Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Real-time Application and Statistical Evaluation of Reservoir Operating Rules Under Inflow Uncertainty in Monte Carlo Simulations

Journal of the Civil Engineering Forum · Vol. 12 No. 3 (2026) · hlm. 305–322

DOI
10.22146/jcef.24906
ISSN
2549-5925, 2581-1037
Terbit
2026-06-18
Penerbit
Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada
Bahasa
eng

Abstrak

Reservoir Operating Rules (ROR) have been well-known in Indonesia as guidelines for reservoir operation that comprise the release rules and rule curves derived from the dependable inflow time series in dry, normal, and wet conditions. However, likely because of the incoherence of the original application concept of ROR, the real performance of ROR in reservoir operation has so far remained unclear. This paper proposes a practical application concept of ROR and evaluates the performance of its implementation for annual storage conservation and periodic demand satisfaction under inflow uncertainty in the integrated system of Segawe Regulating Weir, Wonorejo Multipurpose Dam, and Tiudan Regulating Dam. The release rules for the three hydraulic structures were integrated into a unified “Wonorejo ROR”throughoptimization of water allocation over 36 ten-day operational periods. The performance of the application of Wonorejo ROR was evaluated based on several operational success and failure events in Monte Carlo simulations, for which 1,000 years of unique and independent synthetic inflow time series were generated from the Thomas–Fiering model. Under the application concept of ROR, the release decisions for the three hydraulic structures were made in real-time solely based on the actual water level of Wonorejo Reservoir and the rule curves of Wonorejo ROR. For comparative purposes, the Monte Carlo simulations were carried out to evaluate two alternatives of Wonorejo ROR, namely ROR-D65 and ROR-D80, which had different dry inflow exceedance probabilities. Based on the specified events in the Monte Carlo simulations, ROR-D65 and ROR-D80 resulted in reliabilities of 76.4% and 81.3% for annual storage conservation, and the lowest reliabilities of 73.9% and 52.4% for periodic demand satisfaction, respectively. In addition, other reservoir operational performancesandacomprehensive interpretation oftheproposed applicationconcept of ROR arepresented in this paper.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 14 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Gadjah Mada
  • Politeknik Negeri Bali
  • University of Bangka Belitung
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kurniawan Putra SantosoUniversitas Gadjah Mada2
Fransisca Natania Karina RediastiUniversitas Gadjah Mada1
Bambang TriatmodjoUniversitas Gadjah Mada1
I Made Marsa ArsanaPoliteknik Negeri Bali1
Ni Luh Linda MuliasihPoliteknik Negeri Bali1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://jurnal.ugm.ac.id/v3/jcef/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Real-time Application and Statistical Evaluation of Reservoir Operating Rules Under Inflow Uncertainty in Monte Carlo Simulations</dc:title>
	<dc:creator>Mujiburrakhman, Muhammad</dc:creator>
	<dc:creator>Jayadi, Rachmad</dc:creator>
	<dc:creator>Istiarto</dc:creator>
	<dc:creator>Nurdianyoto, Indra</dc:creator>
	<dc:subject xml:lang="en-US">Inflow uncertainty</dc:subject>
	<dc:subject xml:lang="en-US">Monte Carlo simulations</dc:subject>
	<dc:subject xml:lang="en-US">Real-time application of Reservoir Operating Rules</dc:subject>
	<dc:subject xml:lang="en-US">Reservoir operational performance</dc:subject>
	<dc:subject xml:lang="en-US">Thomas-Fiering model</dc:subject>
	<dc:description xml:lang="en-US">Reservoir Operating Rules (ROR) have been well-known in Indonesia as guidelines for reservoir operation that comprise the release rules and rule curves derived from the dependable inflow time series in dry, normal, and wet conditions. However, likely because of the incoherence of the original application concept of ROR, the real performance of ROR in reservoir operation has so far remained unclear. This paper proposes a practical application concept of ROR and evaluates the performance of its implementation for annual storage conservation and periodic demand satisfaction under inflow uncertainty in the integrated system of Segawe Regulating Weir, Wonorejo Multipurpose Dam, and Tiudan Regulating Dam. The release rules for the three hydraulic structures were integrated into a unified “Wonorejo ROR”throughoptimization of water allocation over 36 ten-day operational periods. The performance of the application of Wonorejo ROR was evaluated based on several operational success and failure events in Monte Carlo simulations, for which 1,000 years of unique and independent synthetic inflow time series were generated from the Thomas–Fiering model. Under the application concept of ROR, the release decisions for the three hydraulic structures were made in real-time solely based on the actual water level of Wonorejo Reservoir and the rule curves of Wonorejo ROR. For comparative purposes, the Monte Carlo simulations were carried out to evaluate two alternatives of Wonorejo ROR, namely ROR-D65 and ROR-D80, which had different dry inflow exceedance probabilities. Based on the specified events in the Monte Carlo simulations, ROR-D65 and ROR-D80 resulted in reliabilities of 76.4% and 81.3% for annual storage conservation, and the lowest reliabilities of 73.9% and 52.4% for periodic demand satisfaction, respectively. In addition, other reservoir operational performancesandacomprehensive interpretation oftheproposed applicationconcept of ROR arepresented in this paper.</dc:description>
	<dc:publisher xml:lang="en-US">Department of Civil and Environmental Engineering, Faculty of Engineering, Universitas Gadjah Mada</dc:publisher>
	<dc:date>2026-06-18</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jurnal.ugm.ac.id/v3/JCEF/article/view/24906</dc:identifier>
	<dc:identifier>10.22146/jcef.24906</dc:identifier>
	<dc:source xml:lang="en-US">Journal of the Civil Engineering Forum; Vol. 12 No. 3 (September 2026); 305-322</dc:source>
	<dc:source>2549-5925</dc:source>
	<dc:source>2581-1037</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jurnal.ugm.ac.id/v3/JCEF/article/view/24906/7204</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2026 The Author(s)</dc:rights>
</oai_dc:dc>