The Effect of Excess Heat Utilization on the Production Cost of Cement

Mechanical Engineering for Society and Industry · Vol. 1 No. 2 (2021) · hlm. 104–114

DOI
10.31603/mesi.5987
ISSN
2798-5245
Terbit
2021-12-04
Penerbit
Universitas Muhammadiyah Magelang
Bahasa
en

Abstrak

Industrial excess heat is a largely untapped resource that has the potential for external use that would be beneficial to the cement industry. Therefore, this work studied the excess heat utilization for the optimization of production cost in a cement plant within a period of three years. The study of plant layout in the selected plant in Nigeria (Ewekoro II Cement Plant of 200 tonnes/hour) was carried out to identify areas where excess heat is generated. The temperature and static pressure of precalciner, kiln, and cyclone were taken using a temperature probe, pitot tube, digital manometer, and light-emitting diode temperature reader. These parameters were used to obtain the mass flow rate and heat transfer needed for the heat energy analysis of the system. The kiln was maintained at constant tonnage per hour through a clinker truck weighed using the weighbridge. The result showed that the heat generated from the kiln was 577,640,260 MJ/hr. through excess air draft of 780,000 m3/hr (89.4%) at 250 °C and induced draft fan of 900,000 m3/hr at 350 °C. The result showed that excess heat can be utilized in pre-heater and air quenched cooler boilers, steam turbines and auxiliaries, and generators. The total estimated heat that could be saved amounted to 344,648,250 MJ with a total annual capacity of 2.25 million tonnes of cement. A saving of over two billion dollars could be achieved in production cost per year.

Kata kunci

Jaringan kolaborasi para penulis

8 penulis · 22 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Federal University of Agriculture, Abeokuta
  • Olabisi Onabanjo University
  • Osun State University
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Ayodele M. AdedayoAfiliasi tidak diketahui3
Salami O. IsmailiaAfiliasi tidak diketahui3
Olanrewaju M. AdesusiAfiliasi tidak diketahui3

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unimma.ac.id/index.php/mesi/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">The Effect of Excess Heat Utilization on the Production Cost of Cement</dc:title>
	<dc:creator xml:lang="en">Adetunji, Olayide R.</dc:creator>
	<dc:creator xml:lang="en">Ogbuokiri, Montfort C.</dc:creator>
	<dc:creator xml:lang="en">Dairo, Olawale U.</dc:creator>
	<dc:creator xml:lang="en">Olatunde, Olanrewaju B.</dc:creator>
	<dc:creator xml:lang="en">Okediran, Iliyas K.</dc:creator>
	<dc:subject xml:lang="en">Cement</dc:subject>
	<dc:subject xml:lang="en">Production cost</dc:subject>
	<dc:subject xml:lang="en">Excess heat utilisation</dc:subject>
	<dc:subject xml:lang="en">Energy saving</dc:subject>
	<dc:description xml:lang="en">Industrial excess heat is a largely untapped resource that has the potential for external use that would be beneficial to the cement industry. Therefore, this work studied the excess heat utilization for the optimization of production cost in a cement plant within a period of three years. The study of plant layout in the selected plant in Nigeria (Ewekoro II Cement Plant of 200 tonnes/hour) was carried out to identify areas where excess heat is generated. The temperature and static pressure of precalciner, kiln, and cyclone were taken using a temperature probe, pitot tube, digital manometer, and light-emitting diode temperature reader. These parameters were used to obtain the mass flow rate and heat transfer needed for the heat energy analysis of the system. The kiln was maintained at constant tonnage per hour through a clinker truck weighed using the weighbridge. The result showed that the heat generated from the kiln was 577,640,260 MJ/hr. through excess air draft of 780,000 m3/hr (89.4%) at 250 °C and induced draft fan of 900,000 m3/hr at 350 °C. The result showed that excess heat can be utilized in pre-heater and air quenched cooler boilers, steam turbines and auxiliaries, and generators. The total estimated heat that could be saved amounted to 344,648,250 MJ with a total annual capacity of 2.25 million tonnes of cement. A saving of over two billion dollars could be achieved in production cost per year.</dc:description>
	<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
	<dc:date>2021-12-04</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unimma.ac.id/mesi/article/view/5987</dc:identifier>
	<dc:identifier>10.31603/mesi.5987</dc:identifier>
	<dc:source xml:lang="en">Mechanical Engineering for Society and Industry; Vol. 1 No. 2 (2021); 104-114</dc:source>
	<dc:source>2798-5245</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unimma.ac.id/mesi/article/view/5987/2888</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2021 Olayide R. Adetunji, Montfort C. Ogbuokiri, Olawale U. Dairo, Olanrewaju B. Olatunde, Iliyas K. Okediran</dc:rights>
</oai_dc:dc>