Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Wastewater Characterization and pH Neutralizing Effect of Adsorbents: A Case Study of Concrete Wash Wastewater from a Ready-Mix Plant

Journal of the Civil Engineering Forum · Vol. 9 No. 2 (2023) · hlm. 209–216

DOI
10.22146/jcef.6622
ISSN
2549-5925, 2581-1037
Terbit
2023-05-12
Penerbit
Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada
Bahasa
eng

Abstrak

This study aims to characterize washed concrete wastewater and examine the effectiveness of three different adsorbents in reducing its high alkalinity and metal contents. It is important to note that proper treatment is essential before discharging wastewater into water bodies to prevent any negative impact on the environment. Therefore, in this study, an adsorption scenario was conducted to obtain optimum treatment for washed concrete wastewater. The objectives of this study are as follows (1) to determine the typical characteristics of washed concrete wastewater based on the parameters outlined in the Regulation of the Ministry of Environment of Indonesia No 5 of 2014 and (2) to assess the performance of different adsorbents. Three wastewater samples were obtained from a ready-mix plant and then tested in the laboratory. The initial test was conducted to identify influent characteristics, and from this test, it was found that only the pH level exceeded the specified standard. Following this, the study then assessed the ability of three adsorbents to reduce the pH level in washed concrete wastewater using the batch test in Duplo. The pH level was measured at 0.25, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, and 24 hours. The three adsorbents tested were activated carbon, clay brick, and dried domestic sewage sludge. The result shows that dried domestic sewage sludge was the most effective at reducing alkaline wastewater due to its acidic pH. Therefore, it has the potential to replace other commercial adsorbents and reduce the problem of sludge disposal. Further research on this material is recommended, such as evaluating its performance in a more solid form, such as brick, and assessing its contamination potential.

Kata kunci

Jaringan kolaborasi para penulis

5 penulis · 7 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Syafira Bunga Az ZahraUniversitas Gadjah Mada1
Budi KamulyanUniversitas Gadjah Mada1
Hendra DewataUniversitas Gadjah Mada1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ugm.ac.id/v3/jcef/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Wastewater Characterization and pH Neutralizing Effect of Adsorbents: A Case Study of Concrete Wash Wastewater from a Ready-Mix Plant</dc:title>
	<dc:creator>Adhin Harum Wulaningtyas</dc:creator>
	<dc:creator>Ni Nyoman Nepi Marleni</dc:creator>
	<dc:subject xml:lang="en-US">Activated Carbon</dc:subject>
	<dc:subject xml:lang="en-US">Sewage Sludge</dc:subject>
	<dc:subject xml:lang="en-US">Clay Brick</dc:subject>
	<dc:subject xml:lang="en-US">Alkaline Wastewater</dc:subject>
	<dc:subject xml:lang="en-US">Adsorbent</dc:subject>
	<dc:description xml:lang="en-US">This study aims to characterize washed concrete wastewater and examine the effectiveness of three different adsorbents in reducing its high alkalinity and metal contents. It is important to note that proper treatment is essential before discharging wastewater into water bodies to prevent any negative impact on the environment. Therefore, in this study, an adsorption scenario was conducted to obtain optimum treatment for washed concrete wastewater. The objectives of this study are as follows (1) to determine the typical characteristics of washed concrete wastewater based on the parameters outlined in the Regulation of the Ministry of Environment of Indonesia No 5 of 2014 and (2) to assess the performance of different adsorbents. Three wastewater samples were obtained from a ready-mix plant and then tested in the laboratory. The initial test was conducted to identify influent characteristics, and from this test, it was found that only the pH level exceeded the specified standard. Following this, the study then assessed the ability of three adsorbents to reduce the pH level in washed concrete wastewater using the batch test in Duplo. The pH level was measured at 0.25, 0.5, 1, 2, 3, 4, 5, 6, 7, 8, and 24 hours. The three adsorbents tested were activated carbon, clay brick, and dried domestic sewage sludge. The result shows that dried domestic sewage sludge was the most effective at reducing alkaline wastewater due to its acidic pH. Therefore, it has the potential to replace other commercial adsorbents and reduce the problem of sludge disposal. Further research on this material is recommended, such as evaluating its performance in a more solid form, such as brick, and assessing its contamination potential.
&amp;nbsp;</dc:description>
	<dc:publisher xml:lang="en-US">Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada</dc:publisher>
	<dc:date>2023-05-12</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ugm.ac.id/v3/JCEF/article/view/6622</dc:identifier>
	<dc:identifier>10.22146/jcef.6622</dc:identifier>
	<dc:source xml:lang="en-US">Journal of the Civil Engineering Forum; Vol. 9 No. 2 (May 2023); 209-216</dc:source>
	<dc:source>2549-5925</dc:source>
	<dc:source>2581-1037</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ugm.ac.id/v3/JCEF/article/view/6622/2545</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2023 The Author(s)</dc:rights>
</oai_dc:dc>