Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Differences in The Number of Germs in The Insertion Area of Central Venous Catheter (CVC) Done by Polyurethane Transparent and Plaster Gauze Dressing

Jurnal Keperawatan Padjadjaran · Vol. 6 No. 3 (2018)

DOI
10.24198/jkp.v6i3.324
ISSN
2442-7276, 2338-5324
Terbit
2018-12-25
Penerbit
Faculty of Nursing Universitas Padjadjaran
Bahasa
eng

Abstrak

A central venous catheter is a catheter that is placed directly on a large vein in the body and its tip lies in one of the central veins that is often used on critical care patients. Colonization of bacteria (germ) around the insertion area of the CVC is an area that is very likely to cause infection even though it has been closed by dressing. The factor that should always be considered is that the state of moisture retention occurs beneath the dressing. Moisture will cause an increase in colonization of the insertion area and increase the risk of catheter-related infection. As is known the humidity level of Indonesia with other countries is higher and the results of positive swabs in the insertion area are associated with Percutaneous Central Venous Catheter (PCVC) colonization and Catheter-related Sepsis (CRS). Transparent polyurethane and plaster gauze are two types of dressings that are different and often used. The transparent polyurethane is widely used in invasive procedures, there are still many medical staff who use plaster gauze dressings. The purpose of this study is to determine the difference in the number of germs in the CVC insertion area that are dressed using transparent polyurethane and plaster gauze. The design of this study is a quasi-experimental pretest-posttest control group with positive sampling. The number of samples is 12 for the intervention group and 11 for the control group. The intervention group performed transparent polyurethane dressings and a control group with plaster gauze. Calculation in the number of germs is with the cup count method. Wilcoxon and Mann-Whitney tests are for te data analysis. Based on the results of the study, it can be concluded that there is no difference in the number of CVC insertion germs between the use of dressings transparent polyurethane and plaster gauze so that both types of dressings can be used for CVC dressings in critical patient care settings.Â

Kata kunci

Jaringan kolaborasi para penulis

25 penulis · 54 tautan kepenulisan bersama · 8 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Padjadjaran University
  • Dr. Hasan Sadikin General Hospital
  • Institut Teknologi dan Kesehatan Ika Bina
  • Sunan Gunung Djati State Islamic University Bandung
  • Universitas Santo Borromeus
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ayu PrawestiPadjadjaran University3
Yanny Trisyani WPadjadjaran University3
Aan NuraeniPadjadjaran University2
Ristina MirwantiPadjadjaran University2
Ermiati ErmiatiPadjadjaran University2
Anastasia AnnaPadjadjaran University2
S SuryaniPadjadjaran University1
Weni Widya ShariAfiliasi tidak diketahui1
Hendy LesmanaInstitut Teknologi dan Kesehatan Ika Bina1
Iyus YosepPadjadjaran University1
Kusman IbrahimPadjadjaran University1
Suryani SuryaniPadjadjaran University1
Yani AF BastianAfiliasi tidak diketahui1
Anita SetyawatiPadjadjaran University1
Sari FatimahPadjadjaran University1
Lidya LidyaPadjadjaran University1
Yayan MulyanaSunan Gunung Djati State Islamic University Bandung1
Urip RahayuPadjadjaran University1
Restuning WidiasihPadjadjaran University1
Titin SutiniPadjadjaran University1
M. Hanif Prasetya 'AdhiPadjadjaran University1
Albertus Budi AriantoUniversitas Santo Borromeus1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://jkp.fkep.unpad.ac.id/index.php/jkp/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Differences in The Number of Germs in The Insertion Area of Central Venous Catheter (CVC) Done by Polyurethane Transparent and Plaster Gauze Dressing</dc:title>
	<dc:creator>Fathonah, Septiana</dc:creator>
	<dc:creator>Murni, Tri Wahyu</dc:creator>
	<dc:creator>Emaliyawati, Etika</dc:creator>
	<dc:subject xml:lang="id-ID">CVC insertion area</dc:subject>
	<dc:subject xml:lang="id-ID">dressing</dc:subject>
	<dc:subject xml:lang="id-ID">number of germs</dc:subject>
	<dc:subject xml:lang="id-ID">plaster gauze and transparent polyurethane.</dc:subject>
	<dc:subject xml:lang="id-ID">nursing</dc:subject>
	<dc:description xml:lang="id-ID">A central venous catheter is a catheter that is placed directly on a large vein in the body and its tip lies in one of the central veins that is often used on critical care patients. Colonization of bacteria (germ) around the insertion area of the CVC is an area that is very likely to cause infection even though it has been closed by dressing. The factor that should always be considered is that the state of moisture retention occurs beneath the dressing. Moisture will cause an increase in colonization of the insertion area and increase the risk of catheter-related infection. As is known the humidity level of Indonesia with other countries is higher and the results of positive swabs in the insertion area are associated with Percutaneous Central Venous Catheter (PCVC) colonization and Catheter-related Sepsis (CRS). Transparent polyurethane and plaster gauze are two types of dressings that are different and often used. The transparent polyurethane is widely used in invasive procedures, there are still many medical staff who use plaster gauze dressings. The purpose of this study is to determine the difference in the number of germs in the CVC insertion area that are dressed using transparent polyurethane and plaster gauze. The design of this study is a quasi-experimental pretest-posttest control group with positive sampling. The number of samples is 12 for the intervention group and 11 for the control group. The intervention group performed transparent polyurethane dressings and a control group with plaster gauze. Calculation in the number of germs is with the cup count method. Wilcoxon and Mann-Whitney tests are for te data analysis. Based on the results of the study, it can be concluded that there is no difference in the number of CVC insertion germs between the use of dressings transparent polyurethane and plaster gauze so that both types of dressings can be used for CVC dressings in critical patient care settings. </dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Nursing Universitas Padjadjaran</dc:publisher>
	<dc:date>2018-12-25</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/324</dc:identifier>
	<dc:identifier>10.24198/jkp.v6i3.324</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Keperawatan Padjadjaran; Vol. 6 No. 3 (2018): Jurnal Keperawatan Padjadjaran</dc:source>
	<dc:source>2442-7276</dc:source>
	<dc:source>2338-5324</dc:source>
	<dc:source>10.24198/jkp.v6i3</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/324/201</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2018 Jurnal Keperawatan Padjadjaran</dc:rights>
</oai_dc:dc>