Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Comparison of Central Venous Pressure (Cvp) Score among Patients on Mechanical Ventilator with Head of Bed (Hob) Elevation 30O; Neutral, Right, and Left Side Positions

Jurnal Keperawatan Padjadjaran · Vol. 7 No. 1 (2019) · hlm. 20–28

DOI
10.24198/jkp.v7i1.741
ISSN
2442-7276, 2338-5324
Terbit
2019-04-11
Penerbit
Faculty of Nursing Universitas Padjadjaran
Bahasa
eng

Abstrak

Early mobilization is important for critical patients to improve cough reflexes, eliminate bronchial secretions, facilitate work of mucociliary drainage muscles, and to prevent associated pneumonia ventilators and pressure sores. However, at the same time the patient often experiences vital signs change due to fluctuating conditions. Central Venous Pressure (CVP) measurement is oftenly needed to monitor central circulatory system. Unfortunately, in the clinical setting, the patient’s position must be changed first in a 30o neutral head of bed (HoB) position rather than left or right side HoB position. This study aims to examine the differences in of CVP score among patients on mechanical ventilation at HoB position elevation 30o in a neutral, right side, and left side position. This quantitative comparative study involved 24 subjects who were recruited consecutively. Data were analyzed using ANOVA. The results showed that the mean CVP value at neutral HoB position elevation was 13.5 ± 3.96, right sight HoB elevation was 12.8 ± 4.16, and left side HoB elevation was 14.4 ± 4.17. There was a significant difference (p <0.05) among those three positions. Post hoc analysis test found the HoB position 30o neutral vs left side possition was higher and signifficantly difference with HoB elevation 30o neutral vs right side positions (p<0.05). This study suggested nurses need to consider the change of CVP values while changing patiens’ position of HoB elevation 30o neutral, right side, and left side positions. Athough there was statistically difference among three positions, in fact, the value difference was less than 1 cmH2O which clinically did not see any differences.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 80 tautan kepenulisan bersama · 13 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Padjadjaran University
  • Poltekkes Kemenkes Kendari
  • Dr. Hasan Sadikin General Hospital
  • Lincoln University College
  • Poltekkes Kemenkes Bandung
  • Lambung Mangkurat University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Laili RahayuwatiPadjadjaran University3
Aat SriatiPadjadjaran University3
Aan NuraeniPadjadjaran University3
Anita SetyawatiPadjadjaran University3
La RangkiPadjadjaran University2
Yusshy Kurnia HerlianiPadjadjaran University2
Hasniatisari HarunPadjadjaran University2
Aan Nur'ainiAfiliasi tidak diketahui1
Lilin RosyantiPoltekkes Kemenkes Kendari1
Indriono HadiPoltekkes Kemenkes Kendari1
Maria KomariahPadjadjaran University1
Lilis LismayantiLincoln University College1
Lia MeilianingsihPoltekkes Kemenkes Bandung1
Derison Marsinova BakaraAfiliasi tidak diketahui1
Hana RizmadewiAfiliasi tidak diketahui1
Hana Rizmadewi AgustinaPadjadjaran University1
Meilita EngguneAfiliasi tidak diketahui1
Septian AndriyaniAfiliasi tidak diketahui1
Sri WulandariAfiliasi tidak diketahui1
Didi KurniawanAfiliasi tidak diketahui1
Ayu PrawestiPadjadjaran University1
Fransisca Sri SusilaningsihPadjadjaran University1
Baskoro SoetioputroPadjadjaran University1
Ida RosidawatiAfiliasi tidak diketahui1
N NursiswatiPadjadjaran University1
Ayu Prawesti PriambodoPadjadjaran University1
Titis KurniawanPadjadjaran University1
Yeni YuliantiPadjadjaran University1
Baiq Emi NurmalisaAfiliasi tidak diketahui1
Siti Ulfah Rifa’atul FitriAfiliasi tidak diketahui1
Alfian AlfianLambung Mangkurat University1
Imas RafiyahPadjadjaran University1
Yanny Trisyani WPadjadjaran University1
Ni Putu Wahyu ArianiPadjadjaran University1
Sri HendrawatiPadjadjaran University1
Ikeu NurhidayahPadjadjaran University1
S.Kp., MsC, Iqbal PramuktiAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://jkp.fkep.unpad.ac.id/index.php/jkp/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="id-ID">Comparison of Central Venous Pressure (Cvp) Score among Patients on Mechanical Ventilator with Head of Bed (Hob) Elevation 30O; Neutral, Right, and Left Side Positions</dc:title>
	<dc:creator>Setiyawan, Setiyawan</dc:creator>
	<dc:creator>Ibrahim, Kusman</dc:creator>
	<dc:creator>Mulyati, Titin</dc:creator>
	<dc:subject xml:lang="id-ID">Central venous pressure</dc:subject>
	<dc:subject xml:lang="id-ID">HoB elevation</dc:subject>
	<dc:subject xml:lang="id-ID">Mechanical ventilation</dc:subject>
	<dc:description xml:lang="id-ID">Early mobilization is important for critical patients to improve cough reflexes, eliminate bronchial secretions, facilitate work of mucociliary drainage muscles, and to prevent associated pneumonia ventilators and pressure sores. However, at the same time the patient often experiences vital signs change due to fluctuating conditions. Central Venous Pressure (CVP) measurement is oftenly needed to monitor central circulatory system. Unfortunately, in the clinical setting, the patient’s position must be changed first in a 30o neutral head of bed (HoB) position rather than left or right side HoB position. This study aims to examine the differences in of CVP score among patients on mechanical ventilation at HoB position elevation 30o in a neutral, right side, and left side position. This quantitative comparative study involved 24 subjects who were recruited consecutively. Data were analyzed using ANOVA. The results showed that the mean CVP value at neutral HoB position elevation was 13.5 ± 3.96, right sight HoB elevation was 12.8 ± 4.16, and left side HoB elevation was 14.4 ± 4.17. There was a significant difference (p &amp;lt;0.05) among those three positions. Post hoc analysis test found the HoB position 30o neutral vs left side possition was higher and signifficantly difference with HoB elevation 30o neutral vs right side positions (p&amp;lt;0.05). This study suggested nurses need to consider the change of CVP values while changing patiens’ position of HoB elevation 30o neutral, right side, and left side positions. Athough there was statistically difference among three positions, in fact, the value difference was less than 1 cmH2O which clinically did not see any differences.</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Nursing Universitas Padjadjaran</dc:publisher>
	<dc:date>2019-04-11</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/741</dc:identifier>
	<dc:identifier>10.24198/jkp.v7i1.741</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Keperawatan Padjadjaran; Vol. 7 No. 1 (2019): Jurnal Keperawatan Padjadjaran; 20-28</dc:source>
	<dc:source>2442-7276</dc:source>
	<dc:source>2338-5324</dc:source>
	<dc:source>10.24198/jkp.v7i1</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/741/211</dc:relation>
	<dc:relation>10.24198/jkp.v7i1.741.g211</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2019 Jurnal Keperawatan Padjadjaran</dc:rights>
</oai_dc:dc>