Melola Discovery

← Melola Discovery

Jurnal SINTA 1

The Analysis of Groundwater Quality for Drinking Purposes: A Case Study of Universitas Muhammadiyah Makassar Area

Journal of the Civil Engineering Forum · Vol. 9 No. 1 (2022) · hlm. 27–36

DOI
10.22146/jcef.4678
ISSN
2549-5925, 2581-1037
Terbit
2022-11-30
Penerbit
Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada
Bahasa
eng

Abstrak

The use of groundwater for drinking purposes is increasing along with population growth and the wider range of human activities that require water. Groundwater is used more often because it is more accessible than surface water. The quality of groundwater suitable for consumption as drinking water must pass physical, chemical and biological parameter tests. This study aims to analyze the comparison of groundwater quality at depths of 30 and 100 meters in the area of the Universitas Muhammadiyah Makassar and determine its suitability as drinking water based on physical, chemical, and biological parameters. This research is an experimental study with water sampling collected at two different locations: 30-meter and 100-meter depth wells. In each well, sampling was carried out three times so that there were six total water samples analyzed in total. Data collection was carried out by observation and laboratory tests. Observations were made by looking directly at groundwater conditions to measure parameters such as odor, color, temperature, and pH, while other parameters were tested in the laboratory. The data analysis results showed differences in the values of the physical, chemical, and biological parameters of groundwater taken at a depth of 30 meters and 100 meters. However, the two samples are still within the standard’s allowable range of values. This study concluded that groundwater at a depth of 100 meters in the Universitas Muhammadiyah Makassar area has better water quality than groundwater at a depth of 30 meters. Therefore, if groundwater at a depth of 30 meters is to be used as drinking water with good quality, it must undergo specific treatment.

Kata kunci

Jaringan kolaborasi para penulis

19 penulis · 39 tautan kepenulisan bersama · 16 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Muhammadiyah University of Makassar
  • State University of Makassar
  • Institut Teknologi Sepuluh Nopember
  • Seoul National University
  • Universitas Jambi
  • National Research and Innovation Agency
  • Ewha Womans University
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Jinwoong SongSeoul National University2
Subaer -Afiliasi tidak diketahui1
Ina SafitriState University of Makassar1
Halimah HusainState University of Makassar1
Muhammad Al MuttaqiiNational Research and Innovation Agency1
Yustia Wulandari MirzayantiAfiliasi tidak diketahui1
Lenny MarlindaUniversitas Jambi1
Abdul AzizInstitut Teknologi Sepuluh Nopember1
Achmad RoesyadiInstitut Teknologi Sepuluh Nopember1
Danawati Hari PrajitnoInstitut Teknologi Sepuluh Nopember1
Nurazmi NurazmiMuhammadiyah University of Makassar1
Tri Hastiti FiskawarniMuhammadiyah University of Makassar1
Jisun ParkEwha Womans University1
Khaeruddin KhaeruddinState University of Makassar1
Sudarmin SudarminState University of Semarang1
Salmia SalmiaMuhammadiyah University of Makassar1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ugm.ac.id/v3/jcef/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The Analysis of Groundwater Quality for Drinking Purposes: A Case Study of Universitas Muhammadiyah Makassar Area</dc:title>
	<dc:creator>Nanda, Abd Rakhim</dc:creator>
	<dc:creator>Rahmi</dc:creator>
	<dc:creator>Bancong, Hartono</dc:creator>
	<dc:subject xml:lang="en-US">Drinking water</dc:subject>
	<dc:subject xml:lang="en-US">Groundwater</dc:subject>
	<dc:subject xml:lang="en-US">Quality control</dc:subject>
	<dc:subject xml:lang="en-US">Water quality</dc:subject>
	<dc:subject xml:lang="en-US">Well water</dc:subject>
	<dc:description xml:lang="en-US">The use of groundwater for drinking purposes is increasing along with population growth and the wider range of human activities that require water. Groundwater is used more often because it is more accessible than surface water. The quality of groundwater suitable for consumption as drinking water must pass physical, chemical and biological parameter tests. This study aims to analyze the comparison of groundwater quality at depths of 30 and 100 meters in the area of the Universitas Muhammadiyah Makassar and determine its suitability as drinking water based on physical, chemical, and biological parameters. This research is an experimental study with water sampling collected at two different locations: 30-meter and 100-meter depth wells. In each well, sampling was carried out three times so that there were six total water samples analyzed in total. Data collection was carried out by observation and laboratory tests. Observations were made by looking directly at groundwater conditions to measure parameters such as odor, color, temperature, and pH, while other parameters were tested in the laboratory. The data analysis results showed differences in the values of the physical, chemical, and biological parameters of groundwater taken at a depth of 30 meters and 100 meters. However, the two samples are still within the standard’s allowable range of values. This study concluded that groundwater at a depth of 100 meters in the Universitas Muhammadiyah Makassar area has better water quality than groundwater at a depth of 30 meters. Therefore, if groundwater at a depth of 30 meters is to be used as drinking water with good quality, it must undergo specific treatment.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada</dc:publisher>
	<dc:date>2022-11-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ugm.ac.id/v3/JCEF/article/view/4678</dc:identifier>
	<dc:identifier>10.22146/jcef.4678</dc:identifier>
	<dc:source xml:lang="en-US">Journal of the Civil Engineering Forum; Vol. 9 No. 1 (January 2023); 27-36</dc:source>
	<dc:source>2549-5925</dc:source>
	<dc:source>2581-1037</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ugm.ac.id/v3/JCEF/article/view/4678/2117</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s)</dc:rights>
</oai_dc:dc>