Melola Discovery

← Melola Discovery

Jurnal SINTA 1

Design, fabrication, and performance testing of an energy storage and return (ESAR) foot prosthesis made of prepreg carbon composite

Mechanical Engineering for Society and Industry · Vol. 5 No. 1 (2025) · hlm. 20–32

DOI
10.31603/mesi.12652
ISSN
2798-5245
Terbit
2025-01-14
Penerbit
Universitas Muhammadiyah Magelang
Bahasa
en

Abstrak

The high demand for prosthetics in Indonesia is not followed by the ability and quality of local production to fulfill the community's needs. There is a lack of comprehensive data regarding the specific challenges encountered by local prosthetic manufacturers in Indonesia, particularly in terms of technological limitations. This study aims to understand the effect of design parameters on the performance of the energy storage and return (ESAR) foot prosthesis prototype in normal walking activities for amputees. Three different designs were created according to commercial products, and a convergence test was conducted to ensure accurate results. Finite element method (FEM) analysis was used to determine the amount of deformation that occurred in each design made when applied with 824 N axial force. The ESAR foot prosthesis prototype made from carbon prepreg was fabricated using an out-of-autoclave method, and the mechanical testing was performed with a compressive test. The results indicated that the optimal design for the ESAR foot prosthesis determined by the decision matrix scoring criteria was Design 3. The final scores for Designs 1, 2, and 3 were 54, 53, and 77, respectively. Design 3 is the easiest to manufacture, has the slightest complexity, and the lightest mass, and undergoes the least deformation during simulation, although it is the least attractive. The study found a significant difference in displacement between the deflections obtained from simulation and experiment. This occurred because the prototype was found to have delamination, which decreased the load-bearing ability of the prototype during compressive testing. Compressive testing on the prototype yielded a deflection of 22.695 mm in heel strike and 18.065 mm in toe-off positions, while FEM analysis showed 16.377 mm and 3.912 mm. Therefore, strict quality control is essential, especially when using materials such as carbon prepreg, which are prone to delamination if not properly processed.

Kata kunci

Jaringan kolaborasi para penulis

40 penulis · 145 tautan kepenulisan bersama · 97 lintas organisasi · menampilkan 40 yang paling banyak terhubung

Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.

  • State University of Semarang
  • Diponegoro University
  • Universitas Muhammadiyah Magelang
  • Universiti Malaysia Pahang Al-Sultan Abdullah
  • Indian Maritime University
  • INTI International University
  • Universitas Halu Oleo
  • Organisasi lain
  • Afiliasi tidak diketahui
  • Organisasi berbeda
  • Organisasi sama
  • Afiliasi tidak diketahui
  • Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Rekan penulisOrganisasiArtikel bersama
Tezara CionitaINTI International University17
Aditya KolakotiIndian Maritime University10
Al Ichlas ImranUniversitas Halu Oleo9
Rahmat Doni WidodoState University of Semarang8
Samsudin AnisState University of Semarang8
Muhammad Latifur RochmanUniversitas Muhammadiyah Magelang7
Jamiluddin JaafarTun Hussein Onn University of Malaysia7
KriswantoState University of Semarang6
J. JamariDiponegoro University5
Budi WaluyoUniversitas Muhammadiyah Magelang5
Agustinus Purna IrawanTarumanagara University5
JamariDiponegoro University4
R. ThirunavukkarasuAfiliasi tidak diketahui4
Dori YuvendaUniversitas Negeri Padang4
KriswantoAfiliasi tidak diketahui3
DhiaulhaqueDiponegoro University3
Tuessi Ari PurnomoUniversitas Muhammadiyah Magelang3
Indra Chandra SetiawanPancasila University3
Asep Bayu Dani NandiyantoIndonesia University of Education3
Bagiyo Condro PurnomoUniversitas Muhammadiyah Magelang3
Retno RusdjijatiUniversitas Muhammadiyah Magelang3
Ruben Bayu KristiawanState University of Semarang2
Khoirul HudaState University of Semarang2
Febri Budi DarsonoState University of Semarang2
Mohd Syahmi JamaludinUniversiti Malaysia Sarawak2
SukarniState University of Malang2
Sonika MaulanaState University of Semarang2
Djoko Wahyu KarmiadjiNational Research and Innovation Agency2
Muchamad GozaliBadan Pengkajian dan Penerapan Teknologi2
Yusuf Dewantoro HerlambangPoliteknik Negeri Semarang2
Gunawan RefiadiUniversitas Sebelas April2

Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.

Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unimma.ac.id/index.php/mesi/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/  http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
	<dc:title xml:lang="en">Design, fabrication, and performance testing of an energy storage and return (ESAR) foot prosthesis made of prepreg carbon composite</dc:title>
	<dc:creator xml:lang="en">Ismail, Rifky</dc:creator>
	<dc:creator xml:lang="en">Nursafitri, Murti Ayu</dc:creator>
	<dc:creator xml:lang="en">Fardinansyah, Akmal Putra</dc:creator>
	<dc:creator xml:lang="en">Fitriyana, Deni Fajar</dc:creator>
	<dc:creator xml:lang="en">Bayuseno, Athanasius Priharyoto</dc:creator>
	<dc:creator xml:lang="en">Siregar, Januar Parlaungan</dc:creator>
	<dc:creator xml:lang="en">Setiyo, Muji</dc:creator>
	<dc:creator xml:lang="en">Istiqomah, Alfiana Fitri</dc:creator>
	<dc:creator xml:lang="en">Sulistyo, Sulistyo</dc:creator>
	<dc:subject xml:lang="en">Prosthetic</dc:subject>
	<dc:subject xml:lang="en">ESAR</dc:subject>
	<dc:subject xml:lang="en">FEM</dc:subject>
	<dc:subject xml:lang="en">Carbon prepreg</dc:subject>
	<dc:subject xml:lang="en">Out-of autoclave</dc:subject>
	<dc:subject xml:lang="en">Deflection</dc:subject>
	<dc:description xml:lang="en">The high demand for prosthetics in Indonesia is not followed by the ability and quality of local production to fulfill the community's needs. There is a lack of comprehensive data regarding the specific challenges encountered by local prosthetic manufacturers in Indonesia, particularly in terms of technological limitations. This study aims to understand the effect of design parameters on the performance of the energy storage and return (ESAR) foot prosthesis prototype in normal walking activities for amputees. Three different designs were created according to commercial products, and a convergence test was conducted to ensure accurate results. Finite element method (FEM) analysis was used to determine the amount of deformation that occurred in each design made when applied with 824 N axial force. The ESAR foot prosthesis prototype made from carbon prepreg was fabricated using an out-of-autoclave method, and the mechanical testing was performed with a compressive test. The results indicated that the optimal design for the ESAR foot prosthesis determined by the decision matrix scoring criteria was Design 3. The final scores for Designs 1, 2, and 3 were 54, 53, and 77, respectively. Design 3 is the easiest to manufacture, has the slightest complexity, and the lightest mass, and undergoes the least deformation during simulation, although it is the least attractive. The study found a significant difference in displacement between the deflections obtained from simulation and experiment. This occurred because the prototype was found to have delamination, which decreased the load-bearing ability of the prototype during compressive testing. Compressive testing on the prototype yielded a deflection of 22.695 mm in heel strike and 18.065 mm in toe-off positions, while FEM analysis showed 16.377 mm and 3.912 mm. Therefore, strict quality control is essential, especially when using materials such as carbon prepreg, which are prone to delamination if not properly processed.</dc:description>
	<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
	<dc:date>2025-01-14</dc:date>
	<dc:type>info:eu-repo/semantics/article</dc:type>
	<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
	<dc:format>application/pdf</dc:format>
	<dc:identifier>https://journal.unimma.ac.id/mesi/article/view/12652</dc:identifier>
	<dc:identifier>10.31603/mesi.12652</dc:identifier>
	<dc:source xml:lang="en">Mechanical Engineering for Society and Industry; Vol. 5 No. 1 (2025); 20-32</dc:source>
	<dc:source>2798-5245</dc:source>
	<dc:language>en</dc:language>
	<dc:relation>https://journal.unimma.ac.id/mesi/article/view/12652/5579</dc:relation>
	<dc:rights xml:lang="en">Copyright (c) 2025 Rifky Ismail, Murti Ayu Nursafitri, Akmal Putra Fardinansyah, Deni Fajar Fitriyana, Athanasius Priharyoto Bayuseno, Januar Parlaungan Siregar, Muji Setiyo</dc:rights>
</oai_dc:dc>