Akses terbuka
Jurnal
SINTA 1
Experimental performance evaluation of a liquid–gas ejector with a confined suction chamber under vertical downward flow:.
Mechanical Engineering for Society and Industry · Vol. 6 No. 2 (2026)
ISSN 2798-5245
Terbit 2026-09-16
Penerbit Universitas Muhammadiyah Magelang
Bahasa en
Abstrak
A liquid–gas ejector (LGE) is a vacuum-generating device that uses high-pressure liquid to entrain and compress gas and is widely applied in industrial processes. However, undesired recirculation within the suction chamber may reduce entrainment effectiveness and overall ejector performance. This study experimentally investigates the effect of a confined suction chamber on the performance of a vertical downward flow. The modified chamber was designed to restrict the interaction zone between the liquid jet and the surrounding gas, thereby reducing circulation losses. The performance of the confined suction chamber was compared with that of a conventional suction chamber under the same operating conditions by evaluating suction pressure, static pressure distribution, flow ratio, and efficiency. The results show that the confined suction chamber produced lower throat pressure and altered pressure recovery along the throat and diffuser, indicating changes in the entrainment processes. It also delivered higher suction performance and greater maximum efficiency than the conventional configuration. The analysis indicates that, at a flow rate of 0.327 L/s, the confined suction chamber produces a lower absolute pressure of 44 kPa absolute than the conventional suction chamber, which records 54 kPa absolute. The highest efficiency obtained with the confined suction chamber was 9.94% at a flow ratio of 0.82, compared with 8.23% at 0.87 for the conventional chamber.
Jaringan kolaborasi para penulis
14 penulis ·
26 tautan kepenulisan bersama
· 14 lintas organisasi
Arahkan kursor atau ketuk sebuah nama untuk menyorot rekan penulisnya. Klik dua kali untuk membuka halaman penulis.
Muhammadiyah University of Surakarta Mercu Buana University Muhammadiyah University of Yogyakarta Institut Teknologi Nasional Yogyakarta National Taiwan University of Science and Technology University of Sarjanawiyata Tamansiswa
Organisasi berbeda
Organisasi sama
Afiliasi tidak diketahui
Garis lebih tebal = lebih banyak artikel bersama · lingkaran lebih besar = lebih banyak artikel
Tampilkan sebagai tabel
Afiliasi berasal dari OpenAlex; metadata OAI-PMH jurnal tidak memuatnya. Penulis tanpa ID OpenAlex dicocokkan berdasarkan nama, sehingga dua orang bisa tergabung atau satu orang bisa terpisah.
Sumber metadata: OAI-PMH (metadata jurnal) https://journal.unimma.ac.id/index.php/mesi/oai, pertama di-harvest 9 Nov 2026, terakhir terlihat 9 Nov 2026.
Metadata asli (oai_dc)
<oai_dc:dc xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
<dc:title xml:lang="en">Experimental performance evaluation of a liquid–gas ejector with a confined suction chamber under vertical downward flow: .</dc:title>
<dc:creator xml:lang="en">Sugati, Daru</dc:creator>
<dc:creator xml:lang="en">Irawan, Yosua Heru</dc:creator>
<dc:creator xml:lang="en">Effendy, Marwan</dc:creator>
<dc:creator xml:lang="en">Salim, Amat Agus</dc:creator>
<dc:subject xml:lang="en">LGE</dc:subject>
<dc:subject xml:lang="en">Gas entrainment</dc:subject>
<dc:subject xml:lang="en">Conventional suction chamber</dc:subject>
<dc:subject xml:lang="en">Confined suction chamber</dc:subject>
<dc:description xml:lang="en">A liquid–gas ejector (LGE) is a vacuum-generating device that uses high-pressure liquid to entrain and compress gas and is widely applied in industrial processes. However, undesired recirculation within the suction chamber may reduce entrainment effectiveness and overall ejector performance. This study experimentally investigates the effect of a confined suction chamber on the performance of a vertical downward flow. The modified chamber was designed to restrict the interaction zone between the liquid jet and the surrounding gas, thereby reducing circulation losses. The performance of the confined suction chamber was compared with that of a conventional suction chamber under the same operating conditions by evaluating suction pressure, static pressure distribution, flow ratio, and efficiency. The results show that the confined suction chamber produced lower throat pressure and altered pressure recovery along the throat and diffuser, indicating changes in the entrainment processes. It also delivered higher suction performance and greater maximum efficiency than the conventional configuration. The analysis indicates that, at a flow rate of 0.327 L/s, the confined suction chamber produces a lower absolute pressure of 44 kPa absolute than the conventional suction chamber, which records 54 kPa absolute. The highest efficiency obtained with the confined suction chamber was 9.94% at a flow ratio of 0.82, compared with 8.23% at 0.87 for the conventional chamber.</dc:description>
<dc:publisher xml:lang="en">Universitas Muhammadiyah Magelang</dc:publisher>
<dc:date>2026-09-16</dc:date>
<dc:type>info:eu-repo/semantics/article</dc:type>
<dc:type>info:eu-repo/semantics/publishedVersion</dc:type>
<dc:identifier>https://journal.unimma.ac.id/mesi/article/view/15590</dc:identifier>
<dc:identifier>10.31603/mesi.15590</dc:identifier>
<dc:source xml:lang="en">Mechanical Engineering for Society and Industry; Vol. 6 No. 2 (2026): Issue in Progress</dc:source>
<dc:source>2798-5245</dc:source>
<dc:language>en</dc:language>
<dc:rights xml:lang="en">Copyright (c) 2026 Daru Sugati, Yosua Heru Irawan, Marwan Effendy, Amat Agus Salim</dc:rights>
<dc:rights xml:lang="en">http://creativecommons.org/licenses/by-nc/4.0</dc:rights>
</oai_dc:dc>
Sitasi dan pengindeksan
OpenAlex
Terindeks
lewat DOI
0 sitasi
Crossref
Belum diperiksa
Jumlah menurut tiap indeks pada 13 Nov 2026; setiap indeks menghitung sitasi dengan cara berbeda.
OpenAlex juga mencatat karya ini di: crossref.
Sitasi artikel ini
APA 7
Sugati, D., Irawan, Y. H., Effendy, M., & Salim, A. A. (2026). Experimental performance evaluation of a liquid–gas ejector with a confined suction chamber under vertical downward flow:. Mechanical Engineering for Society and Industry, 6(2). https://doi.org/10.31603/mesi.15590
Salin
IEEE
D. Sugati, Y. H. Irawan, M. Effendy, and A. A. Salim, “Experimental performance evaluation of a liquid–gas ejector with a confined suction chamber under vertical downward flow:,” Mechanical Engineering for Society and Industry, vol. 6, no. 2, 2026, doi: 10.31603/mesi.15590.
Salin
Dibuat dari metadata jurnal; periksa nama penulis sebelum dipakai.