Investigation and failure analysis of a diesel generator connecting rod

Mechanical Engineering for Society and Industry · Vol. 2 No. 2 (2022) · hlm. 64–71

DOI
10.31603/mesi.6624
ISSN
2798-5245
Terbit
2022-05-20
Penerbit
Universitas Muhammadiyah Magelang
Bahasa
en

Abstrak

This article reports a failure analysis of a diesel generator set connecting rod type 3516 B that has operated for 79,678 hours. From visual observation, connecting rod cylinder #10 has changed color in the shank area. This phenomenon may represent many cases of generator failure, so an analysis to identify the root cause of the failure is needed for scientific literature. In this case, fault tree analysis, SEM-EDX, chemical composition, and microstructure testing were performed to obtain more comprehensive results. Through fault tree analysis, we found that the connecting rod damage was caused by compression leakage due to wear on the cylinder liner. Scanning Electron Microscopy (SEM) analysis shows that the piston rod material is discolored due to heat, namely the formation of iron oxide. The heat level received by the connecting rod is around 200 °C. We also found a finely formed, easy-to-clean scale where the thickness ranged from 0.00127–0.008 mm. Finally, EDX analysis showed high levels of iron (Fe) and oxygen (O) confirming that the formation of iron-oxide on the metal surface was due to the influence of heat.

Kata kunci

Jaringan kolaborasi para penulis

15 penulis · 32 tautan kepenulisan bersama · 3 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Universiti Malaysia Terengganu
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
J. S. NorbakyahUniversiti Malaysia Terengganu1
I. N. AnidaUniversiti Malaysia Terengganu1
A. R. SalisaUniversiti Malaysia Terengganu1
M. I. NordiyanaUniversiti Malaysia Terengganu1
Nurkholis NurkholisAfiliasi tidak diketahui1
M. Ali PahmiAfiliasi tidak diketahui1
Firman FirmanAfiliasi tidak diketahui1
Muhammad MujtabaAfiliasi tidak diketahui1
Bamidele Victor AyodeleUniversiti Malaysia Pahang Al-Sultan Abdullah1
Sureena Binti AbdullahUniversiti Malaysia Pahang Al-Sultan Abdullah1
Norashima AbdullahUniversiti Malaysia Pahang Al-Sultan Abdullah1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unimma.ac.id/index.php/mesi/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Investigation and failure analysis of a diesel generator connecting rod</dc:title>
	<dc:creator xml:lang="en">Wilarso, Wilarso</dc:creator>
	<dc:creator xml:lang="en">Noor, Che Wan Mohd</dc:creator>
	<dc:creator xml:lang="en">Ayob, Ahmad Faisal Mohamad</dc:creator>
	<dc:creator xml:lang="en">Mansor, Wan Nurdiyana Wan</dc:creator>
	<dc:subject xml:lang="en">Connecting Rod</dc:subject>
	<dc:subject xml:lang="en">Microstructure</dc:subject>
	<dc:subject xml:lang="en">SEM-EDX</dc:subject>
	<dc:subject xml:lang="en">Fault tree analysis</dc:subject>
	<dc:description xml:lang="en">This article reports a failure analysis of a diesel generator set connecting rod type 3516 B that has operated for 79,678 hours. From visual observation, connecting rod cylinder #10 has changed color in the shank area. This phenomenon may represent many cases of generator failure, so an analysis to identify the root cause of the failure is needed for scientific literature. In this case, fault tree analysis, SEM-EDX, chemical composition, and microstructure testing were performed to obtain more comprehensive results. Through fault tree analysis, we found that the connecting rod damage was caused by compression leakage due to wear on the cylinder liner. Scanning Electron Microscopy (SEM) analysis shows that the piston rod material is discolored due to heat, namely the formation of iron oxide. The heat level received by the connecting rod is around 200 °C. We also found a finely formed, easy-to-clean scale where the thickness ranged from 0.00127–0.008 mm. Finally, EDX analysis showed high levels of iron (Fe) and oxygen (O) confirming that the formation of iron-oxide on the metal surface was due to the influence of heat.</dc:description>
	<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
	<dc:date>2022-05-20</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unimma.ac.id/mesi/article/view/6624</dc:identifier>
	<dc:identifier>10.31603/mesi.6624</dc:identifier>
	<dc:source xml:lang="en">Mechanical Engineering for Society and Industry; Vol. 2 No. 2 (2022); 64-71</dc:source>
	<dc:source>2798-5245</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unimma.ac.id/mesi/article/view/6624/3304</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2022 Wilarso Wilarso, Che Wan Mohd Noor, Ahmad Faisal Mohamad Ayob, Wan Nurdiyana Wan Mansor</dc:rights>
</oai_dc:dc>