Adjusting Time of Flight in Ultrasound B-mode Imaging for Accurate Measurement of Fat using Image Segmentation Technique

Journal of ICT Research and Applications (JICTRA) · Vol. 11 No. 1 (2017) · hlm. 1–20

DOI
10.5614/itbj.ict.res.appl.2017.11.1.1
ISSN
2338-5499, 2337-5787
Terbit
2017-04-30
Penerbit
DRI - ITB
Bahasa
eng

Abstrak

This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined ultrasonic velocity in conventional B-mode imaging. The pre-determined velocity is replaced by actual velocity measured using A-mode imaging. The positioning accuracy of adapted and conventional B-mode imaging was validated using 144 chicken samples. The adapted B-mode image had better positioning accuracy compared to a conventional B-mode image since the method used was able to detect the thickness of the chicken sample with a lower mean difference (0.036±0.034mm vs. 0.113±0.010). Both methods were then applied for measurement of intramuscular fat content. The histogram mean and the percentage of fat pixels were the B-mode image characteristics that were extracted and their correlation with the fat content, measured using the Soxhlet method, was analyzed. The properties of the adapted B-mode images correlated better with the Soxhlet-measured fat content compared to the properties of the conventional B-mode images as reflected in the correlation coefficient, r, for the histogram mean (0.357 vs. 0.129) and the percentage of fat pixels (0.406 vs. 0.289). The results indicate the potential of using ultrasound adapted B-mode imaging to measure chicken intramuscular fat.

Kata kunci

Jaringan kolaborasi para penulis

2 penulis · 1 tautan kepenulisan bersama · 1 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Teknologi MARA
  • SEGi University
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journals.itb.ac.id/index.php/jictra/oai, pertama di-harvest 26 Okt 2026, terakhir terlihat 15 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en-US">Adjusting Time of Flight in Ultrasound B-mode Imaging for Accurate Measurement of Fat using Image Segmentation Technique</dc:title>
	<dc:creator>Buniyamin, Norlida</dc:creator>
	<dc:creator>Halim, M. Hazwan Abdul</dc:creator>
	<dc:subject xml:lang="en-US">chicken fat</dc:subject>
	<dc:subject xml:lang="en-US">histogram mean</dc:subject>
	<dc:subject xml:lang="en-US">percentage of fat pixels</dc:subject>
	<dc:subject xml:lang="en-US">phase error</dc:subject>
	<dc:subject xml:lang="en-US">Soxhlet method</dc:subject>
	<dc:subject xml:lang="en-US">ultrasound B-mode.</dc:subject>
	<dc:description xml:lang="en-US">This research attempted to measure chicken intramuscular fat content using improved ultrasound B-mode images and image segmentation. Adapted B-mode imaging is proposed to increase the positioning accuracy of B-mode images with the objective to correct the phase error due to the use of predetermined ultrasonic velocity in conventional B-mode imaging. The pre-determined velocity is replaced by actual velocity measured using A-mode imaging. The positioning accuracy of adapted and conventional B-mode imaging was validated using 144 chicken samples. The adapted B-mode image had better positioning accuracy compared to a conventional B-mode image since the method used was able to detect the thickness of the chicken sample with a lower mean difference (0.036±0.034mm vs. 0.113±0.010). Both methods were then applied for measurement of intramuscular fat content. The histogram mean and the percentage of fat pixels were the B-mode image characteristics that were extracted and their correlation with the fat content, measured using the Soxhlet method, was analyzed. The properties of the adapted B-mode images correlated better with the Soxhlet-measured fat content compared to the properties of the conventional B-mode images as reflected in the correlation coefficient, r, for the histogram mean (0.357 vs. 0.129) and the percentage of fat pixels (0.406 vs. 0.289). The results indicate the potential of using ultrasound adapted B-mode imaging to measure chicken intramuscular fat.</dc:description>
	<dc:publisher xml:lang="en-US">DRI - ITB</dc:publisher>
	<dc:date>2017-04-30</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:type xml:lang="en-US">Peer-reviewed Article</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journals.itb.ac.id/index.php/jictra/article/view/1875</dc:identifier>
	<dc:identifier>10.5614/itbj.ict.res.appl.2017.11.1.1</dc:identifier>
	<dc:source xml:lang="en-US">Journal of ICT Research and Applications; Vol. 11 No. 1 (2017); 1-20</dc:source>
	<dc:source>2338-5499</dc:source>
	<dc:source>2337-5787</dc:source>
	<dc:language>eng</dc:language>
	<dc:relation>https://journals.itb.ac.id/index.php/jictra/article/view/1875/2506</dc:relation>
</oai_dc:dc>