Comparison between the QRMA Measurement with the Anamnesis and the Capillary Blood Glucose Test

Jurnal Ners · Vol. 14 No. 2 (2020) · hlm. 224–230

DOI
10.20473/jn.v14i2.6154
ISSN
2502-5791, 1858-3598
Terbit
2020-01-21
Penerbit
Universitas Airlangga
Bahasa
eng

Abstrak

ABSTRACTIntroduction: The examination of patients with diabetes mellitus (DM) can be done by reviewing their complaints and through a capillary blood glucose level test to determine the value of their Random Blood Glucose Level. QRMA (Quantum Resonance Magnetic Analyzer) is claimed to be able to check the patient's bodily condition (including blood glucose) with an accuracy of 85%. The purpose of this study was to verify the validity of the QRMA tool and its accuracy by comparing the results of the anamnesis and the examination conducted using the capillary blood glucose test method.Methods: The research method used was a cross-sectional design. The total sample consisted of 44 respondents in the working area of the Community Health Centers in Yogyakarta with the risk factor being blood sugar level instability. The sampling technique used was purposive sampling. The main variable in this study was the value of the blood sugar level measured based on the coefficient value of the QRMA tool and the value of Random Blood Glucose obtained through the capillary blood glucose test.Results: The blood glucose value was not correlated significantly with the coefficient value of QRMA. The value of blood glucose when examined alongside the result of the respondent's anamnesis showed there to be a significant difference. The value of the QRMA coefficient when examined against the results from the history of the respondents showed no significant difference. Linear regression showed that the variables of height, body weight, and IMT had a correlation with the QRMA coefficient value.Conclusion: The QRMA tool was not able to provide a picture of the actual condition of the blood glucose level of the respondents when compared with the results of the anamnesis and the blood glucose value from the capillary blood glucose test. Non-invasive health measurement devices such as QRMA are not used by nurses as a standard for determining the health status of DM patients.

Kata kunci

Jaringan kolaborasi para penulis

13 penulis · 23 tautan kepenulisan bersama · 2 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universitas Respati Yogyakarta
  • Universitas 'Aisyiyah Yogyakarta
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Siti FadlilahUniversitas Respati Yogyakarta1
Ariyanto NughrohoUniversitas 'Aisyiyah Yogyakarta1
Rahayu WidaryantiUniversitas Respati Yogyakarta1
Tri Mei KhasanaUniversitas Respati Yogyakarta1
Dheska Arthyka PalifianaUniversitas Respati Yogyakarta1
Nur AlviraUniversitas Respati Yogyakarta1
Eka Silvia SaputriUniversitas Respati Yogyakarta1
Rizky ErwantoUniversitas Respati Yogyakarta1
Venny VidayantiUniversitas Respati Yogyakarta1
Deden Iwan SetiawanAfiliasi tidak diketahui1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) http://e-journal.unair.ac.id/index.php/JNERS/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Comparison between the QRMA Measurement with the Anamnesis and the Capillary Blood Glucose Test</dc:title>
	<dc:creator>Muflih, Muflih</dc:creator>
	<dc:creator>Suwarsi, Suwarsi</dc:creator>
	<dc:creator>Asmarani, Fajarina Lathu</dc:creator>
	<dc:subject xml:lang="en-US">Anamneses</dc:subject>
	<dc:subject xml:lang="en-US">Blood Glucose</dc:subject>
	<dc:subject xml:lang="en-US">QRMA</dc:subject>
	<dc:description xml:lang="en-US">ABSTRACTIntroduction: The examination of patients with diabetes mellitus (DM) can be done by reviewing their complaints and through a capillary blood glucose level test to determine the value of their Random Blood Glucose Level. QRMA (Quantum Resonance Magnetic Analyzer) is claimed to be able to check the patient's bodily condition (including blood glucose) with an accuracy of 85%. The purpose of this study was to verify the validity of the QRMA tool and its accuracy by comparing the results of the anamnesis and the examination conducted using the capillary blood glucose test method.Methods: The research method used was a cross-sectional design. The total sample consisted of 44 respondents in the working area of the Community Health Centers in Yogyakarta with the risk factor being blood sugar level instability. The sampling technique used was purposive sampling. The main variable in this study was the value of the blood sugar level measured based on the coefficient value of the QRMA tool and the value of Random Blood Glucose obtained through the capillary blood glucose test.Results: The blood glucose value was not correlated significantly with the coefficient value of QRMA. The value of blood glucose when examined alongside the result of the respondent's anamnesis showed there to be a significant difference. The value of the QRMA coefficient when examined against the results from the history of the respondents showed no significant difference. Linear regression showed that the variables of height, body weight, and IMT had a correlation with the QRMA coefficient value.Conclusion: The QRMA tool was not able to provide a picture of the actual condition of the blood glucose level of the respondents when compared with the results of the anamnesis and the blood glucose value from the capillary blood glucose test. Non-invasive health measurement devices such as QRMA are not used by nurses as a standard for determining the health status of DM patients.</dc:description>
	<dc:publisher xml:lang="en-US">Universitas Airlangga</dc:publisher>
	<dc:date>2020-01-21</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://e-journal.unair.ac.id/JNERS/article/view/6154</dc:identifier>
	<dc:identifier>10.20473/jn.v14i2.6154</dc:identifier>
	<dc:source xml:lang="en-US">Jurnal Ners; Vol. 14 No. 2 (2019): OCTOBER 2019; 224-230</dc:source>
	<dc:source>2502-5791</dc:source>
	<dc:source>1858-3598</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://e-journal.unair.ac.id/JNERS/article/view/6154/pdf</dc:relation>
	<dc:rights xml:lang="en-US">Copyright (c) 2020 Jurnal Ners</dc:rights>
</oai_dc:dc>