Melola Discovery

← Melola Discovery

Akses terbuka Jurnal SINTA 1

The Effect of Lateral Position with Head Up 45° on Oxygenation in Pleural Effusion Patients

Jurnal Keperawatan Padjadjaran · Vol. 9 No. 2 (2021) · hlm. 124–130

DOI
10.24198/jkp.v9i2.1672
ISSN
2442-7276, 2338-5324
Terbit
2021-08-31
Penerbit
Faculty of Nursing Universitas Padjadjaran
Bahasa
eng
Lisensi
creativecommons.org/licenses/by-sa/4.0

Abstrak

Background: The accumulation of fluid in the pleural cavity will interfere with the restriction process, namely disruption of lung expansion so that the air entering the lungs is less than normal. One of the effects is shortness of breath and a decrease in oxygen saturation. In this case, nursing actions play an important role in inadequate ventilation, namely positioning. The lateral position is one of the recommended positions for patients with unilateral lung disease, one of which is unilateral pleural effusion. Position selection is very important to facilitate adequate breathing, namely one with a head-up of 45°. According to some literature, the 45° head-up position can reduce consumption and maximize lung expansion which will result in greater ventilation. Purpose: To determine the effect of the lateral position with a head-up 45° on oxygen saturation and respiratory rate in a patient with unilateral pleural effusion at the Dr. H. A. Rotinsulu Lung Hospital Bandung. Methods: The research design was a quasi-experimental design with one group pre and post-test design with a sample of 44 people. The sampling technique used consecutive sampling. The results showed that there were differences in median oxygen saturation and respiratory rate before and after the intervention. Results: The results of a comparative study using the Wilcoxon test obtained a p value of 0.0001 (p value<0.05). There is an effect of giving a lateral position with a head-up 45° on increasing oxygen saturation and decreasing respiratory rate. Conclusion: Thus, it is expected for the service unit to establish a lateral position in the direction of the effusion with a head-up of 45° as the operational standard for the management of unilateral pleural effusion impaired oxygenation patients.

Kata kunci

Jaringan kolaborasi para penulis

17 penulis · 32 tautan kepenulisan bersama · 6 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Padjadjaran University
  • Dr. Hasan Sadikin General Hospital
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Kusman IbrahimPadjadjaran University1
N NursiswatiPadjadjaran University1
Zustantria Agustin MinggawatiAfiliasi tidak diketahui1
Achmad FariedPadjadjaran University1
Wiwi MardiahPadjadjaran University1
Sri HendrawatiPadjadjaran University1
Aan Nur'aeniAfiliasi tidak diketahui1
SKp., MNS., PhD, Kusman IbrahimAfiliasi tidak diketahui1
Endah Nurul AiniDr. Hasan Sadikin General Hospital1
Uun SumardiDr. Hasan Sadikin General Hospital1
Yovita HartantriPadjadjaran University1
Adhi Kristianto SugianliDr. Hasan Sadikin General Hospital1
Aan NuraeniPadjadjaran University1
Selly DesianiPadjadjaran University1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://jkp.fkep.unpad.ac.id/index.php/jkp/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 16 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">The  Effect of Lateral Position with Head Up 45° on Oxygenation in Pleural Effusion Patients</dc:title>
	<dc:creator>Rahmawati, Endah Yuliany</dc:creator>
	<dc:creator>Pranggono, Emmy H</dc:creator>
	<dc:creator>Priambodo, Ayu Prawesti</dc:creator>
	<dc:subject xml:lang="en-US">Gas exchange</dc:subject>
	<dc:subject xml:lang="en-US">lateral positioning</dc:subject>
	<dc:subject xml:lang="en-US">pleural effusion</dc:subject>
	<dc:subject xml:lang="en-US">unilateral lung disease</dc:subject>
	<dc:description xml:lang="en-US">Background: The accumulation of fluid in the pleural cavity will interfere with the restriction process, namely disruption of lung expansion so that the air entering the lungs is less than normal. One of the effects is shortness of breath and a decrease in oxygen saturation. In this case, nursing actions play an important role in inadequate ventilation, namely positioning. The lateral position is one of the recommended positions for patients with unilateral lung disease, one of which is unilateral pleural effusion. Position selection is very important to facilitate adequate breathing, namely one with a head-up of 45°. According to some literature, the 45° head-up position can reduce consumption and maximize lung expansion which will result in greater ventilation.
Purpose: To determine the effect of the lateral position with a head-up 45° on oxygen saturation and respiratory rate in a patient with unilateral pleural effusion at the Dr. H. A. Rotinsulu Lung Hospital Bandung.
Methods: The research design was a quasi-experimental design with one group pre and post-test design with a sample of 44 people. The sampling technique used consecutive sampling. The results showed that there were differences in median oxygen saturation and respiratory rate before and after the intervention.
Results: The results of a comparative study using the Wilcoxon test obtained a p value of 0.0001 (p value&amp;lt;0.05). There is an effect of giving a lateral position with a head-up 45° on increasing oxygen saturation and decreasing respiratory rate.
Conclusion: Thus, it is expected for the service unit to establish a lateral position in the direction of the effusion with a head-up of 45° as the operational standard for the management of unilateral pleural effusion impaired oxygenation patients.</dc:description>
	<dc:publisher xml:lang="en-US">Faculty of Nursing Universitas Padjadjaran</dc:publisher>
	<dc:date>2021-08-31</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/1672</dc:identifier>
	<dc:identifier>10.24198/jkp.v9i2.1672</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Keperawatan Padjadjaran; Vol. 9 No. 2 (2021): Jurnal Keperawatan Padjadjaran; 124-130</dc:source>
	<dc:source>2442-7276</dc:source>
	<dc:source>2338-5324</dc:source>
	<dc:source>10.24198/jkp.v9i2</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://jkp.fkep.unpad.ac.id/index.php/jkp/article/view/1672/291</dc:relation>
	<dc:relation>10.24198/jkp.v9i2.1672.g291</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2021 Endah Yuliany Rahmawati, Emmy H Pranggono, Ayu Prawesti Priambodo</dc:rights>
	<dc:rights xml:lang="en-US">https://creativecommons.org/licenses/by-sa/4.0</dc:rights>
</oai_dc:dc>