Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems

Mechanical Engineering for Society and Industry · Vol. 3 No. 1 (2023) · hlm. 35–46

DOI
10.31603/mesi.8591
ISSN
2798-5245
Terbit
2023-01-23
Penerbit
Universitas Muhammadiyah Magelang
Bahasa
en

Abstrak

Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming. Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate. In addition to the issue of refrigerant high GWP, energy consumption is a significant issue. The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source. Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems. Relevant thermodynamic equations and REFPROP software were employed for the computational analysis. The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications. The blends also exhibited low compressor energy input and low specific cooling energy. R455A has an average coefficient of performance (COP) of 24.6% above that of the reference refrigerant (R410A). The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.3, 6.0, and 12.6%, respectively than that of R410A. Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy. R455A also has the highest COP and relatively high cooling capacity per unit volume.

Kata kunci

Jaringan kolaborasi para penulis

9 penulis · 15 tautan kepenulisan bersama · 13 lintas organisasi

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • Federal University Oye Ekiti
  • Federal University of Agriculture, Abeokuta
  • Federal University Otuoke
  • Hydraulic Equipment Development Institute Kano
  • Yaba College of Technology
  • Universidade Federal de Uberlândia
  • Universitas Muhammadiyah Magelang
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Olatunde Ajani OyelaranHydraulic Equipment Development Institute Kano1
Mufutau Adekojo WaheedFederal University of Agriculture, Abeokuta1
Micheal F AdekunleFederal University of Agriculture, Abeokuta1
Saheed Olalekan HammedYaba College of Technology1
Antonio Marcos Gonçalves de LimaUniversidade Federal de Uberlândia1
Ilham HabibiUniversitas Muhammadiyah Magelang1

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unimma.ac.id/index.php/mesi/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 22 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems</dc:title>
	<dc:creator xml:lang="en">Bolaji, Bukola Olalekan</dc:creator>
	<dc:creator xml:lang="en">Bolaji, Deborah Olufunke</dc:creator>
	<dc:creator xml:lang="en">Amosun, Semiu Taiwo</dc:creator>
	<dc:subject xml:lang="en">Air-conditioning</dc:subject>
	<dc:subject xml:lang="en">CO2</dc:subject>
	<dc:subject xml:lang="en">Cooling energy</dc:subject>
	<dc:subject xml:lang="en">Eco-friendly</dc:subject>
	<dc:subject xml:lang="en">R410A</dc:subject>
	<dc:subject xml:lang="en">Refrigerant blends</dc:subject>
	<dc:description xml:lang="en">Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming. Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate. In addition to the issue of refrigerant high GWP, energy consumption is a significant issue. The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source. Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems. Relevant thermodynamic equations and REFPROP software were employed for the computational analysis. The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications. The blends also exhibited low compressor energy input and low specific cooling energy. R455A has an average coefficient of performance (COP) of 24.6% above that of the reference refrigerant (R410A). The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.3, 6.0, and 12.6%, respectively than that of R410A. Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy. R455A also has the highest COP and relatively high cooling capacity per unit volume.</dc:description>
	<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
	<dc:date>2023-01-23</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unimma.ac.id/mesi/article/view/8591</dc:identifier>
	<dc:identifier>10.31603/mesi.8591</dc:identifier>
	<dc:source xml:lang="en">Mechanical Engineering for Society and Industry; Vol. 3 No. 1 (2023); 35-46</dc:source>
	<dc:source>2798-5245</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unimma.ac.id/mesi/article/view/8591/3965</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2023 Bukola Olalekan Bolaji, Deborah Olufunke Bolaji, Semiu Taiwo Amosun</dc:rights>
</oai_dc:dc>