Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Seismic and Tsunamis Vulnerability Assessment of the Shelter School Building Structure with and without Retrofitting

Journal of the Civil Engineering Forum · Vol. 11 No. 1 (2025) · hlm. 89–100

DOI
10.22146/jcef.13432
ISSN
2549-5925, 2581-1037
Terbit
2025-01-17
Penerbit
Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada
Bahasa
eng

Abstrak

Understanding the vulnerability of school shelters to tsunamis is crucial for developing effective mitigation strategies and increasing the resilience of coastal communities in the education sector. SDN 02 Sasak Ranah Pasisia, an elementary school in West Pasaman Regency, West Sumatera, Indonesia, had a shelter building constructed in 2010. However, the construction remains incomplete. A structural assessment using current Indonesian building codes and vulnerability analysis is necessary to proceed with construction and ensure the building’s strength against the working loads. Thestructural assessment revealed that several columns could not support the working load, necessitating local retrofitting. In this study, the retrofitting of the building was designed using concrete jacketing. Furthermore, structural fragility curves of the school building were developed before and after retrofitting against earthquake and tsunami loads. The seismic fragility curve was determined from the maximum displacement of the building for varied earthquake acceleration, using nonlinear time history dynamic response analysis scaled using the incremental dynamic analysis method and damage limits defined by ATC-40, characterized by Hazus. Meanwhile, the tsunami fragility curve was determined from the maximum displacement due to tsunami load for each variation of tsunami inundation depth. The vulnerability analysis results indicated that retrofitting the school building with concrete jacketing reduces the probability of building damage due to earthquake loads by 18% at the level of complete damage at a PGA of 0.520 g (based on the Indonesian Seismic Map). Similarly, it reduced the probability of building damage due to tsunami loads by 20%, at the level of complete damage corresponding to a tsunami wave height of 5.00 m for West Pasaman, Indonesia.

Kata kunci

Jaringan kolaborasi para penulis

16 penulis · 51 tautan kepenulisan bersama · 17 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Tadulako University
  • Toyohashi University of Technology
  • Andalas University
  • Universitas Widya Nusantara
  • Universitas Pembangunan Nasional Veteran Yogyakarta
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Adhar ArifuddinTadulako University2
A Fahira NurUniversitas Widya Nusantara2
Ratna DeviTadulako University2
Ni Wayan SridaniTadulako University2
Fahinu .Afiliasi tidak diketahui1
Iva RachmawatiUniversitas Pembangunan Nasional Veteran Yogyakarta1
Muh SabirAfiliasi tidak diketahui1
Abd RahmanTadulako University1
SukrangTadulako University1
Mursyidah KhairiyahTadulako University1
Abd RahmanTadulako University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ugm.ac.id/v3/jcef/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Seismic and Tsunamis Vulnerability Assessment of the Shelter School Building Structure with and without Retrofitting</dc:title>
	<dc:creator>Fauzan</dc:creator>
	<dc:creator>Zev Al Jauhari</dc:creator>
	<dc:creator>Geby Aryo Agista</dc:creator>
	<dc:creator>Yokota, Atsushi</dc:creator>
	<dc:creator>Masharya Eko Putra</dc:creator>
	<dc:subject xml:lang="en-US">Shelter School Building</dc:subject>
	<dc:subject xml:lang="en-US">Seismic</dc:subject>
	<dc:subject xml:lang="en-US">Tsunami</dc:subject>
	<dc:subject xml:lang="en-US">Concrete Jacketing</dc:subject>
	<dc:subject xml:lang="en-US">Fragility Curve</dc:subject>
	<dc:description xml:lang="en-US">Understanding the vulnerability of school shelters to tsunamis is crucial for developing effective mitigation strategies and increasing the resilience of coastal communities in the education sector. SDN 02 Sasak Ranah Pasisia, an elementary school in West Pasaman Regency, West Sumatera, Indonesia, had a shelter building constructed in 2010. However, the construction remains incomplete. A structural assessment using current Indonesian building codes and vulnerability analysis is necessary to proceed with construction and ensure the building’s strength against the working loads. Thestructural assessment revealed that several columns could not support the working load, necessitating local retrofitting. In this study, the retrofitting of the building was designed using concrete jacketing. Furthermore, structural fragility curves of the school building were developed before and after retrofitting against earthquake and tsunami loads. The seismic fragility curve was determined from the maximum displacement of the building for varied earthquake acceleration, using nonlinear time history dynamic response analysis scaled using the incremental dynamic analysis method and damage limits defined by ATC-40, characterized by Hazus. Meanwhile, the tsunami fragility curve was determined from the maximum displacement due to tsunami load for each variation of tsunami inundation depth. The vulnerability analysis results indicated that retrofitting the school building with concrete jacketing reduces the probability of building damage due to earthquake loads by 18% at the level of complete damage at a PGA of 0.520 g (based on the Indonesian Seismic Map). Similarly, it reduced the probability of building damage due to tsunami loads by 20%, at the level of complete damage corresponding to a tsunami wave height of 5.00 m for West Pasaman, Indonesia.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada</dc:publisher>
	<dc:date>2025-01-17</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ugm.ac.id/v3/JCEF/article/view/13432</dc:identifier>
	<dc:identifier>10.22146/jcef.13432</dc:identifier>
	<dc:source xml:lang="en-US">Journal of the Civil Engineering Forum; Vol. 11 No. 1 (January 2025); 89-100</dc:source>
	<dc:source>2549-5925</dc:source>
	<dc:source>2581-1037</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ugm.ac.id/v3/JCEF/article/view/13432/5386</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2025 The Author(s)</dc:rights>
</oai_dc:dc>