Melola Discovery

← Melola Discovery

Jurnal SINTA 2

Development of a Two-Channel Simultaneous Photoplethysmography Recording System

Journal of ICT Research and Applications (JICTRA) · Vol. 6 No. 2 (2013) · hlm. 171–182

DOI
10.5614/itbj.ict.2012.6.2.5
ISSN
2338-5499, 2337-5787
Terbit
2013-09-13
Penerbit
DRI - ITB
Bahasa
eng

Abstrak

Multi-site photoplethysmograph (PPG) recording enables researchers to study the vascular and hemodynamic properties of human subjects. Currently, there is no commercial system available in the market to perform either one channel or multi-channel PPG recording. PPG is an optoelectronic technique that measures changes in blood volume associated with cardiac contraction. The measurements can be obtained from fingertips, ear lobes and toes due to their low absorption and high degree of vasculature. The main objective of this project is to develop a two-channel simultaneous PPG recording system to acquire PPG signals from two different physiological sites using a Nellcor equivalent PPG probe. MATLAB software was used during the development phase to ensure rapid prototyping. The experiment results show that there was no inter -channel delay in the developed two-channel PPG system. Our preliminary results show that the delays between the left and the right arm were from 4 to 12 ms in three healthy random subjects. The system is portable, powered by universal serial bus (USB) and allows the user to do the PPG data acquisition in a clinical setting.

Jaringan kolaborasi para penulis

3 penulis · 3 tautan kepenulisan bersama

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • National University of Malaysia
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jictra/oai, pertama di-harvest 26 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Development of a Two-Channel Simultaneous Photoplethysmography Recording System</dc:title>
	<dc:creator>Chong, Kim Soon</dc:creator>
	<dc:creator>Gan, Kok Beng</dc:creator>
	<dc:creator>Mohd. Alauddin, Mohd. Ali</dc:creator>
	<dc:description xml:lang="en-US">Multi-site photoplethysmograph  (PPG) recording enables researchers to study the vascular and hemodynamic  properties of human subjects. Currently, there  is  no  commercial  system  available  in  the  market  to  perform  either  one channel or multi-channel PPG recording. PPG is an optoelectronic technique that measures  changes  in  blood  volume  associated  with  cardiac  contraction.  The measurements  can  be  obtained  from  fingertips,  ear  lobes  and toes  due  to  their low absorption and high degree of vasculature. The main objective of this project is to develop a two-channel simultaneous PPG recording system to acquire PPG signals  from  two  different  physiological  sites  using  a  Nellcor  equivalent  PPG probe.  MATLAB  software  was  used  during  the  development  phase  to  ensure rapid prototyping. The experiment results show that there was no inter -channel delay in the developed two-channel PPG system. Our preliminary results show that the delays between the left and the right arm were from 4 to 12 ms in three healthy random subjects. The system is portable, powered by universal serial bus (USB) and allows the user to do the PPG data acquisition in a clinical setting.</dc:description>
	<dc:publisher xml:lang="en-US">DRI - ITB</dc:publisher>
	<dc:date>2013-09-13</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jictra/article/view/227</dc:identifier>
	<dc:identifier>10.5614/itbj.ict.2012.6.2.5</dc:identifier>
	<dc:source xml:lang="en-US">Journal of ICT Research and Applications; Vol. 6 No. 2 (2012); 171-182</dc:source>
	<dc:source>2338-5499</dc:source>
	<dc:source>2337-5787</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jictra/article/view/227/221</dc:relation>
</oai_dc:dc>