza Anak JusliINTI International University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ugm.ac.id/v3/jcef/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Mandatory 4 Years Desludging Frequency of Underground Septic Tanks in Residential Areas: A Case Study in Sibu Sarawak, East Malaysia</dc:title>
	<dc:creator>Wen Kam Leong</dc:creator>
	<dc:creator>Alex Lung Keat Ngo</dc:creator>
	<dc:creator>Alvin Choon Hsien Wong </dc:creator>
	<dc:creator> Jen Hua Ling</dc:creator>
	<dc:creator>How Teck Sia</dc:creator>
	<dc:subject xml:lang="en-US">Underground septic tank</dc:subject>
	<dc:subject xml:lang="en-US">Desludging frequency</dc:subject>
	<dc:subject xml:lang="en-US">Faecal sludge</dc:subject>
	<dc:subject xml:lang="en-US">Sludge judge</dc:subject>
	<dc:subject xml:lang="en-US">Modified PVC pipe</dc:subject>
	<dc:description xml:lang="en-US">&amp;nbsp;Underground septic tanks are the most common and conventional primary black water treatment adopted by local households in Sarawak. To ensure its usefulness, periodic mandatory desludging or emptying of the various types of rateable holdings was enforced from 1998. The current mandatory desludging frequency is 4 years for residential households, although its effectiveness is still not clear, substantial annual finance and subsidies are being allocated by the Sarawak State Government. In this study, the underground septic tanks in Sibu located in residential areas in Sarawak, East Malaysia, were evaluated quantitatively based on the measured faecal sludge with a known retention time in respect to the regulated desludging frequency. Furthermore, various problems were encountered during the initial measurement carried out by sludge judge which typically used by the wastewater treatment and chemical plants. A modified PVC pipe was proposed to overcome these observed problems. This has greatly improved the measurement time and substantially reduced unwanted impediments for the contractor during desludging. The back analysis results showed that the recommended desludging frequency based on the ratio of total sludge and scum to the effective working volume in 30% and 50% thresholds for residential areas were 3.82 and 6.36 years, respectively. Furthermore, it was discovered that there was a potential to adjust the existing mandatory 4 years desludging frequency to a longer period for cost-effective consideration. This study is strictly on the physical quantity measurement of sludge and scum volumes for the known retention times. The complex influences of microbiological activities, micro-environmental factors and sizes or geometries of septic tanks for faecal sludge production were not considered.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada</dc:publisher>
	<dc:date>2022-05-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ugm.ac.id/v3/JCEF/article/view/3812</dc:identifier>
	<dc:identifier>10.22146/jcef.3812</dc:identifier>
	<dc:source xml:lang="en-US">Journal of the Civil Engineering Forum; Vol. 8 No. 2 (May 2022); 147-156</dc:source>
	<dc:source>2549-5925</dc:source>
	<dc:source>2581-1037</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ugm.ac.id/v3/JCEF/article/view/3812/1635</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2022 The Author(s)</dc:rights>
</oai_dc:dc>